BMS System Sample Clauses

BMS System. With the renovation of the building in 2008, a first system for the automation of the systems had already been installed. This was branded "Trend Controls" and provided for a controller in each electrical panel, connected to its probes and relays, with the possibility of communication between the various control units located in the building on a LAN network using proprietary protocol. In order to allow communication between them (in addition to providing internet access to the tenants), a data network was implemented in the condominium, with firewall and central switch in the boiler room and XxX switch for each dwelling. Recently, TECNOZENITH carried out a revamping of the entire BMS system present. A completely new system, branded Swiss Control System, was installed to replace the existing controllers. This new system features significant improvements in performance and thermal system utilization. The new SCS EXD10 controllers feature a native BACnet interface, the open communication protocol developed by the American ASHRAE, which is becoming the most widely used standard in the building management system. However, they are freely programmable, i.e. it is possible to overwrite the regulation strategy at any time, even remotely, from the TECNOZENITH server in Saluzzo, where it is also possible to view and modify the parameters via the internet connection of the Verzuolo building; it is also possible to expand the system by adding the EXD100 expansions (already present in the boiler room), which increases the number of possible controllable points. SCS controllers can interface many protocols used in HVAC systems, such as the KNX, Modbus RTU, BACnet MS-TP or M-bus protocol. Currently, all the controllers installed communicate via Modbus with MID certified electrical meters, to know the consumption of the apartments and the heating system, as well as using the same protocol for interfacing the touch-screen sensor.
AutoNDA by SimpleDocs

Related to BMS System

  • PATROL VIDEO SYSTEMS 2 1. As part of the law enforcement services to be provided to CITY, COUNTY 3 has provided, or will provide, patrol video systems (hereinafter called “PVS”) 4 that are or will be mounted in patrol vehicles designated by COUNTY for 5 use within CITY service area.

  • Computer Equipment Recycling Program If this Contract is for the purchase or lease of computer equipment, then Contractor certifies that it is in compliance with Subchapter Y, Chapter 361 of the Texas Health and Safety Code related to the Computer Equipment Recycling Program and the Texas Commission on Environmental Quality rules in 30 TAC Chapter 328.

  • Unbundled Sub-Loop Concentration System (USLC 2.9.1 Where facilities permit and where necessary to comply with an effective Commission order, BellSouth will provide <<customer_name>> with the ability to concentrate its sub-loops onto multiple DS1s back to the BellSouth Central Office. The DS1s will then be terminated into <<customer_name>>’s collocation space. TR-008 and TR303 interface standards are available.

  • Interconnection Product Options Interconnection Customer has selected the following (checked) type of Interconnection Service:

  • Access to Network Interface Device (NID 2.4.3.1. Due to the wide variety of NIDs utilized by BellSouth (based on subscriber size and environmental considerations), Mpower may access the on-premises wiring by any of the following means: BellSouth shall allow Mpower to connect its loops directly to BellSouth’s multi-line residential NID enclosures that have additional space and are not used by BellSouth or any other telecommunications carriers to provide service to the premise. Mpower agrees to install compatible protectors and test jacks and to maintain the protection system and equipment and to indemnify BellSouth pursuant to Section 8 of the General Terms and Conditions of this Agreement.

  • School Improvement Plan As permitted under IC § 20-10.2-3-1.5, the Charter shall serve as the Charter School's strategic and continuous school improvement and achievement plan (hereafter, the "School Improvement Plan"). To the extent that IC § 20-10.2 applies to the Charter in its function as the School Improvement Plan, the Organizer shall comply with the requirements under IC § 20-10.2.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • School Improvement Plans The School shall develop and implement a School Improvement Plan as required by section 1002.33(9)(n), Florida Statutes and applicable State Board of Education Rules or applicable federal law.

  • Curriculum Work Service on a District curriculum committee shall be required for grade level or department chairpersons. All other teachers working on such committee(s) shall be designated (in writing) by the Curriculum Director and shall be paid, at the hourly rate contained in Schedule B, for all documented hours of committee service (up to such limits as may be imposed by the District) occurring when school is not in session (e.g. during the summer), during duty-free lunch periods or preparation periods, and before/after the teacher’s regularly scheduled work day. Curriculum committee work shall occur at such times as are determined or approved by the Curriculum Director.

  • Interconnection Customer Interconnection Facilities Interconnection Customer shall design, procure, construct, install, own and/or control Interconnection Customer Interconnection Facilities described in Appendix A, Interconnection Facilities, Network Upgrades and Distribution Upgrades, at its sole expense.

Time is Money Join Law Insider Premium to draft better contracts faster.