Cable Bolting Sample Clauses

Cable Bolting. Cable bolting shall be carried out in accordance with the Drawings and as directed by the Company. Cable bolts shall consist of single 15.2mm low relaxation high tensile 7 wire strands with each cable bolt having an ultimate capacity of 250kn. Bulbs shall be formed on the strands at a density of two bulbs per metre. The cable bolts shall be fitted with 300mm x 300mm x 10mm square black flat bearing plates. These flat plates shall be tensioned with flat barrel and wedges. Each cable bolt shall be grouted in position using an air free, flowable mix, plain water cement grout with a water/cement ratio as low as possible (but between 0.35 and 0.40) and providing a grout strength of not less than 25 MPa after 24 days. Cement shall be Portland Grade A cement. Grout installation shall be in accordance with the manufacturer’s instructions using suitable equipment to force in a consistent grout mixture to completely fill all surrounding cavities. The grouting method, materials and equipment used by the Contractor shall be subject to prior approval by the Company. Prior to cable bolt installation and grouting, drill holes and bolts shall be thoroughly cleaned of all debris. Portland Cement grout shall be allowed to cure for a minimum period of 24 hours and cable bolts plated and tensioned before firing is carried out with in three cuts of the installed cable bolts. Tensioning of cable bolts shall only take place after grout has set and shall only be carried out using suitable approved equipment.
AutoNDA by SimpleDocs

Related to Cable Bolting

  • Telecommunications Services Tenant will contract directly with third party providers and will be solely responsible for paying for all telephone, data transmission, video and other telecommunication services (“Telecommunication Services”) subject to the following:

  • Telecommunications Each Lender and Administrative Agent shall be entitled to rely on the authority of any individual making any telecopy, electronic or telephonic notice, request, or signature without the necessity of receipt of any verification thereof.

  • Electric N/A Electric from Clark from PP6 to DCU-843 2 N/A ------------------------------------------------------------------------------------------------------------------ N/A Electric from Clark from PP6 to Feed Tanks 4 N/A ------------------------------------------------------------------------------------------------------------------ ------------------------------------------------------------------------------------------------------------------

  • ELECTRICAL SERVICES A. Landlord shall provide electric power for a combined load of 3.0 xxxxx per square foot of useable area for lighting and for office machines through standard receptacles for the typical office space.

  • Personal Services The Member shall not be required to perform services for the Company solely by virtue of being a Member.

  • SPECIAL SERVICES Should the Trust have occasion to request the Adviser to perform services not herein contemplated or to request the Adviser to arrange for the services of others, the Adviser will act for the Trust on behalf of the Fund upon request to the best of its ability, with compensation for the Adviser's services to be agreed upon with respect to each such occasion as it arises.

  • FUND ADMINISTRATION SERVICES BNY Mellon shall provide the following fund administration services for each Fund, Series and class:  Calculate Fund approved income and per share amounts required for periodic distributions to be made by the applicable Fund, Series or class;  Coordinate a Fund’s annual audit and respond timely and completely to related requests;  Cooperate with each Fund’s independent auditors;  Supply various normal and customary portfolio and Fund statistical data as requested on an ongoing basis; and  If the chief executive officer or chief financial officer of a Fund is required to provide a certification as part of the Fund’s Form N-Q or Form N-CSR filing pursuant to regulations promulgated by the SEC under Section 302 of the Xxxxxxxx-Xxxxx Act of 2002, provide a sub-certification in support of certain matters set forth in the aforementioned certification. Such sub-certification is to be in such form and relating to such matters as reasonably agreed to by BNY Mellon in advance. BNY Mellon shall be required to provide the sub-certification only during the term of this Agreement with respect to the applicable Fund or Series and only if it receives such cooperation as it may request to perform its investigations with respect to the sub-certification. For clarity, the sub-certification is not itself a certification under the Xxxxxxxx-Xxxxx Act of 2002 or under any other law, rule or regulation. REGULATORY ADMINISTRATION SERVICES BNY Mellon shall provide the following regulatory administration services for each Fund and Series:  Assist the Fund in responding to SEC examination requests by providing requested documents in the possession of BNY Mellon that are on the SEC examination request list and by making employees responsible for providing services available to regulatory authorities having jurisdiction over the performance of such services as may be required or reasonably requested by such regulatory authorities;  Assist with and/or coordinate such other filings, notices and regulatory matters and other due diligence requests or requests for proposal on such terms and conditions as BNY Mellon and the applicable Fund on behalf of itself and its Series may mutually agree upon in writing from time to time; and

  • TELEPHONE SERVICES All telegraph, telephone, and communication connections which Tenant may desire outside the Premises shall be subject to Landlord’s prior written approval, in Landlord’s sole discretion, and the location of all wires and the work in connection therewith shall be performed by contractors approved by Landlord and shall be subject to the direction of Landlord, except that such approval is not required as to Tenant’s cabling from the Premises in a route designated by Landlord to any telephone cabinet or panel provided for Tenant’s connection to the telephone cable serving the Building, so long as Tenant’s equipment does not require connections different than or additional to those to the telephone cabinet or panel provided. As to any such connections or work outside the Premises requiring Landlord’s approval, Landlord reserves the right to designate and control the entity or entities providing telephone or other communication cable installation, removal, repair and maintenance outside the Premises and to restrict and control access to telephone cabinets or panels. In the event Landlord designates a particular vendor or vendors to provide such cable installation, removal, repair and maintenance for the Building, Tenant agrees to abide by and participate in such program. Tenant shall be responsible for and shall pay all costs incurred in connection with the installation of telephone cables and communication wiring in the Premises, including any hook-up, access and maintenance fees related to the installation of such wires and cables in the Premises and the commencement of service therein, and the maintenance thereafter of such wire and cables; and there shall be included in Operating Expenses for the Building all installation, removal, hook-up or maintenance costs incurred by Landlord in connection with telephone cables and communication wiring serving the Building which are not allocable to any individual users of such service but are allocable to the Building generally. If Tenant fails to maintain all telephone cables and communication wiring in the Premises and such failure affects or interferes with the operation or maintenance of any other telephone cables or communication wiring serving the Building, Landlord or any vendor hired by Landlord may enter into and upon the Premises forthwith and perform such repairs, restorations or alterations as Landlord deems necessary in order to eliminate any such interference (and Landlord may recover from Tenant all of Landlord’s costs in connection therewith). No later than the Termination Date, Tenant agrees to remove all telephone cables and communication wiring installed by Tenant for and during Tenant’s occupancy, which Landlord shall request Tenant to remove. Tenant agrees that neither Landlord nor any of its agents or employees shall be liable to Tenant, or any of Tenant’s employees, agents, customers or invitees or anyone claiming through, by or under Tenant, for any damages, injuries, losses, expenses, claims or causes of action because of any interruption, diminution, delay or discontinuance at any time for any reason in the furnishing of any telephone or other communication service to the Premises and the Building.

  • Telephone E-mail: Capitalized terms used but not defined herein have the meanings assigned thereto in the Trust and Servicing Agreement.

  • Electrical Service Subject to the limitation of this Paragraph 4, furnish electrical service to the Premises, including providing and installing all Building standard replacement lighting tubes. If Tenant uses more electrical power than Landlord in good faith considers reasonable or normal for office use, Tenant will pay Landlord on a monthly basis the cost of such excess power consumed by Tenant. Consumption will be determined, at Landlord’s election, either (a) by a survey performed by a reputable consultant selected by Landlord, or (b) through separate meters or submeters installed, maintained and read by Landlord at Tenant’s cost. For purposes of this Paragraph 4 only, “month” and “monthly” shall mean any billing period used by the utility or other power provider supplying electricity. All installations of electrical futures, appliances and equipment within the Premises shall be subject to Landlord’s prior approval, and if they affect the temperature or humidity otherwise maintained, Landlord may, at Tenant’s sole cost and expense (to be paid within (30) days after delivery of written demand supported by invoices or other reasonably satisfactory evidence), install supplemental air conditioning units. Tenant’s use of electricity shall never exceed Tenant’s share of the capacity of existing feeders to the Building or of the risers, wiring installations and transformers serving the floor(s) containing the Premises. Landlord shall provide up to 3.5 xxxxx per usable square foot (demand) of riser and floor panel electrical capacity averaged over the floor being serviced. EXHIBIT C Tenant shall be allocated an approximate 2.0 xxxxx per usable square foot for power and 1.5 xxxxx per usable square foot for lighting. Any risers or wiring necessary to meet Tenant’s excess electrical requirements will be installed by Landlord on Tenant’s request, at Tenant’s sole cost and expense (to be paid in advance), but only if in Landlord’s reasonable good faith belief they are necessary and will not cause damage to the Building or a dangerous condition, entail excessive or unreasonable alterations, repairs or expense, or disturb other occupants.

Time is Money Join Law Insider Premium to draft better contracts faster.