Cable requirements Sample Clauses

Cable requirements. The cables shall comply with the relevant standard and bear the relevant rating such as TC-ER for the North American version. • The trunk cable conductors shall be color coded appropriately: US Black Red Blue White Green or Green/Yellow EU Xxxxx Black Grey Blue Green/Yellow • The Drop cable can optionally use the same color code as the Trunk cable. If uniform color is used, such as all black, markings shall be added to identify the conductor number • The cable shall be flexible. The minimum bend radius shall be 10 times the cable outside diameter. • The wire arrangement shall be as such: 4 conductor (future) X0 XX X0 X 3 conductor (future) — XX X0 N • Minimum wire gauges shall be 12 AWG and 18 AWG for the trunk and drop wires respectively.
AutoNDA by SimpleDocs
Cable requirements. Charging Cable Assembly: As per Section 10 of AIS 138 Part 2, with the functional characteristics defined as below: a) Functional characteristics: The maximum cord length will be 5 meter, straight cable b) Cable Connection Type: supply cable will be with EVSE as per Case C defined in section 6.3.1 of IEC61851-1.
Cable requirements drop locations throughout the building. Your proposal should include the needed time and labor to review the building site and note where the drops need be installed. o The City has selected a single equipment closet to be used for termination of the new cable. o The selected closet exists today and is on the second floor of the City Hall building. o Work shall include the following components for each of the 40 drop locations:
Cable requirements. Flame retardant armored cables shall be overall and individual shielded as specified. Fire resistant armored cables shall be overall shielded as specified. Cables shall be overall shielded with drain wire for the following cases: a. Gas detector signals (if not 4 – 20 mA) b. Fire detector signals (if not 4 – 20 mA) Cables shall be twisted pair shielded and overall shielded with drain wire for following cases: a. Signals Cables (4 – 20 mA) b. mV or resistance cables c. frequency signals (e.g. flowmeters) d. Vibration signals (if not 4 – 20 mA) e. All other MCM low voltage signals Cables shall be overall shielded with drain wire for following cases: a. Use for 24 VDC b. Telephone Cables shall be without any shielding for Solenoid Valves.

Related to Cable requirements

  • Vehicle Requirements The following shall be considered minimum Vehicle requirements. The Authorized User shall include supplemental required specifications for Vehicles specified in a Mini-Bid. Unless otherwise indicated, all items specified which are listed on the OEM Pricelist as standard or optional equipment shall be factory installed and operative. Vehicles delivered to an Authorized User in a condition considered to be below retail customer acceptance levels will not be accepted. Items which determine this acceptance level shall include, but not be limited to, the general appearance of the interior and exterior of the vehicle for completeness and quality of workmanship, lubrication and fluid levels, with any leaks corrected, mechanical operation of the vehicle and all electrical components operational. Product specified to be furnished and installed which is not available through the OEM shall conform to the standards known to that particular industry, both product and installation.

  • Lessee's Compliance with Applicable Requirements Except as otherwise provided in this Lease, Lessee shall, at Lessee's sole expense, fully, diligently and in a timely manner, materially comply with all Applicable Requirements, the requirements of any applicable fire insurance underwriter or rating bureau, and the recommendations of Lessor's engineers and/or consultants which relate in any manner to the Premises, without regard to whether said requirements are now in effect or become effective after the Start Date. Lessee shall, within ten (10) days after receipt of Lessor's written request, provide Lessor with copies of all permits and other documents, and other information evidencing Lessee's compliance with any Applicable Requirements specified by Lessor, and shall immediately upon receipt, notify Lessor in writing (with copies of any documents involved) of any threatened or actual claim, notice, citation, warning, complaint or report pertaining to or involving the failure of Lessee or the Premises to comply with any Applicable Requirements.

  • Compliance with Applicable Requirements In carrying out its obligations under this Agreement, the Sub-Adviser shall at all times comply with: (a) all applicable provisions of the 1940 Act, and any rules and regulations adopted thereunder; (b) the provisions of the registration statement of the Trust, as it may be amended or supplemented from time to time, under the Securities Act and the 1940 Act; (c) the provisions of the Declaration of Trust of the Trust, as it may be amended or supplemented from time to time; (d) the provisions of any By-laws of the Trust, if adopted and as it may be amended from time to time, or resolutions of the Board as may be adopted from time to time; (e) the provisions of the Internal Revenue Code of 1986, as amended, applicable to the Trust or the Funds; (f) any other applicable provisions of state or federal law; and In addition, any code of ethics adopted by the Sub-Adviser must comply with Rule 17j-1 under the 1940 Act, as it may be amended from time to time, and any broadly accepted industry practices, if requested by the Trust or the Adviser.

  • Conformance to Applicable Requirements All work prepared by Consultant shall be subject to the approval of City.

  • Time Requirements The Independent Contractor will not be required to follow or establish a regular or daily work schedule, but shall devote during the term of this Agreement the time, energy and skill as necessary to perform the services of this engagement and shall, periodically or at any time upon the request of the Company, submit information as to the amount of time worked and scope of work performed.

  • Quality Assurance Requirements There are no special Quality Assurance requirements under this Agreement.

  • Interface Requirements 2.4.5.1 The NID shall be equal to or better than all of the requirements for NIDs set forth in the applicable industry standard technical references.

  • Access Requirements You will be responsible for providing the System to enable you to use an Electronic Service.

  • Software Requirements 7 Developer shall prepare the Project Schedule using Oracle’s Primavera P6.

  • Contractor Requirements The Firm shall be construed, during the entire term of this contract, to be an independent contractor. Nothing in this contract is intended to nor shall be construed to create an employer- employee relationship, or a joint venture relationship. The Firm represents that it is qualified to perform the duties to be performed under this contract and that it has, or will secure, if needed, at its own expense, applicable personnel who are qualified to perform the duties required under this contract. Such personnel shall not be deemed in any way, directly or indirectly, expressly or by implication, to be employees of the District. Any person assigned by the firm to perform the services hereunder shall be the employee or a subcontractor of the Firm, who shall have the sole right to hire and discharge its employee or subcontractors. The Firm or its subcontractors shall pay, when due, all salaries and wages of their employees and accepts exclusive responsibility for the payment of federal income tax, social security, unemployment compensation and any other withholdings that may be required. Neither the Firm, its subcontractors nor their employees are entitled to state retirement or leave benefits. It is further understood that the consideration expressed herein constitutes full and complete compensation for all services and performance hereunder, and that any sum due and payable to the Firm shall be paid as a gross sum with no withholdings or deductions being made by the District for any purpose from said contract sum, except as permitted in paragraphs 16, 17 and 18.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!