Capacity Multiplier Sample Clauses

Capacity Multiplier. The capacity multiplier shall be the greater of 1 or the multiplier arrived at by applying the following formula: M(1) = 1 + [0.6[BTUH/33-1]]
AutoNDA by SimpleDocs
Capacity Multiplier. M1 The Capacity Multiplier, M1, is an adjusting multiplier to the Minimum Cooling Charge to account for an installed cooling capacity greater than the Design Criteria of 36 BTU/Hr-Sq Ft of Floor Area in accordance with Exhibit C. M1 shall be the greater of 1 or the multiplier derived by applying the following formula: M1 = 1 + 0.69 x [(BTU/36) - 1]

Related to Capacity Multiplier

  • Power Factor The Power Producer shall maintain the Power Factor as per the prevailing GERC regulations and as may be stipulated / specified by GETCO from time to time. The Power Producer shall provide suitable protection devices, so that the Electric Generators could be isolated automatically when grid supply fails. Connectivity criteria like short circuit level (for switchgear), neutral Grounding, fault clearance time, current unbalance (including negative and zero sequence currents), limit of harmonics etc. shall be as per Grid Code.

  • FREQUENCY AND CAPACITY LEVELS No restriction on frequency, capacity or aircraft type.

  • Maximum Leverage Permit, as of any fiscal quarter end, the ratio of (a) Adjusted Portfolio Equity as of such fiscal quarter end to (b) Funded Debt as of such fiscal quarter end, to be less than 5.00 to 1.00.

  • PERCENTAGE GOAL The goal for Historically Underutilized Business (HUB) participation in the work to be performed under this contract is 23.7 % of the contract amount.

  • Adjustment of Minimum Quarterly Distribution and Target Distribution Levels (a) The Minimum Quarterly Distribution, First Target Distribution, Second Target Distribution, Third Target Distribution, Common Unit Arrearages and Cumulative Common Unit Arrearages shall be proportionately adjusted in the event of any distribution, combination or subdivision (whether effected by a distribution payable in Units or otherwise) of Units or other Partnership Securities in accordance with Section 5.10. In the event of a distribution of Available Cash that is deemed to be from Capital Surplus, the then applicable Minimum Quarterly Distribution, First Target Distribution, Second Target Distribution and Third Target Distribution, shall be adjusted proportionately downward to equal the product obtained by multiplying the otherwise applicable Minimum Quarterly Distribution, First Target Distribution, Second Target Distribution and Third Target Distribution, as the case may be, by a fraction of which the numerator is the Unrecovered Capital of the Common Units immediately after giving effect to such distribution and of which the denominator is the Unrecovered Capital of the Common Units immediately prior to giving effect to such distribution. (b) The Minimum Quarterly Distribution, First Target Distribution, Second Target Distribution and Third Target Distribution, shall also be subject to adjustment pursuant to Section 6.9.

  • Number Resources, Rate Center Areas and Routing Points 8.1 Nothing in this Agreement shall be construed to limit or otherwise adversely affect in any manner either Party’s right to employ or to request and be assigned any Central Office Codes (“NXX”) pursuant to the Central Office Code Assignment Guidelines and any relevant FCC or Commission orders, as may be amended from time to time, or to establish, by Tariff or otherwise, Rate Center Areas and Routing Points corresponding to such NXX codes. 8.2 It shall be the responsibility of each Party to program and update its own switches and network systems pursuant to information provided in the LERG in order to recognize and route traffic to the other Party’s assigned NXX codes. Except as expressly set forth in this Agreement, neither Party shall impose any fees or charges whatsoever on the other Party for such activities. 8.3 Unless otherwise required by Commission order, the Rate Center Areas will be the same for each Party. During the term of this Agreement, Onvoy shall adopt the Rate Center Area and Rate Center Points that the Commission has approved for Frontier within the LATA and Tandem serving area. Onvoy shall assign whole NPA-NXX codes to each Rate Center Area unless otherwise ordered by the FCC, the Commission or another governmental entity of appropriate jurisdiction, or the LEC industry adopts alternative methods of utilizing NXXs. 8.4 Onvoy will also designate a Routing Point for each assigned NXX code. Onvoy shall designate one location for each Rate Center Area in which the Onvoy has established NXX code(s) as the Routing Point for the NPA-NXXs associated with that Rate Center Area, and such Routing Point shall be within the same LATA as the Rate Center Area but not necessarily within the Rate Center Area itself. Unless specified otherwise, calls to subsequent NXXs of Onvoy will be routed in the same manner as calls to Xxxxx’s initial NXXs. 8.5 Notwithstanding anything to the contrary contained herein, nothing in this Agreement is intended, and nothing in this Agreement shall be construed, to in any way constrain Onvoy’s choices regarding the size of the local calling area(s) that Onvoy may establish for its Customers, which local calling areas may be larger than, smaller than, or identical to Frontier’s local calling areas.

  • Power Factor Design Criteria Developer shall design the Large Generating Facility to maintain an effective power delivery at demonstrated maximum net capability at the Point of Interconnection at a power factor within the range established by the Connecting Transmission Owner on a comparable basis, until NYISO has established different requirements that apply to all generators in the New York Control Area on a comparable basis. The Developer shall design and maintain the plant auxiliary systems to operate safely throughout the entire real and reactive power design range. The Connecting Transmission Owner shall not unreasonably restrict or condition the reactive power production or absorption of the Large Generating Facility in accordance with Good Utility Practice.

  • Measurement method An isolation resistance test instrument is connected between the live parts and the electrical chassis. The isolation resistance is subsequently measured by applying a DC voltage at least half of the working voltage of the high voltage bus. If the system has several voltage ranges (e.g. because of boost converter) in conductively connected circuit and some of the components cannot withstand the working voltage of the entire circuit, the isolation resistance between those components and the electrical chassis can be measured separately by applying at least half of their own working voltage with those components disconnected.

  • Maximum or Minimum Interest Rate If specified on the face hereof, this Note may have either or both of a Maximum Interest Rate or a Minimum Interest Rate. If a Maximum Interest Rate is so designated, the interest rate for a Floating Rate Note cannot ever exceed such Maximum Interest Rate and in the event that the interest rate on any Interest Reset Date would exceed such Maximum Interest Rate (as if no Maximum Interest Rate were in effect) then the interest rate on such Interest Reset Date shall be the Maximum Interest Rate. If a Minimum Interest Rate is so designated, the interest rate for a Floating Rate Note cannot ever be less than such Minimum Interest Rate and in the event that the interest rate on any Interest Reset Date would be less than such Minimum Interest Rate (as if no Minimum Interest Rate were in effect) then the interest rate on such Interest Reset Date shall be the Minimum Interest Rate. Notwithstanding anything to the contrary contained herein, the interest rate on a Floating Rate Note shall not exceed the maximum interest rate permitted by applicable law.

  • Points The points to be assigned to the classification levels under this Agreement shall be: C14 - C13 - C12 32 C11 64 C10 96 C9 12 additional points above C10 C8 24 additional points above C10 C7 36 additional points above C10 C6 48 additional points above C10 C5 60 additional points above C10 C4 Standards and points to be finalised C3 Standards and points to be finalised C2a Standards and points to be finalised C2b Standards and points to be finalised C1a Standards and points to be finalised C1b Standards and points to be finalised and in accordance with Table 2 in the National Metal and Engineering Competency Standards Implementation Guide.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!