CFP4 Mechanical Surface Characteristics. The mechanical surface of flat top CFP4 module which may be in contact with the host riding heat sink assembly shall be compliant with specifications in Table 5-1. The parameters listed in Table 5-1 define the CFP4 module thermal interface and may be used by host system designers to specify the host cage assembly opening and riding heat sink for optimizing host system thermal management performance. Surface flatness and roughness parameters are specified per CFP4 module power class (see Table 4-1) to allow for optimization of module thermal performance and cost. Non-compliance to these specifications may cause significant thermal performance degradation. Only the top surface of the module is assumed to be used for heat transfer. Weight 1 – 6 90 g Flatness 1 0.15 mm 2 0.15 mm 3 0.12 mm 4 0.12 mm Roughness 1 3.2 Ra 3 1.6 Ra Temperature Delta 1 - 4 7 °C No heat sink; 200 lfm sideways airflow Normal force exerted on module 1 - 4 5 15 N Heat sink on module top surface
AutoNDA by SimpleDocs
CFP4 Mechanical Surface Characteristics. The mechanical surface of flat top CFP4 module which may be in contact with the host riding heat sink assembly shall be compliant with specifications in Table 5-1. The parameters listed in Table 5-1 define the CFP4 module thermal interface and may be used by host system designers to specify the host cage assembly opening and riding heat sink for optimizing host system thermal management performance. Surface flatness and roughness parameters are specified per CFP4 module power class (see Table 4-1) to allow for optimization of module thermal performance and cost. Non-compliance to these specifications may cause significant thermal performance degradation. Only the top surface of the module is assumed to be used for heat transfer. Weight 1 – 6 90 g Flatness 1 0.15 mm 3 0.12 mm 4 0.12 mm Roughness 1 3.2 Ra

Related to CFP4 Mechanical Surface Characteristics

  • Pool Characteristics The Mortgage Loans in the related Mortgage Loan Package have the characteristics as set forth on Exhibit 2 to the related Assignment and Conveyance.

  • Underground Tanks If underground or other storage tanks storing Hazardous Materials located on the Premises or the Project are used by Tenant or are hereafter placed on the Premises or the Project by Tenant, Tenant shall install, use, monitor, operate, maintain, upgrade and manage such storage tanks, maintain appropriate records, obtain and maintain appropriate insurance, implement reporting procedures, properly close any underground storage tanks, and take or cause to be taken all other actions necessary or required under applicable state and federal Legal Requirements, as such now exists or may hereafter be adopted or amended in connection with the installation, use, maintenance, management, operation, upgrading and closure of such storage tanks.

  • CHARACTERISTICS OF THE ACADEMY The characteristics of the Academy set down in Section 1(6) of the Academies Act 2010, are that:

  • REPAIRED OR REPLACED PARTS / COMPONENTS Where the Contractor is required to repair, replace or substitute Product or parts or components of the Product under the Contract, the repaired, replaced or substituted Products shall be subject to all terms and conditions for new parts and components set forth in the Contract including Warranties, as set forth in the Additional Warranties Clause herein. Replaced or repaired Product or parts and components of such Product shall be new and shall, if available, be replaced by the original manufacturer’s component or part. Remanufactured parts or components meeting new Product standards may be permitted by the Commissioner or Authorized User. Before installation, all proposed substitutes for the original manufacturer’s installed parts or components must be approved by the Authorized User. The part or component shall be equal to or of better quality than the original part or component being replaced.

  • ODUF Physical File Characteristics 6.2.1 ODUF will be distributed to TWTC via Secure File Transfer Protocol (FTP). The ODUF feed will be a variable block format. The data on the ODUF feed will be in a non-compacted EMI format (175 byte format plus modules). It will be created on a daily basis Monday through Friday except holidays. Details such as dataset name and delivery schedule will be addressed during negotiations of the distribution medium. There will be a maximum of one dataset per workday per OCN. If AT&T determines the Secure FTP Mailbox is nearing capacity levels, AT&T may move the customer to CONNECT: Direct file delivery. 6.2.2 If the customer is moved, CONNECT: Direct data circuits (private line or dial-up) will be required between AT&T and TWTC for the purpose of data transmission. Where a dedicated line is required, TWTC will be responsible for ordering the circuit, overseeing its installation and coordinating the installation with AT&T. TWTC will also be responsible for any charges associated with this line. Equipment required on the AT&T end to attach the line to the mainframe computer and to transmit messages successfully on an ongoing basis will be negotiated on an individual case basis. Any costs incurred for such equipment will be TWTC's responsibility. Where a dial-up facility is required, dial circuits will be installed in the AT&T data center by AT&T and the associated charges assessed to TWTC. Additionally, all message toll charges associated with the use of the dial circuit by TWTC will be the responsibility of TWTC. Associated equipment on the AT&T end, including a modem, will be negotiated on an individual case basis between the Parties. All equipment, including modems and software, that is required on TWTC end for the purpose of data transmission will be the responsibility of TWTC. 6.2.3 If TWTC utilizes FTP for data file transmission, purchase of the FTP software will be the responsibility of TWTC.

  • Characteristics The Contracts have the following characteristics: (i) all the Contracts are secured by Motorcycles; (ii) no Contract has a remaining maturity of more than 84 months; and (iii) the final scheduled payment on the Contract with the latest maturity is due no later than July 27, 2030. Approximately 63.90% of the Pool Balance as of the Cutoff Date is attributable to loans for purchases of new Motorcycles and approximately 36.10% is attributable to loans for purchases of used Motorcycles. No Contract was originated after the Cutoff Date. No Contract has a Contract Rate less than 0.010%.

  • Physical File Characteristics 7.2.1 The EODUF feed will be distributed to Comcast Phone over their existing Optional Daily Usage File (ODUF) feed. The EODUF messages will be intermingled among Comcast Phone’s Optional Daily Usage File (ODUF) messages. The EODUF will be a variable block format (2476) with an LRECL of 2472. The data on the EODUF will be in a non-compacted EMI format (175 byte format plus modules). It will be created on a daily basis (Monday through Friday except holidays). 7.2.2 Data circuits (private line or dial-up) may be required between BellSouth and Comcast Phone for the purpose of data transmission. Where a dedicated line is required, Comcast Phone will be responsible for ordering the circuit, overseeing its installation and coordinating the installation with BellSouth. Comcast Phone will also be responsible for any charges associated with this line. Equipment required on the BellSouth end to attach the line to the mainframe computer and to transmit successfully ongoing will be negotiated on an individual case basis. Where a dial-up facility is required, dial circuits will be installed in the BellSouth data center by BellSouth and the associated charges assessed to Comcast Phone. Additionally, all message toll charges associated with the use of the dial circuit by Comcast Phone will be the responsibility of Comcast Phone. Associated equipment on the BellSouth end, including a modem, will be negotiated on an individual case basis between the Parties. Version 4Q01 12/01/01 All equipment, including modems and software, that is required on Comcast Phone’s end for the purpose of data transmission will be the responsibility of Comcast Phone.

  • Substance Abuse Testing The Parties agree that it is in the best interest of all concerned to promote a safe working environment. The Union has no objection to pre-employment substance abuse testing when required by the Employer and further, the Union has no objection to voluntary substance abuse testing to qualify for employment on projects when required by a project owner. The cost and scheduling of such testing shall be paid for and arranged by the Employer. The Union agrees to reimburse the Employer for any failed pre-access Alcohol and Drug test costs.

  • Meter Testing Company shall provide at least twenty-four (24) hours' notice to Seller prior to any test it may perform on the revenue meters or metering equipment. Seller shall have the right to have a representative present during each such test. Seller may request, and Company shall perform, if requested, tests in addition to the every fifth-year test and Seller shall pay the cost of such tests. Company may, in its sole discretion, perform tests in addition to the fifth year test and Company shall pay the cost of such tests. If any of the revenue meters or metering equipment is found to be inaccurate at any time, as determined by testing in accordance with this Section 10.2 (Meter Testing), Company shall promptly cause such equipment to be made accurate, and the period of inaccuracy, as well as an estimate for correct meter readings, shall be determined in accordance with Section 10.3 (Corrections).

  • Meteorological Data Reporting Requirement (Applicable to wind generation facilities only)

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!