Constructive characteristics Sample Clauses

Constructive characteristics. Generally, zinc oxide (ZnO) dischargers will be supplied for minimum class 2 external installation for 138 kV, class 4 for 220 kV and class 5 for 500 kV. They will be suitable for equipment protection against atmospheric surges and switching surges. The permanent current must return to a constant non-increasing value after dissipation of the transient produced by a discharge. Arresters shall be suitable for systems with solidly grounded neutral, and the residual voltage of impulse currents shall be as low as possible. There should be no corona discharge. Sharp points in terminals or ends must be adequately shielded by the use of anti-corona rings in order to comply with the requirements of radio interference and corona effect. The resistive unit material will be zinc oxide, and each discharger may consist of one or more units, each of which must be a discharger itself. They will be provided with discharge counters.
AutoNDA by SimpleDocs
Constructive characteristics. Generally shall be supplied dischargers of Zinc Oxide (ZnO) for external installation, class 2. They will be adequate for the protection of equipment against atmospheric overvoltages and maneuver overvoltages. The permanent current should return to a constant not-increasing value after the transient dissipation produced by a discharge. The dischargers will be suitable for systems with neutral solid grounding; the residual voltage of currents of impulse should be the lowest possible. It shall not present discharges for crown effect. The sharp points in terminals or ends shall be properly shielded through the use of anticrown rings, to comply with the requirements of radio interference and crown effect. The material of the resistive unit will be Zinc Oxide, and each discharger may be constituted by one or several units, and each one of them shall be a discharger. They should be provided of discharge counters.

Related to Constructive characteristics

  • Individual Characteristics Each Receivable has the following individual characteristics as of the Cut-Off Date: (i) each Receivable is secured by a new or used automobile, minivan or sport utility vehicle; (ii) each Receivable has an APR of no less than 0.00% and not more than 13.94; (iii) each Receivable had an original term to maturity of not more than 72 months and not less than 18 months and each Receivable has a remaining term to maturity, as of the Cut-Off Date, of 12 months or more; (iv) each Receivable has an Outstanding Principal Balance as of the Cut-Off Date of greater than or equal to $2,394.67; (v) no Receivable has a scheduled maturity date later than October 7, 2020; (vi) no Receivable was more than 30 days past due as of the Cut-Off Date; (vii) as of the Cut-off Date, no Receivable was noted in the records of VCI or the Servicer as being the subject of any pending bankruptcy or insolvency proceeding; (viii) no Receivable is subject to a force-placed Insurance Policy on the related Financed Vehicle; (ix) each Receivable is a Simple Interest Receivable; (x) each of the Receivables were selected using selection procedures that were not known or intended by VCI or the Servicer to be adverse to the Purchaser; and (xi) the Dealer of the Financed Vehicle has no participation in, or other right to receive, any proceeds of such Receivable.

  • Pool Characteristics The Mortgage Loans in the related Mortgage Loan Package have the characteristics as set forth on Exhibit 2 to the related Assignment and Conveyance.

  • Characteristics The Contracts have the following characteristics: (i) all the Contracts are secured by Motorcycles; (ii) no Contract has a remaining maturity of more than 84 months; and (iii) the final scheduled payment on the Contract with the latest maturity is due no later than July 27, 2030. Approximately 63.90% of the Pool Balance as of the Cutoff Date is attributable to loans for purchases of new Motorcycles and approximately 36.10% is attributable to loans for purchases of used Motorcycles. No Contract was originated after the Cutoff Date. No Contract has a Contract Rate less than 0.010%.

  • Physical File Characteristics 7.2.1 The EODUF feed will be distributed to Comcast Phone over their existing Optional Daily Usage File (ODUF) feed. The EODUF messages will be intermingled among Comcast Phone’s Optional Daily Usage File (ODUF) messages. The EODUF will be a variable block format (2476) with an LRECL of 2472. The data on the EODUF will be in a non-compacted EMI format (175 byte format plus modules). It will be created on a daily basis (Monday through Friday except holidays). 7.2.2 Data circuits (private line or dial-up) may be required between BellSouth and Comcast Phone for the purpose of data transmission. Where a dedicated line is required, Comcast Phone will be responsible for ordering the circuit, overseeing its installation and coordinating the installation with BellSouth. Comcast Phone will also be responsible for any charges associated with this line. Equipment required on the BellSouth end to attach the line to the mainframe computer and to transmit successfully ongoing will be negotiated on an individual case basis. Where a dial-up facility is required, dial circuits will be installed in the BellSouth data center by BellSouth and the associated charges assessed to Comcast Phone. Additionally, all message toll charges associated with the use of the dial circuit by Comcast Phone will be the responsibility of Comcast Phone. Associated equipment on the BellSouth end, including a modem, will be negotiated on an individual case basis between the Parties. Version 4Q01 12/01/01 All equipment, including modems and software, that is required on Comcast Phone’s end for the purpose of data transmission will be the responsibility of Comcast Phone.

  • ODUF Physical File Characteristics 6.2.1 ODUF will be distributed to TWTC via Secure File Transfer Protocol (FTP). The ODUF feed will be a variable block format. The data on the ODUF feed will be in a non-compacted EMI format (175 byte format plus modules). It will be created on a daily basis Monday through Friday except holidays. Details such as dataset name and delivery schedule will be addressed during negotiations of the distribution medium. There will be a maximum of one dataset per workday per OCN. If AT&T determines the Secure FTP Mailbox is nearing capacity levels, AT&T may move the customer to CONNECT: Direct file delivery. 6.2.2 If the customer is moved, CONNECT: Direct data circuits (private line or dial-up) will be required between AT&T and TWTC for the purpose of data transmission. Where a dedicated line is required, TWTC will be responsible for ordering the circuit, overseeing its installation and coordinating the installation with AT&T. TWTC will also be responsible for any charges associated with this line. Equipment required on the AT&T end to attach the line to the mainframe computer and to transmit messages successfully on an ongoing basis will be negotiated on an individual case basis. Any costs incurred for such equipment will be TWTC's responsibility. Where a dial-up facility is required, dial circuits will be installed in the AT&T data center by AT&T and the associated charges assessed to TWTC. Additionally, all message toll charges associated with the use of the dial circuit by TWTC will be the responsibility of TWTC. Associated equipment on the AT&T end, including a modem, will be negotiated on an individual case basis between the Parties. All equipment, including modems and software, that is required on TWTC end for the purpose of data transmission will be the responsibility of TWTC. 6.2.3 If TWTC utilizes FTP for data file transmission, purchase of the FTP software will be the responsibility of TWTC.

  • Mortgage Loan Characteristics The characteristics of the related Mortgage Loan Package are as set forth on the description of the pool characteristics for the applicable Mortgage Loan Package delivered pursuant to Section 11 on the related Closing Date in the form attached as Exhibit B to each related Assignment and Conveyance Agreement;

  • CHARACTERISTICS OF THE ACADEMY The characteristics of the Academy set down in Section 1(6) of the Academies Act 2010, are that:

  • Substance Abuse Testing The Parties agree that it is in the best interest of all concerned to promote a safe working environment. The Union has no objection to pre-employment substance abuse testing when required by the Employer and further, the Union has no objection to voluntary substance abuse testing to qualify for employment on projects when required by a project owner. The cost and scheduling of such testing shall be paid for and arranged by the Employer. The Union agrees to reimburse the Employer for any failed pre-access Alcohol and Drug test costs.

  • Client Classification 7.1. We shall not have an obligation to treat our clients in different classes depending on their knowledge and expertise.

  • SPECIALIZED SERVICE REQUIREMENTS In the event that the Participating Entity requires service or specialized performance requirements not addressed in this Contract (such as e- commerce specifications, specialized delivery requirements, or other specifications and requirements), the Participating Entity and the Supplier may enter into a separate, standalone agreement, apart from this Contract. Sourcewell, including its agents and employees, will not be made a party to a claim for breach of such agreement.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!