Common use of Developer’s Attachment Facilities Clause in Contracts

Developer’s Attachment Facilities. The Large Generating Facility is connected via three 34.5kV collector lines from the turbine fields to the Xxxx substation (“Xxxx Substation”), each line consists of a combination of underground and overhead 34.5 kV circuits. Underground circuits are solid dielectric 34.5 kV power cables direct buried in cable trenches 4 feet deep along newly created turbine access roads. Overhead circuits are jacketed Xxxxxxx type cable of compact design supported from wood structures and mounted on insulated brackets suspended from messenger wire. The overhead circuits are located along established county roads. Fiber optic cables are routed along power with certain physical separation. The Xxxx Substation is an outdoor air insulated low profile design, single bus configuration. The Xxxx Substation will include Developer’s Attachment Facilities, Transmission Owner’s Attachment Facilities, and, ultimately, some System Upgrade Facilities. The Transmission Owner’s Attachment Facilities and System Upgrade Facilities are described in Sections I.B. and II, respectively, of this Appendix A. The Developer’s Attachment Facilities in the Xxxx Substation consist of three 1200A circuit breakers for the collector lines and one 3000A main breaker for connecting the 34.5 kV collector bus to the 34.5/230kV step-up transformer. This breaker is SF6 type, rated 72 kV, 40 kA. The substation circuit breakers, disconnect switches, PTs, CTs, and surge arresters are interconnected together by a combination of strain buses and rigid buses mounted on porcelain insulators, supported on steel structures. The Xxxx Substation 34.5kV system includes circuit breaker current transformers and bus connected voltage transformers for metering and relaying. A 34.5 kV-120/208V station service transformer will supply power for the station service. All equipment, including fences, is grounded to a sub-grade grounding system designed to IEEE 80 requirements. The switchyard area shall be covered with a 6 inch layer of 0.75” crushed stone and will extend for a distance equal to 5 feet beyond the fence line. Grounding Transformer – Each collector line is connected with a grounding transformer at the substation end of the line to prevent line voltage rise between the time when the breaker is tripped and the turbines coast down. The Main Step-up Transformer is an outdoor mineral oil filled, forced air cooled, two winding 34.5/230 kV three phase transformer, rated at 75/92/120 MVA OA/FA/FAA. The transformer shall be connected grounded wye on the 34.5 kV side, and delta on the 230 kV side with a no-load tap changer. The transformer is equipped with surge arresters, current transformers, ANSI standard accessories and a continuous on-line gas monitor.

Appears in 5 contracts

Samples: Interconnection Agreement, Interconnection Agreement, Interconnection Agreement

AutoNDA by SimpleDocs

Developer’s Attachment Facilities. The Large Generating Facility is connected via three 34.5kV collector lines from the turbine fields to the Xxxx substation (“Xxxx Substation”), each line consists of a combination of underground and overhead 34.5 kV circuits. Underground circuits are solid dielectric 34.5 kV power cables direct buried in cable trenches 4 feet deep along newly created turbine access roads. Overhead circuits are jacketed Xxxxxxx type cable of compact design supported from wood structures and mounted on insulated brackets suspended from messenger wire. The overhead circuits are located along established county roads. Fiber optic cables are routed along power with certain physical separation. The Xxxx Substation is an outdoor air insulated low profile design, single bus configuration. The Xxxx Substation will include Developer’s Attachment Facilities, Transmission Owner’s Attachment Facilities, and, ultimately, some System Upgrade Facilities. The Transmission Owner’s Attachment Facilities and System Upgrade Facilities are described in Sections I.B. and II, respectively, of this Appendix A. The Developer’s Attachment Facilities in the Xxxx Substation consist of three 1200A circuit breakers for the collector lines and one 3000A main breaker for connecting the 34.5 kV collector bus to the 34.5/230kV step-up transformer. This breaker is SF6 type, rated 72 kV, 40 kA. The substation circuit breakers, disconnect switches, PTs, CTs, and surge arresters are interconnected together by a combination of strain buses and rigid buses mounted on porcelain insulators, supported on steel structures. The Xxxx Substation 34.5kV system includes circuit breaker current transformers and bus connected voltage transformers for metering and relaying. A 34.5 kV-120/208V station service transformer will supply power for the station service. All equipment, including fences, is grounded to a sub-grade grounding system designed to IEEE 80 requirements. The switchyard area shall be covered with a 6 inch layer of 0.75” crushed stone and will extend for a distance equal to 5 feet beyond the fence line. Grounding Transformer – Each collector line is connected with a grounding transformer at the substation end of the line to prevent line voltage rise between the time when the breaker is tripped and the turbines coast down. The Main Step-up Transformer is an outdoor mineral oil filled, forced air cooled, two winding 34.5/230 kV three phase transformer, rated at 75/92/120 MVA OA/FA/FAA. The transformer shall be connected grounded wye on the 34.5 kV side, and delta on the 230 kV side with a no-load tap changer. The transformer is equipped with surge arresters, current transformers, ANSI standard accessories and a continuous on-line gas monitor.

Appears in 4 contracts

Samples: Interconnection Agreement, Interconnection Agreement, Interconnection Agreement

AutoNDA by SimpleDocs

Developer’s Attachment Facilities. The Large Generating Facility is connected via three 34.5kV collector lines from the turbine fields to the Xxxx substation (“Xxxx Substation”), each line consists of a combination of underground and overhead 34.5 kV circuits. Underground circuits are solid dielectric 34.5 kV power cables direct buried in cable trenches 4 feet deep along newly created turbine access roads. Overhead circuits are jacketed Xxxxxxx type cable of compact design supported from wood structures and mounted on insulated brackets suspended from messenger wire. The overhead circuits are located along established county roads. Fiber optic cables are routed along power with certain physical separation. The Xxxx Marble River Collection Substation is an outdoor air insulated low profile design, single bus configuration. The Xxxx Substation will include Developer’s Attachment FacilitiesIt consists of one 230kV, Transmission Owner’s Attachment Facilities2000A three-phase switch, andeight 34.5kV, ultimately1200A, some System Upgrade Facilities. The Transmission Owner’s Attachment Facilities and System Upgrade Facilities are described in Sections I.B. and II, respectively, of this Appendix A. The Developer’s Attachment Facilities in the Xxxx Substation consist of three 1200A 40kA interrupting vacuum circuit breakers - six for the collector lines and collection circuits, two for the mechanically switched capacitor banks. There is also one 3000A 4000A main breaker for connecting the 34.5 kV 34.5kV collector bus to the 34.5/230kV step-up transformer. This particular breaker is an SF6 type, rated 72 kV, 40 kA. 121kV and 550kV BIL and 40kA interrupting capability. The voltage and BIL ratings are higher than typical 34.5kV installations due to required current carrying capacity. The substation circuit breakers, disconnect switches, PTs, CTs, and surge arresters are interconnected together by a combination of strain buses and rigid buses mounted on porcelain insulators, supported on steel structures. There are also two blocks of 34.5kV 20 MVAR shunt capacitor banks, switched at 10 MVAR intervals, with capacitor switchers rated 600A, 40 kA interrupting, connected to the collector bus. The Xxxx Marble River Collection Substation 34.5kV system includes circuit breaker current transformers and bus connected voltage transformers transformer for metering and relaying. A 34.5 kV-120/208V dedicated 167 kVA 34.5kV/120-240V station service transformer will supply power for the station serviceservice to the Xxxxxxx 230kV Switchyard. A separate 34.5 kV/120-240 VAC 75 kVA transformer will supply the station service to the Marble River substation. All equipment, including fences, is grounded to a sub-grade grounding system designed to IEEE 80 requirements. The switchyard area substation area, including three feet beyond the fence, shall be covered with six inches of stone. The stone shall consist of clean, angular fragments of rock, free from soft disintegrated pieces or objectionable matter. The Marble River Collection Substation is being built adjacent to the POI substation. The connection between the substation is a 6 inch layer of 0.75” crushed stone and will extend for a distance equal to 5 feet beyond the fence line. Grounding Transformer – Each collector line is connected short 230 KV bus section with a grounding transformer at the substation end of the line final connection with bus jumpers to prevent line voltage rise between the time when the breaker is tripped and the turbines coast down. The Main Step-up Transformer is an outdoor mineral oil filled, forced air cooled, two winding 34.5/230 kV three phase transformer, rated at 75/92/120 MVA OA/FA/FAA. The transformer shall be connected grounded wye on the 34.5 kV side, and delta on the Marble River’s 230 kV side with a no-load tap changer. The transformer is equipped with surge arresters, current transformers, ANSI standard accessories and a continuous on-line gas monitordisconnect switches.

Appears in 1 contract

Samples: Interconnection Agreement