Diesel Engine and Auxiliaries Sample Clauses

Diesel Engine and Auxiliaries. (a) Diesel Engine The diesel engine shall be capable of operating on No. 2 diesel fuel and shall not require premium diesel fuel for satisfactory performance. The engine shall be rated to produce required output at elevation 288.00 m MSL, at 45oC ambient temperature and 99 percent relative humidity. The diesel engine may be either normally aspirated or supercharged. The engine and generator shall be supplied complete with a common bedplate suitable for mounting on a concrete foundation. Adjustable steel spring type vibration isolators with sound pads shall provide for mounting between the unit base and concrete foundation. A suitable oil drip pan shall be provided under the full length of the diesel and generator to catch oil leakage.
AutoNDA by SimpleDocs

Related to Diesel Engine and Auxiliaries

  • INTERNET PLANNING, ENGINEERING AND OPERATIONS ‌ Job Title: Internet/Web Engineer Job#: 2620 General Characteristics Integrally involved in the development and support of all Internet/Intranet/Extranet sites and supporting systems. Works closely with other IT groups and customers to define the system design and user interface based on customer needs and objectives. Participates in all phases of the development and implementation process, and may act as a project manager on special projects. Ensures the integration of the Web servers and all other supporting systems. Responsible for system tuning, optimization of information/data processing, maintenance and support of the production environment.

  • Reactive Power 1.8.1 The Interconnection Customer shall design its Small Generating Facility to maintain a composite power delivery at continuous rated power output at the Point of Interconnection at a power factor within the range established by the Connecting Transmission Owner on a comparable basis, until NYISO has established different requirements that apply to all similarly situated generators in the New York Control Area on a comparable basis.

  • Cloud Computing State Risk and Authorization Management Program In accordance with Senate Bill 475, Acts 2021, 87th Leg., R.S., pursuant to Texas Government Code, Section 2054.0593, Contractor acknowledges and agrees that, if providing cloud computing services for System Agency, Contractor must comply with the requirements of the state risk and authorization management program and that System Agency may not enter or renew a contract with Contractor to purchase cloud computing services for the agency that are subject to the state risk and authorization management program unless Contractor demonstrates compliance with program requirements. If providing cloud computing services for System Agency that are subject to the state risk and authorization management program, Contractor certifies it will maintain program compliance and certification throughout the term of the Contract.

  • Police Powers The Grantee agrees to comply with the terms of any lawfully adopted generally applicable local ordinance necessary to the safety, health, and welfare of the public, to the extent that the provisions of the ordinance do not have the effect of limiting the benefits or expanding the obligations of the Grantee that are granted by this Franchise. This Franchise is a contract and except as to those changes which are the result of the Grantor’s lawful exercise of its general police power, the Grantor may not take any unilateral action which materially changes the mutual promises in this contract.

  • Skills and Abilities (i) Ability to communicate effectively both verbally and in writing.

  • Contractor’s Power and Authority The Contractor warrants that it has the full power and authority to grant the rights herein granted and will hold the County hereunder harmless from and against any loss, cost, liability and expense, including reasonable attorney fees, arising out of any breach of this warranty. Further, the Contractor avers that it will not enter into any arrangement with any third party which might abridge any rights of the County under this Contract.

  • Technical Standards Applicable to a Wind Generating Plant i. Low Voltage Ride-Through (LVRT) Capability A wind generating plant shall be able to remain online during voltage disturbances up to the time periods and associated voltage levels set forth in the standard below. The LVRT standard provides for a transition period standard and a post-transition period standard.

  • Reactive Power and Primary Frequency Response 9.6.1 Power Factor Design Criteria

  • Knowledge, Skills and Abilities Shall be knowledgeable in replacement/adjustment of closures, locks, hinges and handles on commercial steel door systems. - Repairs, installs, and maintains commercial plumbing services such as closet and urinal diaphragms and flush valves. - Have obtained previous certification in using boom and scissor lifts. - Have obtained previous certification in using forklift. MINIMUM JOB QUALIFICATIONS: - One-year certificate from an appropriate technical/military school or completion of trade apprenticeship; or three years verifiable experience in a related field. - Ability to read, write and speak English, interpret documents such as safety rules, operating and maintenance instructions, blue prints, wiring diagrams and equipment manuals. Ability to write routine reports and correspondence. Ability to communicate effectively with building occupants and employees of OCCC. - Ability to add, subtract, multiply and divide. - Shall possess a valid Florida Driver’s license (or State issued ID) for the duration of employment in this position. - Willing to work in a team atmosphere and be willing to work alongside OCCC employees.

  • Erosion and Sediment Control The Contractor shall install and maintain erosion and sediment control devices to prevent adjacent streets, storm drains and property from accumulations of soil, sediment, or dust which result from his work. Devices installed to control sediment and prevent erosion shall comply with the requirements of the Georgia Tech Project Superintendent. The Contractor is responsible for monitoring downstream conditions throughout the construction period and clearing any debris, sediment, and dust caused by the progress of the Work. The Contractor shall inspect, maintain, and clear erosion and sediment control devices at least weekly unless otherwise directed by the Georgia Institute of Technology Construction Manager. At the conclusion of the Work, the Contractor shall remove all installed devices and restoring the site to the satisfaction of the Georgia Tech Construction Manager.