Distribution System Operator Sample Clauses

Distribution System Operator. 6. Jaotussüsteemi haldur When signing the Special Provisions, the Parties acknowledge and agree that they have become familiar with and discussed all the provisions of the Contract, understand them and agree therewith, as well as undertake to comply therewith from the day of signing of the Contract. Erisätete allkirjastamisel tunnistavad pooled ja nõustuvad, et nad on tutvunud kõigi lepingu sätetega ja arutanud neid, mõistavad xxxx xx nõustuvad nendega, samuti kohustuvad neid täitma alates lepingu allkirjastamise päevast. SELLER / MÜÜJA BUYER / OSTJA *signature/ allkiri *signature / allkiri DOCUMENT IS SIGNED WITH SECURE ELECTRONIC SIGNATURE AND CONTAINS TIMESTAMP DOKUMENT ON ALLKIRJASTATUD TURVALISE ELEKTROONILISE ALLKIRJAGA JA SISALDAB AJATEMPLIT Annex 1 to Contract No. / 1. xxxx xxxxxxxxx nr Date / Kuupäev: Netw ork opera tor Ident. number of Delivery Point/ Metering point/ Object Address of Delivery Point/ Metering Point/ Object address Natural gas pressure [bar(g)] Purpose of natural gas consumptio n Biggest allowed natural gas flow Qmax [m3 and/or kWh] Smallest allowed natural gas flow Qmin [m3 and/or kWh] Consumption Capacity [m3 and/or kWh/Day and Year] Estimated natural gas quantity duaring Contract [Tuh.m3] Võrg uoper aator Tarnepunkti / mõõtepunkti / objekti tuvastusnum ber Aadress Tarnepunkt / mõõtepunkt / Objekti aadress Maagaasi rõhk [bar(g)] Maagaasi tarbimise eesmärk Suurim lubatud maagaasi vool Qmax [m3 ja/või kWh] Väikseim lubatud maagaasi vool Qmin [m3 ja/või kWh] Tarbimisvõimsus [m3 ja/või kWh/xxxx xx aasta] Hinnanguli ne maagaasi koguse kahekordis tamine [Tuh.m3]
AutoNDA by SimpleDocs
Distribution System Operator. In order to correctly perform power quality management and energy load balancing the DSO has the following security goals: DSO_SG01 ensure data integrity and authenticity of measurement data (i.e. Measurement Data, Sensor Data, kWh Data) and monitoring data (e.g. Current Status Data) during transfer and storage. DSO_SG02 ensure the availability of measurement and monitoring data. DSO_SG03 ensure data integrity and authenticity of control messages send from the DSO to the DER (e.g. Set Point) and to households (e.g. Change Consumption/Generation Command) to change production or consumption. In order to correctly perform market facilitation in accordance with the SLA with the data hub and applicable legal requirements and regulations (o.a. UC1, UC3) the DSO has the following security goals2: DSO_SG05 ensure data integrity and authenticity of measurement data during transfer and storage. DSO_SG06 ensure availability of measurement data during transfer and storage. DSO_SG07 ensure data integrity and authenticity of switch data during transfer and storage. DSO_SG08 ensure data integrity and authenticity of monitoring data during transfer and storage. For the local load balancing renewable energy (UC4) & local automatic reconfiguration of the power grid (UC5), it is important that the topology model (i.e. Dynamic Network Topology Data) is correct at substation level. To this end, the DSO has the following security goal: DSO_SG09 ensure data integrity and authenticity of monitoring data (e.g. Fault data, Sensor data) and network topology data (e.g. Dynamic Network Topology Data) during transfer and storage.

Related to Distribution System Operator

  • California Independent System Operator Corporation a California nonprofit public benefit corporation having a principal executive office located at such place in the State of California as the CAISO Governing Board may from time to time designate (the “CAISO”).

Time is Money Join Law Insider Premium to draft better contracts faster.