Access to Site 3.05.1 Contractor may enter and leave the premises at all reasonable times without charge. Contractor and its employees may use the common areas and roadways of the premises where it is to perform the services together with all facilities, equipment, improvements, and services provided in connection with the premises for common use. This excludes parking for Contractor’s personnel. Contractor shall repair any damage caused by it or its employees as a result of its use of the common areas.
Use of Interconnection Facilities by Third Parties 6551 Error! Hyperlink reference not valid.9.9.1 Purpose of Interconnection Facilities. 6551
Geographic Area and Sector Specific Allowances, Conditions and Exceptions The following allowances and conditions shall apply where relevant. Where the Employer does work which falls under the following headings, the Employer agrees to pay and observe the relevant respective conditions and/or exceptions set out below in each case.
Trunk Group Architecture and Traffic Routing 5.2.1 The Parties shall jointly establish Access Toll Connecting Trunks between CLEC and CBT by which they will jointly provide Tandem-transported Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic from and to CLEC's Customers. 5.2.2 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access and non-translated Toll Free traffic (e.g., 800/888) to allow CLEC’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier that is connected to the CBT access Tandem. 5.2.3 The Access Toll Connecting Trunks shall be one-way or two-way trunks, as mutually agreed, connecting an End Office Switch that CLEC utilizes to provide Telephone Exchange Service and Switched Exchange Access Service in the given LATA to an access Tandem Switch CBT utilizes to provide Exchange Access in the LATA.
TLD Nameservers ICANN will use commercially reasonable efforts to ensure that any changes to the TLD nameserver designations submitted to ICANN by Registry Operator (in a format and with required technical elements specified by ICANN at xxxx://xxx.xxxx.xxx/domains/root/ will be implemented by ICANN within seven (7) calendar days or as promptly as feasible following technical verifications.
Access Toll Connecting Trunk Group Architecture 9.2.1 If CSTC chooses to subtend a Verizon access Tandem, CSTC’s NPA/NXX must be assigned by CSTC to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG. 9.2.2 CSTC shall establish Access Toll Connecting Trunks pursuant to applicable access Tariffs by which it will provide Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic to and from CSTC’s Customers. 9.2.3 The Access Toll Connecting Trunks shall be two-way trunks. Such trunks shall connect the End Office CSTC utilizes to provide Telephone Exchange Service and Switched Exchange Access to its Customers in a given LATA to the access Tandem(s) Verizon utilizes to provide Exchange Access in such LATA. 9.2.4 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access to allow CSTC’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier which is connected to a Verizon access Tandem.
Permitted and Required Uses/Disclosures of PHI 3.1 Except as limited in this Agreement, Business Associate may use or disclose PHI to perform Services, as specified in the underlying grant or contract with Covered Entity. The uses and disclosures of Business Associate are limited to the minimum necessary, to complete the tasks or to provide the services associated with the terms of the underlying agreement. Business Associate shall not use or disclose PHI in any manner that would constitute a violation of the Privacy Rule if used or disclosed by Covered Entity in that manner. Business Associate may not use or disclose PHI other than as permitted or required by this Agreement or as Required by Law. 3.2 Business Associate may make PHI available to its employees who need access to perform Services provided that Business Associate makes such employees aware of the use and disclosure restrictions in this Agreement and binds them to comply with such restrictions. Business Associate may only disclose PHI for the purposes authorized by this Agreement: (a) to its agents and Subcontractors in accordance with Sections 9 and 17 or, (b) as otherwise permitted by Section 3. 3.3 Business Associate shall be directly liable under HIPAA for impermissible uses and disclosures of the PHI it handles on behalf of Covered Entity, and for impermissible uses and disclosures, by Business Associate’s Subcontractor(s), of the PHI that Business Associate handles on behalf of Covered Entity and that it passes on to Subcontractors.
Know-How Necessary for the Business The Intellectual Property Rights are all those necessary for the operation of the Company’s businesses as it is currently conducted or as represented, in writing, to the Purchasers to be conducted. The Company is the owner of all right, title, and interest in and to each of the Intellectual Property Rights, free and clear of all liens, security interests, charges, encumbrances, equities, and other adverse claims, and has the right to use all of the Intellectual Property Rights. To the Company’s knowledge, no employee of the Company has entered into any contract that restricts or limits in any way the scope or type of work in which the employee may be engaged or requires the employee to transfer, assign, or disclose information concerning his work to anyone other than of the Company.
Access to NID 2.7.3.1 NewPhone may access the customer’s premises wiring by any of the following means and NewPhone shall not disturb the existing form of electrical protection and shall maintain the physical integrity of the NID: 2.7.3.1.1 BellSouth shall allow NewPhone to connect its Loops directly to BellSouth’s multi-line residential NID enclosures that have additional space and are not used by BellSouth or any other telecommunications carriers to provide service to the premises; 2.7.3.1.2 Where an adequate length of the customer’s premises wiring is present and environmental conditions permit, either Party may remove the customer premises wiring from the other Party’s NID and connect such wiring to that Party’s own NID; 2.7.3.1.3 Either Party may enter the subscriber access chamber or dual chamber NID enclosures for the purpose of extending a cross-connect or spliced jumper wire from the customer premises wiring through a suitable “punch-out” hole of such NID enclosures; or 2.7.3.1.4 NewPhone may request BellSouth to make other rearrangements to the customer premises wiring terminations or terminal enclosure on a time and materials cost basis. 2.7.3.2 In no case shall either Party remove or disconnect the other Party’s loop facilities from either Party’s NIDs, enclosures, or protectors unless the applicable Commission has expressly permitted the same and the disconnecting Party provides prior notice to the other Party. In such cases, it shall be the responsibility of the Party disconnecting loop facilities to leave undisturbed the existing form of electrical protection and to maintain the physical integrity of the NID. It will be NewPhone’s responsibility to ensure there is no safety hazard, and NewPhone will hold BellSouth harmless for any liability associated with the removal of the BellSouth Loop from the BellSouth NID. Furthermore, it shall be the responsibility of the disconnecting Party, once the other Party’s loop has been disconnected from the NID, to reconnect the disconnected loop to a nationally recognized testing laboratory listed station protector, which has been grounded as per Article 800 of the National Electrical Code. If no spare station protector exists in the NID, the disconnected loop must be appropriately cleared, capped and stored. 2.7.3.3 NewPhone shall not remove or disconnect ground wires from BellSouth’s NIDs, enclosures, or protectors. 2.7.3.4 NewPhone shall not remove or disconnect NID modules, protectors, or terminals from BellSouth’s NID enclosures. 2.7.3.5 Due to the wide variety of NID enclosures and outside plant environments, BellSouth will work with NewPhone to develop specific procedures to establish the most effective means of implementing this section if the procedures set forth herein do not apply to the NID in question.
Limitation on Lines of Business Enter into any business, either directly or through any Subsidiary, except for those businesses in which the Borrower and its Subsidiaries are engaged on the date of this Agreement or that are reasonably related thereto.