Election not to Construct Facilities to Connect a Water Source to the System Sample Clauses

Election not to Construct Facilities to Connect a Water Source to the System. If Midstream Co determines, in its discretion, that the construction of facilities to connect a Water Source to the System to deliver Services to Original Producer would be uneconomical, then upon Midstream Co’s delivery of a System Plan (marked as “Final”) indicating that a requested expansion would be uneconomical pursuant to Section 13.2(f): (i) No more than 30 Days after delivery of the System Plan pursuant to Section 13.2(d) above, Midstream Co shall provide Original Producer Midstream Co’s proposed terms and conditions under which it would construct facilities to connect a Water Source to the System under the terms of this Agreement, including estimated construction costs. Original Producer shall have 30 Days to accept or reject Midstream Co’s terms and conditions. If Original Producer accepts Midstream Co’s proposed terms and conditions, then Midstream Co shall, within 30 Days thereof, provide Original Producer with an updated System Plan detailing the construction of facilities to connect a Water Source to the System. If Original Producer does not respond to Midstream Co’s terms and conditions within such - 43 - 30-Day period, it shall be deemed to have rejected Midstream Co’s proposed terms and conditions (ii) If Original Producer rejects Midstream Co’s terms and conditions under clause (A) above, then Original Producer may, at its sole cost and expense, simultaneously elect in writing to cause Midstream Co to construct facilities to connect a Water Source to the System, such facilities will become part of the Individual System and the property of Midstream Co. The Parties shall meet and cooperate in good faith to ensure any facilities constructed under this clause (ii) have the capacity to handle the estimated Fresh Water that is subject to the Fresh Water Dedication in the Development Report and comply with customary engineering, construction and operating specifications in the industry. Within 30 Days of Original Producer’s election hereunder, Midstream Co shall provide Original Producer with an updated System Plan detailing the construction of facilities to connect a Water Source to the System, any costs and expenses shall be included on the monthly invoice and paid in accordance with Section 10.1 and Section 10.2 and such facilities shall otherwise be governed by Section 3.1(d). Beginning on the first Day Midstream Co receives Fresh Water Tendered by Original Producer for delivery to any facility constructed in accordance with this clause (ii...
AutoNDA by SimpleDocs

Related to Election not to Construct Facilities to Connect a Water Source to the System

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

  • Modification of the Small Generating Facility The Interconnection Customer must receive written authorization from the NYISO and Connecting Transmission Owner before making any change to the Small Generating Facility that may have a material impact on the safety or reliability of the New York State Transmission System or the Distribution System. Such authorization shall not be unreasonably withheld. Modifications shall be done in accordance with Good Utility Practice. If the Interconnection Customer makes such modification without the prior written authorization of the NYISO and Connecting Transmission Owner, the Connecting Transmission Owner shall have the right to temporarily disconnect the Small Generating Facility. If disconnected, the Small Generating Facility will not be reconnected until the unauthorized modifications are authorized or removed.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CSTC chooses to subtend a Verizon access Tandem, CSTC’s NPA/NXX must be assigned by CSTC to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG. 9.2.2 CSTC shall establish Access Toll Connecting Trunks pursuant to applicable access Tariffs by which it will provide Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic to and from CSTC’s Customers. 9.2.3 The Access Toll Connecting Trunks shall be two-way trunks. Such trunks shall connect the End Office CSTC utilizes to provide Telephone Exchange Service and Switched Exchange Access to its Customers in a given LATA to the access Tandem(s) Verizon utilizes to provide Exchange Access in such LATA. 9.2.4 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access to allow CSTC’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier which is connected to a Verizon access Tandem.

  • Participating TO’s Interconnection Facilities The Participating TO shall design, procure, construct, install, own and/or control the Participating TO’s Interconnection Facilities described in Appendix A at the sole expense of the Interconnection Customer. Unless the Participating TO elects to fund the capital for the Participating TO’s Interconnection Facilities, they shall be solely funded by the Interconnection Customer.

  • Selection of Subcontractors, Procurement of Materials and Leasing of Equipment The contractor shall not discriminate on the grounds of race, color, religion, sex, national origin, age or disability in the selection and retention of subcontractors, including procurement of materials and leases of equipment. The contractor shall take all necessary and reasonable steps to ensure nondiscrimination in the administration of this contract. a. The contractor shall notify all potential subcontractors and suppliers and lessors of their EEO obligations under this contract. b. The contractor will use good faith efforts to ensure subcontractor compliance with their EEO obligations.

  • Access to the Services ID’s for access to Vendor Core Research and Analyst Inquiry may not be shared. Access to the Services is restricted to the number of named individuals (each a “Licensed User”) as identified in the Customer Purchase Order.

  • Use of Interconnection Facilities by Third Parties 6551 Error! Hyperlink reference not valid.9.9.1 Purpose of Interconnection Facilities. 6551

  • Cost Responsibility for Interconnection Facilities and Distribution Upgrades 4.1 Interconnection Facilities 4.2 Distribution Upgrades

  • Access to Work District representatives shall at all times have access to the Work, wherever it is, in preparation or in progress. Contractor shall provide safe and proper facilities for such access.

  • Access to Services Subject to and in accordance with the terms of this Agreement, including any Schedules, Company grants You a non-exclusive, non-sublicensable, nontransferable, non-assignable, revocable license for the term of this Agreement to access and use the Services. Services may only be used by Your Users for internal business purposes only. You agree to comply with the terms and conditions of this Agreement, including any Schedules, and with all applicable Company procedures and policies that further define use of the Services. You acknowledge and agree that the actions of any of Your Users with respect to the Services will be deemed to be actions by You and that any breach by any of Your Users of the terms of this Agreement, including any Schedule, will be deemed to be a breach by You.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!