Enclosure System Sample Clauses

Enclosure System. Cover the containment floor or ground beneath the structure being prepared with air and dust impenetrable materials such as solid panels of plywood or flexible materials such as tarpaulins, if it serves as the base of the containment. Maintain the materials throughout the project to avoid losing debris through rips, tears, or breaks in the coverings. Tarpaulins are not required on the decking/containment platform unless the platform is not preventing the release of spent abrasive, dust, and debris. If spent abrasive, dust, or debris is observed falling through gaps in the decking, seal the decking so that emissions are controlled or install tarpaulins over the decking. Verify that the platform and its components are designed and constructed to support at least 4 times its maximum intended load without failure with wire cables capable of supporting at least 6 times their intended load without failure, if a suspended or elevated platform is constructed to serve as the base of the containment. Follow applicable OSHA regulations regarding scaffolding. Design each SSPC Guide 6 Class 1A or 2A containment system to meet minimum air flow velocities of 60 feet per minute down-draft or 100 feet per minute cross-draft. Remove debris from the containment materials and equipment before relocation to another point along the structure. Clean to the extent that debris or dust are not dislodged by winds or physical contact during handling and transportation.
AutoNDA by SimpleDocs

Related to Enclosure System

  • Drainage Systems (1) Clear culvert inlets, outlets, and sediment catching basins.

  • Unbundled Sub-Loop Concentration System (USLC 2.9.1 Where facilities permit and where necessary to comply with an effective Commission order, BellSouth will provide <<customer_name>> with the ability to concentrate its sub-loops onto multiple DS1s back to the BellSouth Central Office. The DS1s will then be terminated into <<customer_name>>’s collocation space. TR-008 and TR303 interface standards are available.

  • Irrigation Systems The Project Area either has no irrigation system or a low-volume drip irrigation system. If a watering system is used, it is a drip irrigation system equipped with a filter, pressure regulator and emitters rated at twenty (20) gallons per hour (gph) or less. The system is maintained free of leaks and malfunctions. No spray irrigation is applied to the Project Area, including spray from irrigation systems adjacent to the Project Area.

  • Energy Resource Interconnection Service (ER Interconnection Service).

  • Removable media devices All electronic files that contain County PHI or PI data must be encrypted when stored on any removable media or portable device (i.e. USB thumb drives, floppies, CD/DVD, smartphones, backup tapes etc.). Encryption must be a FIPS 140-2 certified algorithm which is 128bit or higher, such as AES.

  • CONSTRUCTION/PUBLIC WORKS CONTRACTS In compliance with Article 8, Section 220 of the New York State Labor Law:

  • TRANSPORTATION AND TRAVEL TIME 12.01 The Employer will provide transportation to and from jobs from the Employer’s shop. If an employee’s car is used for such transportation, the owner shall be paid fifty cents (50¢) per kilometre for such use.

  • Fire Safety 9.5.1 Residents found in violation of the following fire safety stipulations not only put themselves at risk but also jeopardizes the safety of the entire community.

  • Fueling delivering or dispensing fuel, defueling and refueling, or any other transfer of fuel on Airport property.

  • Utilities and Appliances (1) The owner must provide all utilities needed to comply with the HQS.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!