Fill Importation Requirements. If the Developer intends to import or export fill from, onto, or off of the subject site, the Developer shall prepare and implement a Soil Testing, Site/Soil Management, and Reporting Protocol to address the following to the satisfaction of the Township: i) Report to the Township test results of soils, prior to the material being received by the Developer at the frequency recommended by the Developers’ environmental consultant and not less than once per week and /or one test per four hundred (400) tonnes of material received; ii) Report to the Township that the actual test results of the soils being received by the Developer will be provided to the Township and in addition the Developer giving a report that states that the material is in accordance to Provincial standards, and that the material is suitable for the intended use and poses no risk to the existing natural environment and local ground water. This report is to be submitted to the Township for comment prior to the material being placed on the Lands; iii) Inspection and management protocols of the operation to ensure that only tested material is being received; and iv) Incorporate a reference to the MECP documents dated January, 2014, titled “Management of Excess Soil – A Guide for Best Management Practices” and dated April 15, 2011, titled “Soil, Ground Water and Sediment Standards for Use Under Part XV.1 of the Environmental Protection Act”. v) Should a Site Alteration Agreement be provided for the Lands, such an agreement supersedes this Section 12.9 to the extent that they are inconsistent. vi) Inspection and management in accordance with O. Reg. 406/19, titled “On-Site and Excess Soil Management”.
AutoNDA by SimpleDocs
Fill Importation Requirements. If the Developer intends to import fill from off the subject site for use on the site, the Developer shall prepare and implement a Soil Testing, Site/Soil Management, and Reporting Protocol to the satisfaction of the Township.

Related to Fill Importation Requirements

  • Installation requirements We (if we install the System) or our contractor (if we procure a contractor to install the System) must:

  • GRADUATION REQUIREMENTS I understand that in order to graduate from the program and to receive a certificate of completion, diploma or degree I must successfully complete the required number of scheduled clock hours as specified in the catalog and on the Enrollment Agreement, pass all written and practical examinations with a minimum score of 80%, and complete all required clinical hours and satisfy all financial obligations to the College.

  • Application Requirements This application shall contain, as a minimum, a sketch showing the location of proposed facilities; a description, sketch, manufacturer’s brochure, etc. of the proposed facilities; and a description of the operation proposed. (11-28-90) 101. -- 199. (RESERVED)‌ 200. OPERATIONAL AGREEMENT.‌‌

  • Construction Requirements (a) All Life and Safety and applicable Building Codes will be strictly enforced (i.e., tempered glass, fire dampers, exit signs, smoke detectors, alarms, etc.). Prior coordination with the Building Manager is required. (b) Electric panel schedules must be brought up to date identifying all new circuits added. (c) All electrical outlets and lighting circuits are to be properly identified. Outlets will be labeled on back side of each cover plate. (d) All electrical and phone closets being used must have panels replaced and doors shut at the end of each day’s work. Any electrical closet that is opened with the panel exposed must have a work person present. (e) All electricians, telephone personnel, etc. will, upon completion of their respective projects, pick up and discard their trash leaving the telephone and electrical rooms clean. If this is not complied with, a clean-up will be conducted by the building janitors and the general contractor will be back-charged for this service. (f) Welding or burning with an open flame will not be done without prior approval of the Building Manager. Fire extinguishers must be on hand at all times. (g) All “anchoring” of walls or supports to the concrete are not to be done during normal working hours (7:30 AM—6:00 PM, Monday through Friday). This work must be scheduled before or after these hours during the week or on the weekend. (h) All core drilling is not to be done during normal working hours (7:30 AM—6:00 PM, Monday through Friday). This work must be scheduled before or after these hours during the week or on the weekend. (i) All HVAC work must be inspected by the Building Engineer. The following procedures will be followed by the general contractor: i) A preliminary inspection of the HVAC work in progress will be scheduled through the Building Office prior to the reinstallation of the ceiling grid. ii) A second inspection of the HVAC operation will also be scheduled through the Building Office and will take place with the attendance of the HVAC contractor’s Air Balance Engineer. This inspection will take place when the suite in question is ready to be air-balanced. [***] = CONFIDENTIAL INFORMATION HAS BEEN OMITTED AND FILED SEPARATELY WITH THE SECURITIES AND EXCHANGE COMMISSION. CONFIDENTIAL TREATMENT HAS BEEN REQUESTED WITH RESPECT TO THIS OMITTED INFORMATION. iii) The Building Engineer will inspect the construction on a periodic basis as well. (j) All existing thermostats, ceiling tiles, lighting fixtures and air conditioning grilles shall be saved and turned over to the Building Engineer.

  • Encryption Requirements DST will not locally store Fund Data on any laptops or mobile devices (e.g., Blackberries, PDAs) managed by DST.

  • Notification Requirements 1. If the Family Leave is foreseeable, the employee must provide the agency/department with thirty (30) calendar days notice of his or her intent to take Family Leave. 2. If the event necessitating the Family Leave becomes known to the employee less than thirty (30) calendar days prior to the employee's need for Family Leave, the employee must provide as much notice as possible. In no case shall the employee provide notice later than five (5) calendar days after he or she learns of the need for Family Leave. 3. For foreseeable leave due to a qualifying exigency, an employee must provide notice of the need for leave as soon as practicable, regardless of how far in advance such leave is foreseeable. 4. When the Family Leave is for the purpose of the scheduled medical treatment or planned medical care of a child, parent, spouse or registered domestic partner, the employee shall, to the extent practicable, schedule treatment and/or care in a way that minimizes disruption to agency/department operations.

  • Qualification Requirements In addition to ITB 13.1, ITB 13.2, and ITB 13.3 (b), the potential bidder must also fulfill the following:- a) The Bidder must be a Manufacturer or an Authorized Dealer or service provider for sales & service continuously from last one- year.

  • Food Service Waste Reduction Requirements Contractor shall comply with the Food Service Waste Reduction Ordinance, as set forth in San Francisco Environment Code Chapter 16, including but not limited to the remedies for noncompliance provided therein.

  • Distribution Requirements Arts 3 A course in history, philosophy, theory, or practice of the creative and interpretive arts.

  • Documentation Requirements ODM shall pay the MCP after it receives sufficient documentation, as determined by ODM, detailing the MCP’s Ohio Medicaid-specific liability for the Annual Fee. The MCP shall provide documentation that includes the following: 1. Total premiums reported on IRS Form 8963;

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!