Annual Operating Plan Purchaser may be required to submit a written annual operating plan, as specified by, and at the request of the Forest Officer.
Operating Plan To Agent and Lenders, as soon as available, but not later than thirty (30) days after the end of each Fiscal Year, an annual combined operating plan (the "Operating Plan") for Parent and its Subsidiaries, approved by the Board of Directors of Parent, for the following Fiscal Year, which (i) includes a statement of all of the material assumptions on which such plan is based, (ii) includes projected monthly income statement, balance sheets and source and use of funds for the following year and (iii) Borrowing Availability projections, all prepared on the same basis and in similar detail as that on which operating results are reported (and in the case of cash flow projections, representing management's good faith estimates of future financial performance based on historical performance), and including plans for personnel, Capital Expenditures and facilities.
Minimum Debt Service Coverage Ratio As of the first day of each fiscal quarter for the immediately preceding consecutive four fiscal quarters, the ratio of Combined EBITDA to Combined Debt Service shall not be less than 1.50 to 1.00.
Projected Operating Budget Furnish Lenders, no later than thirty (30) days after the beginning of Borrower's fiscal years commencing with fiscal year 2000, a month by month projected operating budget and cash flow of Borrower for such fiscal year (including an income statement for each month and a balance sheet as at the end of the last month in each fiscal quarter), such projections to be accompanied by a certificate signed by the President or Chief Financial Officer of Borrower to the effect that such projections have been prepared on the basis of financial planning practice consistent with past budgets and financial statements and that such officer has no reason to question the reasonableness of any material assumptions on which such projections were prepared.
Commercial Operation Date Testing and Modifications Prior to the Commercial Operation Date, the Connecting Transmission Owner shall test the Connecting Transmission Owner’s Attachment Facilities (including required control technologies and protection systems) and System Upgrade Facilities and System Deliverability Upgrades and Developer shall test the Large Generating Facility and the Developer’s Attachment Facilities to ensure their safe and reliable operation. Similar testing may be required after initial operation. Developer and Connecting Transmission Owner shall each make any modifications to its facilities that are found to be necessary as a result of such testing. Developer shall bear the cost of all such testing and modifications. Developer shall generate test energy at the Large Generating Facility only if it has arranged for the injection of such test energy in accordance with NYISO procedures.
Annual Operating Budget and Financial Projections Within sixty (60) days after the end of each fiscal year of Borrower Representative (and promptly and within five (5) days of any material modification thereto), an annual operating budgets, on a consolidating basis (including income statements, balance sheets and cash flow statements, by month) for the upcoming fiscal year of Borrower Representative, as approved by Borrower Representative’s Board, together with any related business forecasts used in the preparation of such annual financial projections.
Debt Service Coverage The Company will not, and will not permit any Subsidiary to, incur any Debt (including, without limitation, Acquired Debt) other than Intercompany Debt, if the ratio of Consolidated Income Available for Debt Service to the Annual Debt Service Charge for the period consisting of the four consecutive fiscal quarters most recently ended prior to the date on which such additional Debt is to be incurred is less than 1.5 to 1.0, on a pro forma basis after giving effect to the incurrence of such Debt and the application of the proceeds therefrom, and calculated on the assumption that (i) such Debt and any other Debt (including, without limitation, Acquired Debt) incurred by the Company or any of its Subsidiaries since the first day of such four-quarter period and the application of the proceeds therefrom (including to refinance other Debt since the first day of such four-quarter period) had occurred on the first day of such period, (ii) the repayment or retirement of any other Debt of the Company or any of its Subsidiaries since the first day of such four-quarter period had occurred on the first day of such period (except that, in making such computation, the amount of Debt under any revolving credit facility, line of credit or similar facility shall be computed based upon the average daily balance of such Debt during such period), and (iii) in the case of any acquisition or disposition by the Company or any Subsidiary of any asset or group of assets since the first day of such four-quarter period, including, without limitation, by merger, stock purchase or sale, or asset purchase or sale or otherwise, such acquisition or disposition had occurred on the first day of such period with the appropriate adjustments with respect to such acquisition or disposition being included in such pro forma calculation. If the Debt giving rise to the need to make the foregoing calculation or any other Debt incurred after the first day of the relevant four-quarter period bears interest at a floating rate then, for purposes of calculating the Annual Debt Service Charge, the interest rate on such Debt shall be computed on a pro forma basis as if the average interest rate which would have been in effect during the entire such four-quarter period had been the applicable rate for the entire such period.
Operating Schedule Purchaser shall, be- fore commencing operations, provide in writing an annual Operating Schedule of anticipated major activities and needs for logging Included Timber, such as logging, road maintenance, Scaling, and road construction, including construction staking under B5.212 and material delivery under B5.22. Upon reasonable notice to Forest Service, such schedule shall be subject to modifications necessi- xxxxx by weather, markets, or other unpredictable circum- stances.
Synchronization, Commissioning and Commercial Operation 4.1.1 The Power Producer shall give at least fifteen (15) days written notice to the SLDC / ALDC / DISCOM as the case may be, of the date on which it intends to synchronize the Power Project to the Grid System. 4.1.2 Subject to Article 4.1.1, the Power Project may be synchronized by the Power Producer to the Grid System when it meets all the connection conditions prescribed in the Grid Code and otherwise meets all other Indian legal requirements for synchronization to the Grid System. 4.1.3 The synchronization equipment and all necessary arrangements / equipment including Remote Terminal Unit (RTU) for scheduling of power generated from the Project and transmission of data to the concerned authority as per applicable regulation shall be installed by the Power Producer at its generation facility of the Power Project at its own cost. The Power Producer shall synchronize its system with the Grid System only after the approval of GETCO / SLDC / ALDC and GEDA. 4.1.4 The Power Producer shall immediately after each synchronization / tripping of generator, inform the sub-station of the Grid System to which the Power Project is electrically connected in accordance with applicable Grid Code. 4.1.5 The Power Producer shall commission the Project within SCOD. 4.1.6 The Power Producer shall be required to obtain Developer and/ or Transfer Permission, Key Plan drawing etc, if required, from GEDA. In cases of conversion of land from Agricultural to Non-Agriculture, the commissioning shall be taken up by GEDA only upon submission of N.A. permission by the Power Producer. 4.1.7 The Power Producer shall be required to follow the Forecasting and Scheduling procedures as per the Regulations issued by Hon’ble GERC from time to time. It is to clarify that in terms of GERC (Forecasting, Scheduling, Deviation Settlement and Related Matters of Solar and Wind Generation Sources) Regulations, 2019 the procedures for Forecasting, Scheduling & Deviation Settlment are applicable to all solar generators having combined installed capacity above 1 MW connected to the State Grid / Substation including those connected via pooling stations.
Post-Commercial Operation Date Testing and Modifications Each Party shall at its own expense perform routine inspection and testing of its facilities and equipment in accordance with Good Utility Practice as may be necessary to ensure the continued interconnection of the Large Generating Facility with the Participating TO’s Transmission System in a safe and reliable manner. Each Party shall have the right, upon advance written notice, to require reasonable additional testing of the other Party’s facilities, at the requesting Party’s expense, as may be in accordance with Good Utility Practice.