Interior Electrical System Sample Clauses

Interior Electrical System. COVERED: All Interior AC Wiring including Receptacles, Switches, Fuses, Single and Two Pole Breakers. NOT COVERED: Fixtures; attic or whole house exhaust fans; door bells; intercom systems; alarm systems; central vacuum systems; audio/video/computer wiring or cable; direct current (DC) wiring and systems; exterior wiring and components; telephone wiring; inadequate wiring capacity; power failure/shortage or surge; low voltage systems (including wiring and relays); load control devices; electrical generation systems; solar electrical systems; timers; touch pad assemblies; remote controls or failure caused by circuit overload.
AutoNDA by SimpleDocs
Interior Electrical System. COVERED: all interior AC wiring including receptacles, switches, fuses, single and two pole breakers. NOT COVERED: All other components, including but not limited to: Fixtures; attic or whole house exhaust fans; door bells; intercom systems; alarm systems; central vacuum systems; audio/video/computer wiring or cable; direct current (DC) wiring and systems; exterior wiring and components; telephone wiring; inadequate wiring capacity; power failure/shortage or surge; low voltage systems (including wiring and relays); load control devices; electrical generation systems; solar electrical systems; timers; touch pad assemblies; remote controls or failure caused by circuit overload.
Interior Electrical System. Includes interior wiring, fuse or breaker panels, switches and receptacles. Excludes lighting and electrical fixtures, power vents, bathroom heaters, and fans, telephone, low voltage wiring, and problems caused by overload situations or code violations. pressure and storage tanks, well casings, exterior electrical lines or piping, pulling pump, redrilling or deepening of xxxxx.

Related to Interior Electrical System

  • Electrical Equipment Residents must use only CSA, UL-approved or Canadian-certified electrical equipment; the rated wattage of light fixtures must never be exceeded; and only replacement bulbs supplied by Waterloo maintenance staff may be used. Do not leave any unattended electrical equipment turned on (i.e. hair straighteners, lights etc.)

  • Electrical Safety Only UL approved items are permitted in Housing & Residence Life. Extension and multi-use cords must be heavy duty, single plug, and be UL approved. Altering or adapting electrical outlets and equipment and overloading circuits jeopardize safety and thus are not permitted.

  • Electrical Provide drawings for the following systems:

  • Lighting A system of fixtures providing or controlling the light sources used on or near the airport or within the airport buildings. The field lighting includes all luminous signals, markers, floodlights, and illuminating devices used on or near the airport or to aid in the operation of aircraft landing at, taking off from, or taxiing on the airport surface.

  • HVAC A. Heating, ventilating and air conditioning equipment will be provided with sufficient capacity to accommodate a maximum population density of one (1) person per one hundred fifty (150) square feet of useable floor area served, and a combined lighting and standard electrical load of 3.0 xxxxx per square foot of useable floor area. In the event Tenant introduces into the Premises personnel or equipment which overloads the system’s ability to adequately perform its proper functions, Landlord shall so notify Tenant in writing and supplementary system(s) may be required and installed by Landlord at Tenant’s expense, if within fifteen (15) days Tenant has not modified its use so as not to cause such overload. Operating criteria of the basic system shall not be less than the following:

  • Irrigation Systems The Project Area either has no irrigation system or a low-volume drip irrigation system. If a watering system is used, it is a drip irrigation system equipped with a filter, pressure regulator and emitters rated at twenty (20) gallons per hour (gph) or less. The system is maintained free of leaks and malfunctions. No spray irrigation is applied to the Project Area, including spray from irrigation systems adjacent to the Project Area.

  • Installation, Maintenance, Testing and Repair Unless otherwise agreed in writing by the Parties, to the extent required by Applicable Law, Interconnection provided by a Party shall be equal in quality to that provided by such Party to itself, any subsidiary, affiliates or third party. If either Party is unable to fulfill its obligations under this Section 14.2, it shall notify the other Party of its inability to do so and will negotiate alternative intervals in good faith. The Parties agree that to the extent required by Applicable Law, the standards to be used by a Party for isolating and clearing any disconnections and/or other outages or troubles shall be at parity with standards used by such Party with respect to itself, any subsidiary, affiliate or third party.

  • Drainage Systems (1) Clear culvert inlets, outlets, and sediment catching basins.

  • Electrical Service Electrical service for new construction or a renovated existing building shall be 480/277-volt, 3-phase, 4-wire or approved equal. Service shall be sized for HVAC and other mechanical system(s) loads, lighting, general building services, and dedicated computer based office equipment loads. 5 xxxxx per square foot shall be provided for lighting and general service receptacles. Size of neutral conductor of 3- phase circuits shall be twice that of phase conductor to accommodate potential harmonic currents associated with computer system electronic power supplies and fluorescent lighting fixtures electronic ballasts. An adequately sized 3 phase “wye” wound step down transformer shall be provided to supply 208/120-volt, 3 phase power, for lighting, general service receptacles and dedicated computer based office equipment. Dedicated, isolated ground circuits shall be supplied from separate isolated ground power distribution panel(s). Lighting circuits shall be supplied from separate lighting panel(s). Panels shall have 20% spare capacity and be complete with 10% spare breakers of each size, but no less than 1 spare. No more than 4 duplex receptacles shall be connected to any single 20-amp dedicated isolated ground circuit or general service circuit.

  • Janitorial Services or Building Maintenance Services If this Agreement is for janitorial or building maintenance services, this section is applicable. If this Agreement requires Contractor to perform Services at a new site, Contractor shall retain for sixty (60) days all employees currently employed at that site by any previous contractor that performed the same services at the site. Contractor shall provide upon request information sufficient to identify employees providing janitorial or building maintenance services at each site and to make the necessary notifications required under Labor Code section 1060 et seq.

Time is Money Join Law Insider Premium to draft better contracts faster.