Interconnection Customer Drawings Within one hundred twenty (120) days after the date of Initial Operation, unless the Interconnection Parties agree on another mutually acceptable deadline, the Interconnection Customer shall deliver to the Transmission Provider and the Interconnected Transmission Owner final, “as-built” drawings, information and documents regarding the Customer Interconnection Facilities, including, as and to the extent applicable: a one-line diagram, a site plan showing the Customer Facility and the Customer Interconnection Facilities, plan and elevation drawings showing the layout of the Customer Interconnection Facilities, a relay functional diagram, relaying AC and DC schematic wiring diagrams and relay settings for all facilities associated with the Interconnection Customer's step-up transformers, the facilities connecting the Customer Facility to the step-up transformers and the Customer Interconnection Facilities, and the impedances (determined by factory tests) for the associated step-up transformers and the Customer Facility. As applicable, the Interconnection Customer shall provide Transmission Provider and the Interconnected Transmission Owner specifications for the excitation system, automatic voltage regulator, Customer Facility control and protection settings, transformer tap settings, and communications.
Line Outage Costs Notwithstanding anything in the NYISO OATT to the contrary, the Connecting Transmission Owner may propose to recover line outage costs associated with the installation of Connecting Transmission Owner’s Attachment Facilities or System Upgrade Facilities or System Deliverability Upgrades on a case-by-case basis.
_CheckoutDate_ _CheckoutTime_ Rental $_Rental_ Fees $_Fees_ Taxes $_AreaTax_ Total $_NetAmount_ Security Deposit $_RefundableSecurityDeposit_ Deposit $_DepositAmount_ (due _DepositDueDate_) Balance $_BalanceAmount_ (due _BalanceDueDate_)
Line Information Database (LIDB 9.1 BellSouth will store in its Line Information Database (LIDB) records relating to service only in the BellSouth region. The LIDB Storage Agreement is included in this Attachment as Exhibit C. 9.2 BellSouth will provide LIDB Storage upon written request to <<customer_name>>’s Account Manager stating a requested activation date.
Grid The salary level for each benchmark is identified as a “grid” and the corresponding dollar amount is in Wage Schedules – Grids of the Maintenance Plan. For example: Grid: 9 Wage Schedules - Grids - April 1, 2013 $2,923 per month
ELECTRONIC WORKFLOW SYSTEM OGS reserves the right to incorporate an electronic workflow system that may include elements of the Authorized User RFQ process. OGS reserves the right to post Authorized User Contract usage of Centralized Contracts. For Lot 4 only, when provided for in the RFQ and resultant Authorized User Agreement, the Authorized Users may reimburse travel expenses. All rules and regulations associated with this travel can be found at xxxx://xxx.xxxxx.xx.xx/agencies/travel/travel.htm. In no case will any travel reimbursement be charged that exceeds these rates. All travel will be paid only as specified within the Authorized User Agreement and must be billed with the associated services on the same Invoice with receipts attached. The Contractor shall receive prior approval from the Authorized User for any travel that occurs during the term of an Authorized User Agreement. Parking fees and/or parking tickets shall not be paid by an Authorized User. Unless otherwise specified in writing by the Authorized User, a vehicle will not be provided by Authorized User to the Contractor for travel. Therefore, the Contractor will be responsible for ensuring that the Contractor has access to an appropriate vehicle (e.g., personal vehicle or rental vehicle) or common carrier with which to carry out any necessary travel. For the Contractor to obtain reimbursement for the use of a rental vehicle, such use must be justified as the most cost- effective mode of transportation under the circumstances (including consideration of the most effective use of time). The Contractor is responsible for keeping adequate records to substantiate any claims for travel reimbursement. All services provided under the resultant Authorized User Agreement must be performed within CONUS. There are no BONDS for this Contract. However, an Authorized User may require in an RFQ a performance, payment or Bid bond, or negotiable irrevocable letter of credit or other form of security for the faithful performance for the resultant Authorized User Agreement. Pursuant to New York State Executive Law Article 15-A and Parts 140-145 of Title 5 of the New York Codes, Rules and Regulations (“NYCRR”), the New York State Office of General Services (“OGS”) is required to promote opportunities for the maximum feasible participation of New York State-certified Minority- and Women-owned Business Enterprises (“MWBEs”) and the employment of minority group members and women in the performance of OGS contracts.
Originating Switched Access Detail Usage Data A category 1101XX record as defined in the EMI Telcordia Practice BR-010-200- 010.
Line Information Database LIDB is a transaction-oriented database accessible through Common Channel Signaling (CCS) networks. For access to LIDB, ONS must purchase appropriate signaling links pursuant to Section 10 of this Attachment. LIDB contains records associated with End User Line Numbers and Special Billing Numbers. LIDB accepts queries from other Network Elements and provides appropriate responses. The query originator need not be the owner of LIDB data. LIDB queries include functions such as screening billed numbers that provides the ability to accept Collect or Third Number Billing calls and validation of Telephone Line Number based non-proprietary calling cards. The interface for the LIDB functionality is the interface between BellSouth’s CCS network and other CCS networks. LIDB also interfaces to administrative systems.
Activation We will notify the Xxxxxx of your request to receive electronic billing information. The presentment of your first electronic bill may vary from Xxxxxx to Xxxxxx and may take up to sixty (60) days, depending on the billing cycle of each Xxxxxx. While your electronic bill feature is being activated it is your responsibility to keep your accounts current. Each electronic Xxxxxx reserves the right to accept or deny your request to receive electronic bills.
Provisioning Line Splitting and Splitter Space 3.8.1 The Data LEC, Voice CLEC or BellSouth may provide the splitter. When Southern Telecom or its authorized agent owns the splitter, Line Splitting requires the following: a non-designed analog Loop from the serving wire center to the NID at the End User’s location; a collocation cross connection connecting the Loop to the collocation space; a second collocation cross connection from the collocation space connected to a voice port; the high frequency spectrum line activation, and a splitter. The Loop and port cannot be a Loop and port combination (i.e. UNE-P), but must be individual stand-alone Network Elements. When BellSouth owns the splitter, Line Splitting requires the following: a non designed analog Loop from the serving wire center to the NID at the End User’s location with CFA and splitter port assignments, and a collocation cross connection from the collocation space connected to a voice port. 3.8.2 An unloaded 2-wire copper Loop must serve the End User. The meet point for the Voice CLEC and the Data LEC is the point of termination on the MDF for the Data LEC's cable and pairs. 3.8.3 The foregoing procedures are applicable to migration to Line Splitting Service from a UNE-P arrangement, BellSouth Retail Voice Service, BellSouth High Frequency Spectrum (CO Based) Line Sharing. 3.8.4 For other migration scenarios to line splitting, BellSouth will work cooperatively with CLECs to develop methods and procedures to develop a process whereby a Voice CLEC and a Data LEC may provide services over the same Loop.