Measurement of LNG Sample Clauses

Measurement of LNG. LNG delivered by Seller to Buyer under this Agreement at the LNG Delivery Point or the Alternate LNG Delivery Point shall be measured in accordance with the procedures set forth in Section 1 of this Exhibit 9.1. (a) The volume of LNG received by Buyer shall exclude the amount of Return Gas returning to Seller's LNG Tanker. (b) The volume of LNG received at the LNG Delivery Point or Alternate LNG Delivery Point by Buyer shall be measured in Cubic Meters by difference between gauging of the liquid in the tanks of Seller's LNG Tanker before and after unloading. Seller shall cause the first gauging to be made after the Master of Seller's LNG Tanker has given his Notice of Readiness to unload and immediately before starting the pumps. The level shall be determined by taking five (5) readings with a time interval of 15 seconds or less between readings. The arithmetic mean of the five readings shall be the level used. While the readings are being taken, the tank being measured shall remain static.
AutoNDA by SimpleDocs
Measurement of LNG. LNG delivered by Seller to Buyer under this Agreement at the LNG Delivery Point shall be measured in accordance with the procedures set forth in this Exhibit 9.3. (a) The volume of LNG received by Buyer shall exclude the amount of Return Gas returning to Seller's LNG Tanker ("Return Gas") during the unloading of LNG. (b) The volume of Cubic Meters of LNG received at the LNG Delivery Point shall be measured in metric units by gauging of the liquid in the tanks of Seller's LNG Tanker. Seller shall cause the first gauging to be made after the Master of Seller's LNG Tanker has given his Notice of Readiness to unload and immediately before starting the pumps. A second gauging shall take place immediately after completion of unloading. Representatives of Seller, Buyer and Southern LNG shall have the right to be present at such gaugings, but the absence of a representative shall not prohibit any gauging.

Related to Measurement of LNG

  • Usage Measurement Usage measurement for calls shall begin when answer supervision or equivalent Signaling System 7 (SS7) message is received from the terminating office and shall end at the time of call disconnect by the calling or called subscriber, whichever occurs first.

  • Mileage Measurement Where required, the mileage measurement for LIS rate elements is determined in the same manner as the mileage measurement for V&H methodology as outlined in NECA Tariff No. 4.

  • Covenants of Performance Measurement No interference. Registry Operator shall not interfere with measurement Probes, including any form of preferential treatment of the requests for the monitored services. Registry Operator shall respond to the measurement tests described in this Specification as it would to any other request from an Internet user (for DNS and RDDS) or registrar (for EPP). ICANN testing registrar. Registry Operator agrees that ICANN will have a testing registrar used for purposes of measuring the SLRs described above. Registry Operator agrees to not provide any differentiated treatment for the testing registrar other than no billing of the transactions. ICANN shall not use the registrar for registering domain names (or other registry objects) for itself or others, except for the purposes of verifying contractual compliance with the conditions described in this Agreement. PUBLIC INTEREST COMMITMENTS Registry Operator will use only ICANN accredited registrars that are party to the Registrar Accreditation Agreement approved by the ICANN Board of Directors on 27 June 2013 in registering domain names. A list of such registrars shall be maintained by ICANN on ICANN’s website. (Intentionally omitted. Registry Operator has not included commitments, statements of intent or business plans provided for in its application to ICANN for the TLD.) Registry Operator agrees to perform the following specific public interest commitments, which commitments shall be enforceable by ICANN and through the Public Interest Commitment Dispute Resolution Process established by ICANN (posted at xxxx://xxx.xxxxx.xxx/en/resources/registries/picdrp), which may be revised in immaterial respects by ICANN from time to time (the “PICDRP”). Registry Operator shall comply with the PICDRP. Registry Operator agrees to implement and adhere to any remedies ICANN imposes (which may include any reasonable remedy, including for the avoidance of doubt, the termination of the Registry Agreement pursuant to Section 4.3(e) of the Agreement) following a determination by any PICDRP panel and to be bound by any such determination. Registry Operator will include a provision in its Registry-Registrar Agreement that requires Registrars to include in their Registration Agreements a provision prohibiting Registered Name Holders from distributing malware, abusively operating botnets, phishing, piracy, trademark or copyright infringement, fraudulent or deceptive practices, counterfeiting or otherwise engaging in activity contrary to applicable law, and providing (consistent with applicable law and any related procedures) consequences for such activities including suspension of the domain name. Registry Operator will periodically conduct a technical analysis to assess whether domains in the TLD are being used to perpetrate security threats, such as pharming, phishing, malware, and botnets. Registry Operator will maintain statistical reports on the number of security threats identified and the actions taken as a result of the periodic security checks. Registry Operator will maintain these reports for the term of the Agreement unless a shorter period is required by law or approved by ICANN, and will provide them to ICANN upon request. Registry Operator will operate the TLD in a transparent manner consistent with general principles of openness and non-discrimination by establishing, publishing and adhering to clear registration policies.

  • Performance Measurement The Uniform Guidance requires completion of OMB-approved standard information collection forms (the PPR). The form focuses on outcomes, as related to the Federal Award Performance Goals that awarding Federal agencies are required to detail in the Awards.

  • Cash Flow Leverage Ratio The Borrower will not permit the Cash Flow Leverage Ratio on the last day of any fiscal quarter to exceed 3.50 to 1.00.

  • Temperature Measurement Temperature will be measured by the nearest automatic Melbourne Bureau of Meteorology Monitoring Station for example (but not limited to): Melbourne, Moorabbin, Dunns Hill, Melbourne Airport, Frankston, and Point Xxxxxx. At the commencement of each project, the onsite management and employee representatives shall agree which is to be the applicable automatic weather monitoring station.

  • Early Construction of Base Case Facilities Developer may request Connecting Transmission Owner to construct, and Connecting Transmission Owner shall construct, subject to a binding cost allocation agreement reached in accordance with Attachment S to the ISO OATT, including Section 25.8.7 thereof, using Reasonable Efforts to accommodate Developer’s In-Service Date, all or any portion of any System Upgrade Facilities or System Deliverability Upgrades required for Developer to be interconnected to the New York State Transmission System which are included in the Base Case of the Class Year Study for the Developer, and which also are required to be constructed for another Developer, but where such construction is not scheduled to be completed in time to achieve Developer’s In-Service Date.

  • Measurement Should the State terminate this contract as herein provided, no fees other than fees due and payable at the time of termination shall thereafter be paid to the Engineer. In determining the value of the work performed by the Engineer prior to termination, the State shall be the sole judge. Compensation for work at termination will be based on a percentage of the work completed at that time. Should the State terminate this contract under paragraph (4) or (5) above, the Engineer shall not incur costs during the thirty-day notice period in excess of the amount incurred during the preceding thirty days.

  • Total Net Leverage Ratio Holdings and its Restricted Subsidiaries, on a consolidated basis, shall not permit the Total Net Leverage Ratio on the last day of any Test Period to exceed the ratio set forth below opposite the last day of such Test Period:

  • Maximum Consolidated Leverage Ratio The Consolidated Leverage Ratio at any time may not exceed 0.75 to 1.00; and

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!