Measurement of Net Energy Output and Dependable Capacity Sample Clauses

Measurement of Net Energy Output and Dependable Capacity. 8.3.1 On the Commercial Operations Date and each Month thereafter, JPS shall read the Primary Metering System for the purpose of measuring the Net Energy Output and Dependable Capacity of the Facility in accordance with the provisions of Schedule 5. If JPS obtains readings remotely, JPS shall make copies of the reading produced by the device which initiates the reading protocol and provide a copy of such reading to the Company on the Day of such reading. JPS shall provide details of the reading protocol and/or remote reading procedures to the Company. If JPS conducts a physical reading of the Primary Metering System, it shall permit a representative of the Company to witness and verify such reading; provided, however, that the failure of the Company to send a representative to witness any such reading shall not affect the validity of such inspection or test or reading. 8.3.2 If the Primary Metering System is found to be inaccurate or functioning improperly, JPS shall read the Back-up Metering System, in accordance with the provisions of Schedule 5 for the purpose of measuring the Net Energy Output and Dependable Capacity of the Facility. 8.3.3 In the event that the Primary Metering System and the Back-up Metering System are found to be inaccurate or functioning improperly, the correct amount of Net Energy Output delivered to JPS during the period for which inaccurate measurements were made shall be determined in accordance with Schedule 5. The difference between the previous payments by JPS for the period of inaccuracy and the recalculated amount shall be offset against or added to the next payment to the Company under this Agreement, as appropriate; provided, however, that if there are no scheduled future payments, then the Company or JPS, as the case may be, shall pay the other Party the adjustment amount within thirty (30) Days. In no event, however, shall any such adjustment be made for any period prior to the date on which the Primary Metering System was last tested and found to be accurate within plus or minus [METER ACCURACY] percent ([METER ACCURACY]%) and not otherwise functioning improperly. 8.3.4 Within fourteen (14) Days after (a) the first (1st) anniversary of the Commercial Operations Date and (b) the end of each six (6) Month interval thereafter, the Company shall perform, at its sole cost and expense, a test of the Dependable Capacity in accordance with the provisions of Schedule 4 for the purpose of measuring the Dependable Capacity.
AutoNDA by SimpleDocs

Related to Measurement of Net Energy Output and Dependable Capacity

  • Interconnection Customer’s Interconnection Facilities The Interconnection Customer shall design, procure, construct, install, own and/or control the Interconnection Customer’s Interconnection Facilities described in Appendix A at its sole expense.

  • Interconnection Customer Provided Services The services provided by Interconnection Customer under this LGIA are set forth in Article 9.6 and Article 13.5. 1. Interconnection Customer shall be paid for such services in accordance with Article 11.6.

  • Interconnection Customer Compensation If the CAISO requests or directs the Interconnection Customer to provide a service pursuant to Articles 9.6.3 (Payment for Reactive Power) or 13.5.1 of this LGIA, the CAISO shall compensate the Interconnection Customer in accordance with the CAISO Tariff.

  • Cost Responsibility for Interconnection Facilities and Distribution Upgrades 4.1 Interconnection Facilities 4.2 Distribution Upgrades

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

  • Interconnection Customer (1) Interconnection Customer shall construct and, unless otherwise indicated, shall own, the following Interconnection Facilities: None (2) In the event that, in accordance with the Interconnection Construction Service Agreement, Interconnection Customer has exercised the Option to Build, it is hereby permitted to build in accordance with and subject to the conditions and limitations set forth in that Section, the following portions of the Transmission Owner Interconnection Facilities which constitute or are part of the Customer Facility: None Ownership of the facilities built by Interconnection Customer pursuant to the Option to Build shall be as provided in the Interconnection Construction Service Agreement.

  • Verizon OSS Facilities Any gateways, interfaces, databases, facilities, equipment, software, or systems, used by Verizon to provide Verizon OSS Services to ICG.

  • Interconnection Facilities 4.1.1 The Interconnection Customer shall pay for the cost of the Interconnection Facilities itemized in Attachment 2 of this Agreement. The NYISO, in consultation with the Connecting Transmission Owner, shall provide a best estimate cost, including overheads, for the purchase and construction of its Interconnection Facilities and provide a detailed itemization of such costs. Costs associated with Interconnection Facilities may be shared with other entities that may benefit from such facilities by agreement of the Interconnection Customer, such other entities, the NYISO, and the Connecting Transmission Owner. 4.1.2 The Interconnection Customer shall be responsible for its share of all reasonable expenses, including overheads, associated with (1) owning, operating, maintaining, repairing, and replacing its own Interconnection Facilities, and

  • Interconnection Facility Options The Intercarrier Compensation provisions of this Agreement shall apply to the exchange of Exchange Service (EAS/Local) traffic between CLEC's network and Qwest's network. Where either Party acts as an IntraLATA Toll provider, each Party shall xxxx the other the appropriate charges pursuant to its respective tariff or price lists. Where either Party interconnects and delivers traffic to the other from third parties, each Party shall xxxx such third parties the appropriate charges pursuant to its respective tariffs, price lists or contractual offerings for such third party terminations. Absent a separately negotiated agreement to the contrary, the Parties will directly exchange traffic between their respective networks without the use of third party transit providers.

  • Independent Capacity of Contractor The Contractor and Contractor Parties shall act in an independent capacity and not as officers or employees of the state of Connecticut or of the Agency.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!