Measuring gas Sample Clauses

Measuring gas. We use meter readings that are provided to us to prepare your bill. We bill you on the amount of energy in the gas you use, not the volume of gas. To calculate your consumption, we first measure the volume of gas you use via the meter (in cubic meters or cubic feet). We then convert the volume of gas you use into units by applying a heating value. This heating value is measured by the network operator at a number of places and it can change from time to time. We may also calculate consumption through the measurement of gas from a master meter and utilise other measurement devices to calculate bills for individual usage of a product (where required).
AutoNDA by SimpleDocs
Measuring gas. The meter measures the volume of gas you use, but we will xxxx you according to the amount of energy in gas you use. {Volume is measured in cubic metres or cubic feet; energy is measured in units.} Because gas is a naturally occurring substance, the amount of energy in a given volume of gas [called the “heating value”] changes from time to time. The network operator measures the heating value of gas at a number of places, and we will use those measurements to calculate the heating value of gas you use. Then, we will use that calculated heating value to convert the meter’s volume reading into an energy value, measured in units.

Related to Measuring gas

  • Measuring DNS parameters Every minute, every DNS probe will make an UDP or TCP “DNS test” to each of the public-­‐DNS registered “IP addresses” of the name servers of the domain name being monitored. If a “DNS test” result is undefined/unanswered, the tested IP will be considered unavailable from that probe until it is time to make a new test.

  • Measurement Should the State terminate this contract as herein provided, no fees other than fees due and payable at the time of termination shall thereafter be paid to the Engineer. In determining the value of the work performed by the Engineer prior to termination, the State shall be the sole judge. Compensation for work at termination will be based on a percentage of the work completed at that time. Should the State terminate this contract under paragraph (4) or (5) above, the Engineer shall not incur costs during the thirty-day notice period in excess of the amount incurred during the preceding thirty days.

  • Measuring EPP parameters Every 5 minutes, EPP probes will select one “IP address” of the EPP servers of the TLD being monitored and make an “EPP test”; every time they should alternate between the 3 different types of commands and between the commands inside each category. If an “EPP test” result is undefined/unanswered, the EPP service will be considered as unavailable from that probe until it is time to make a new test.

  • MEASURING EQUIPMENT 1. Seller will maintain and operate, atlts own, expense and atthe point of delivery of gas hereunder, a meter or meters and othernecessary equipment by which the volume of gas delivered hereunder shall be measured. Such meters and equipment shall remain the property of the Seller. 2. Buyer agrees lo furnish to Seller electricity for operating Seller's meters, at not cost to Seller. 3. Buyer hereby grants to Seller suitable rlghts-0f-way and easements necessary or Incidental for the installatioo, maintenance, operation and removal of pipeline and other facilities together with rights ofingress thereto and egress there from at all times and hereby agrees to deliver to Seller, for the sum of one dollar ($1.00), an appropriate instrument or grant defining such rights and easements located on Buyer's planlslte. 4. Buyer may install, maintain and operate such check measuring equipment, Including arecording gravltometer and calorimeter as it shall desire, provided that such equipment shall be so installed so as not to Interfere with the operation of Seller's measuring equipment at or near the point of deliver. However, all xxxxxxxx to the Buyer shall be based on the metering of the Seller, subject only to the provisions of Paragraph 8 of this Article. 5. Each party shall have the right to be present at the time of any installing, reading, cleaning, changing, repairing, Inspecting, testing, calibrating, or adjusting done In connection with the other's measuring equlpme!lt used in measuring deliveries hereunder and each party shall advise the other of any Intended major maintenance operation sufficiently in advance in order that the other party may conveniently have its representative present. 6. All installatioo of measuring equipmenL applying to or effecting deliveries hereunder, shall be rnade in such manner as to perrnit an accurate detenninalion of the quantity of gas delivered and ready verification of the accuracy of measurement Orifice meter Installations, If used, shall oonforrn lo the recommendation for design and lnstallatioo contained in the Gas Measurement Commiltee Report No. 3 to the American Gas Association published April, 1955, and any modificatioos and amendments thereof and shall include the use of flange connections. 7. Measurement on Seller's meter or meters shall be conclusive of both parties except where the meter Is defective or fails to register, or if found in E)rror, in either of which case Seller shall repair or replace the meter and the quantity of gas delivered while the meter was out of order or failed to register shall be estimated: (a) By using the registration of any check meter If installed and accurately registering, or, In the absence of (a): (b) By correcting the error If the percentage of error by calibration, test or mathematical calculation, or, in the absence of both (a) and (b) then: (c) By estimating the quantity of delivery from deliveries during periods under similar oonditions when the meter was registering actUrately; and an appropriate billing adjusbnentshall be made In accordance with the current Rules and Regulations governing gas systems issued by the Commission. 8. Seller will maintain its meters in .good order and to this end Wiii make periodic tests of its meters pursuant to the current Rules and Regulations governing gas systems issued by the Commission, or at such shorter intervals as seem to Seller desirable. lfBuyer Is dissatisfied with the accuracy at eny time, it may call upon Seller to have Iha meter tested in accordance with all regulatioos relating to such tests and results of such tesls as found in the current Rules and Regulations governing gas systems issued by the Commission. 9. Each party shall preserve all records for aperiod of at least two (2) years.

  • Minimum Adjusted EBITDA Borrower shall maintain a minimum trailing six-month Adjusted EBITDA minus dividend distributions (other than tax distributions), as of such test date, of at least the greater of (a) $75,000,000 and (b) an amount equal to 75% of the trailing six-month Adjusted EBITDA minus dividend distributions (other than tax distributions), for the immediately preceding six-month period, tested semi-annually, commencing September 30, 2024, and continuing on each subsequent March 31 and September 30.

  • Measurement method An isolation resistance test instrument is connected between the live parts and the electrical chassis. The isolation resistance is subsequently measured by applying a DC voltage at least half of the working voltage of the high voltage bus. If the system has several voltage ranges (e.g. because of boost converter) in conductively connected circuit and some of the components cannot withstand the working voltage of the entire circuit, the isolation resistance between those components and the electrical chassis can be measured separately by applying at least half of their own working voltage with those components disconnected.

  • Temperature Measurement Temperature will be measured by the nearest automatic Melbourne Bureau of Meteorology Monitoring Station for example (but not limited to): Melbourne, Moorabbin, Dunns Hill, Melbourne Airport, Frankston, and Point Xxxxxx. At the commencement of each project, the onsite management and employee representatives shall agree which is to be the applicable automatic weather monitoring station.

  • Adjusted EBITDA The 2019 adjusted EBITDA for the Affiliated Club Sellers shall total an aggregate of not less than $10,700,000.

  • Measurement Period In this Agreement, unless the contrary intention appears, a reference to:

  • Usage Measurement Usage measurement for calls shall begin when answer supervision or equivalent Signaling System 7 (SS7) message is received from the terminating office and shall end at the time of call disconnect by the calling or called subscriber, whichever occurs first.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!