MSC FUNCTIONAL ARCHITECTURE Sample Clauses

MSC FUNCTIONAL ARCHITECTURE iDEN Mobile Services switching Center (MSC) supports three distinct interfaces to the host network or other external systems. These interfaces are: o The 'A' INTERFACE, providing linkage to Base Site Controller's (BSCs) for Mobile Stations' interconnect activity. o The MOBILE APPLICATION PART (MAP) Interface, permitting mobility information to be transferred between network level components (Location Registers and MSCs). o The PSTN INTERFACE, which provides connectivity to the PSTN. Connectivity with System BSCs, MSCs, PSTN and other PLMNs is via T1/E1 interfaces connected to the DTCs. These peripherals support both the telephony traffic and the 'A' Interface signaling channel. The signaling channels are routed through the switching matrix to an 'A' Interface LIU in a LPP. This signaling processor handles all of the 'A' Interface protocol processing and communicates with DMS-Core, for network updates and mobile call processing via the DMS-Bus. Signaling between the MSC and other MSCs, HLRs and the PSTN for network updates and telephony call control are via the CCS/C7 (CCITT) LIUs also located in the LPPs.
AutoNDA by SimpleDocs

Related to MSC FUNCTIONAL ARCHITECTURE

  • CUSTOMER SERVICE FUNCTIONS The Servicer shall handle all Customer inquiries and other Customer service matters according to the same procedures it uses to service Customers with respect to its own charges.

  • Centralized Functions The Bank of New York Mellon Corporation is a global financial organization that provides services to clients through its affiliates and subsidiaries in multiple jurisdictions (the “BNY Mellon Group”). The BNY Mellon Group may centralize functions including audit, accounting, risk, legal, compliance, sales, administration, product communication, relationship management, storage, compilation and analysis of customer-related data, and other functions (the “Centralized Functions”) in one or more affiliates, subsidiaries and third-party service providers. Solely in connection with the Centralized Functions, (i) the Fund consents to the disclosure of and authorizes the Custodian to disclose information regarding the Fund and the Accounts (“Customer-Related Data”) to the BNY Mellon Group and to its third-party service providers who are subject to confidentiality obligations with respect to such information and (ii) the Custodian may store the names and business contact information of the Fund’s employees and representatives on the systems or in the records of the BNY Mellon Group or its service providers. The BNY Mellon Group may aggregate Customer-Related Data with other data collected and/or calculated by the BNY Mellon Group, and notwithstanding anything in this Agreement to the contrary the BNY Mellon Group will own all such aggregated data, provided that the BNY Mellon Group shall not distribute the aggregated data in a format that identifies Customer-Related Data with the Fund. The Fund confirms that it is authorized to consent to the foregoing and that the disclosure and storage of information in connection with the Centralized Functions does not violate any relevant data protection legislation.

  • Program Management (WBS 1.1) All components of the Project Management Plan as implemented for the Base Contract and Options 1-4 will be reviewed and amended to reflect specific needs for Option 5 and the outcome of continuous process improvement evaluations.

  • Review Systems; Personnel It will maintain business process management and/or other systems necessary to ensure that it can perform each Test and, on execution of this Agreement, will load each Test into these systems. The Asset Representations Reviewer will ensure that these systems allow for each Review Receivable and the related Review Materials to be individually tracked and stored as contemplated by this Agreement. The Asset Representations Reviewer will maintain adequate staff that is properly trained to conduct Reviews as required by this Agreement.

  • Interfaces 1 2 wire i/f (towards PSTN) -------------------------------------------------------------------------------------------------------- 2 2 wire i/f (towards standard handset) -------------------------------------------------------------------------------------------------------- 2.2 FUNCTIONS -------------------------------------------------------------------------------------------------------- 1 Selective Call -------------------------------------------------------------------------------------------------------- 2 Conference Call (up to four participants) ----------------------------------------------------------------------------------------------------------------------------------- ----------------------------------------------------------------------------------------------------------------------------------- 3 MANAGEMENT COMMUNICATION -------------------------------------------------------------------------------------------------------- 3.1 COMMUNICATION INTERFACES see OPTera Product Description SEC. 5.2.3 - Standard Communications Interfaces and SEC.7.3 - Management Communication -------------------------------------------------------------------------------------------------------- 1 F- Interface (RS 232) -------------------------------------------------------------------------------------------------------- 2 Q- interface as gateway to the EMS -------------------------------------------------------------------------------------------------------- 3 Qecc Routing (2 level IS-IS) -------------------------------------------------------------------------------------------------------- 4 Q I/F (Ethernet) -------------------------------------------------------------------------------------------------------- 5 Optical Supervisory Channel ----------------------------------------------------------------------------------------------------------------------------------- 6 OSC - wavelength IR IR IR see OPTera Product - bitrate Description SEC. 5.2.2 - optical span limit - Per Wavelength - transmission protocol Optical Service Channel and SEC.7.3 - Management Communication ----------------------------------------------------------------------------------------------------------------------------------- ----------------------------------------------------------------------------------------------------------------------------------- 3.2 O & M INTERFACES ----------------------------------------------------------------------------------------------------------------------------------- 1 8 x Remote Control Inputs ----------------------------------------------------------------------------------------------------------------------------------- 2 Remote Control Outputs ----------------------------------------------------------------------------------------------------------------------------------- 3 Card LED support ----------------------------------------------------------------------------------------------------------------------------------- 4 Subrack LED support ----------------------------------------------------------------------------------------------------------------------------------- 5 Rack Alarm support ----------------------------------------------------------------------------------------------------------------------------------- -----------------------------------------------------------------------------------------------------------------------------------

  • Project Management With respect to each Project Plan, each party will appoint a project manager who will be the party responsible for overseeing the Project Plan.

  • Information Systems Acquisition Development and Maintenance a. Client Data – Client Data will only be used by State Street for the purposes specified in this Agreement.

  • Hosting Services GSI shall load the Web site onto server(s) that are connected to the Internet and readily accessible via the Web through use of the Domain Names. GSI shall ensure that the Web site is functional and ready to process transactions in a reasonably efficient manner.

  • Hosting Except as specifically provided in Section 2.1 above, the CBOT shall not use the Licensed Technology, or any component thereof, to facilitate the trading of any derivative product, physical commodity or financial instrument listed by (a) any U.S. domiciled “organized exchange,” “board of trade” or “trading facility” (as each such term is defined in the Commodity Futures Modernization Act of 2000) under the jurisdiction of the CFTC, other than the CBOT, or (b) any other third party exchange, board of trade, association, communication network, alternative trading system, trading facility or trading platform. For the avoidance of doubt, the foregoing limitation of the scope of the License shall not apply to Trading Applications.

  • Contract Management (a) Atlantic will appoint one individual with sufficient seniority, experience and authority to oversee the Atlantic's performance under this Agreement (the Atlantic "Contract Manager") and, for periods when any Contract Manager is absent due to illness or vacation, a deputy for him or her, who will be the primary point of contact for the Executive Officers. One of the Trust's trustees, PEO, PFO, or such other Person designated by the Board from time to time, shall be the Trust's "Contract Manager". The Contract Managers for each Party shall be responsible for the overall management of this Agreement. Subject to and as contemplated by this Agreement, the Contract Managers or their deputies will have the authority and be given the primary responsibility to:

Time is Money Join Law Insider Premium to draft better contracts faster.