New Software Protection Method Sample Clauses

New Software Protection Method. If you have used dongles of other types, please try your best to forget the technical details of those dongles and digest the contents of this section, because this is a cutting-edge and brand new notion. If you have never used any dongle before, take a look at the picture below and you will find the whole process quite easy to understand. Do remember that there are no such concepts as ―data area‖, ―algorithm unit‖, etc., which are all outdated. Now your dongle is provided with a complete ―operating system‖ consisting of all files: executable files, data files and key files as well as directories, of course. You can imagine it as a MS-DOS operating system. Next let us take a look at how software protection is achieved (Figure 1-1).
AutoNDA by SimpleDocs

Related to New Software Protection Method

  • NETWORK INTERCONNECTION METHODS 64.1 This Section sets forth the terms and conditions for Network Interconnection Methods (NIMs) provided between CenturyLink and CLEC for the Interconnection Facilities established between the Parties’ networks. Additionally, this Section describes the physical architecture for the Interconnection of the Parties’ facilities and equipment required for the transmission and routing of Local Traffic, ISP-Bound Traffic, IntraLATA LEC Toll Traffic, VoIP-PSTN Traffic, Transit Traffic and Jointly Provided Switched Access Service Traffic.

  • Software Use Case Red Hat Enterprise Virtualization Supported on physical hardware solely to support virtual quests. Red Hat Enterprise Virtualization is designed to run and manage virtual instances and does not support user-space applications. Red Hat Enterprise Virtualization may be used as a virtual desktop infrastructure solution, however, the Subscription does not come with any software or support for the desktop operating system. You must purchase the operating system for each instance of a desktop or server separately.

  • Network Access TENANT may find it necessary to purchase a network interface card, wireless PC card or other hardware in order to connect to the internet service. LANDLORD is not responsible for the purchase of these items and LANDLORD cannot guarantee compatibility with any device TENANT may have. The computer and network card must have software installed that supports the Internet Protocol commonly referred to as TCP/IP. Any conflicts between the software compatibility of the network and the TENANT’S computer operating system or any other feature will be the responsibility of the TENANT to resolve. LANDLORD will not be responsible for software issues related to the user’s personal computer.

  • Software Use Case Red Hat Enterprise Linux Developer Suite Subscription Services for Red Hat Enterprise Linux Developer Suite are available for Development Purposes only.

  • Software Updates XXXXX agrees to keep current with software licensed from Skyward and will install new versions on a timeline approved by XXXXX governance. This timeline will be communicated by NWRDC to the Districts. School District Workstations Configuration requirements for devices and their software that school district personnel use to access WSIPC’s software modules can be found on our website: xxxxx://xxx.xxxxx.xxx/technology‐team/. State Reports XXXXX will provide, at no additional fee, all data reports required by the state that impact 50% or more of the school districts in the state. WSIPC and NWRDC will work with state agencies to gather requirements on the required data. WSIPC will inform NWRDC staff of any mandated changes to state reports and NWRDC will communicate the information to the District. Appendix B NWRDC FTE Fees Fiscal Only NWRDC Software Support Services XXXXX Software Licensing Total FTE Fee $13.63 $20.34 $33.97 $15.56 $13.08 $28.64 $24.52 $20.34 $44.86 Student Only Full Service

  • Construction Methods No four course of brick-work, with three joints, shall exceed in height, when built, one inch more than the same bricks piles upon one another without mortar. The bricks are to be well soaked in water before use on works, in proper through so as to be thoroughly wet when layed. The Cessation of the bubbles through the water is an irldication of saturation being complete. For ensuring thorough soaking of the bricks every one or two bricklayers or more as necessary, shall be provided with tubs for use The wall of structures shall be carried up regularly in all cases 1` when the nature of the work will admit of it not leaving any part 915mm (3 feet) lower than another. Horizontal courses shalI be straight, level and even and faces of walls smooth and plumb. A straight edge and a plumb- xxx shall be used for constant checking during progress of the work. No brick-bats shall be permitted to be used except when necessary for obtaining the dimension of the different course or for obtaining the specified bond. All unfinished work must be raked back in course unless otherwise directed arid when new work is to be jointed to it the surface of unfinished work must be cleaned and wetted. The bricks shall be laid by placing sufficient mortar on the wall and forcing every brick into it in such a manner as to completely fill every joint with moratar whether at the bottom, side or end of the brick. The mortar to be used shall be that specified for the relevant schedule items and shall comply with the specification for the mortar specified. The bound used shall be English and shall be carried throughout the work. At all angles forming the junction of any two walls, the bricks shall, at each alternate course be carried into each of the respective walls, so as to thoroughly unite the work. V'Jhen the faces are to be plastered, the joints shall be well raked out before any plaster is laid on should the plaster from want of proper joint ranking detach and 7 fall off from the brick work, the contractor shall strip off the plaster bodily to the extent ordered by Superintending Engineer and shall re-do the work properly at his own expense. All requisite scaffolding shall be provided at the contractor's expense and shall be double i.e., must it have two sets of upright supports Care must be taken to ensure the safety of the work people and the contractor must comply with such instructions as the Superintending Engineer may issue to ensure such safety. The contractor will be entirely responsible for any damage or injuries to person or property resulting from ill-erected scaffolding, defective ladders, or otherwise arising out of his default in this respect. The brick work for the retaining wall shall proceed side by side with the depositing and compacting of earth between the retaining walls. At no time shall the brick-work be constructed more than 405mm (1'-4") above Y the compacted earth. In the retaining wall weep-holes shall be provided at suitable intervals as instructed during execution, with the inner surface of the weep-holed plastered 20mm (3/4") thick in cement mortar 1:4 crouched rock of grades in different layer shall be provided at the inner end of the weep-holes to prevent the choking of the weep-holes to have full drainage. No extra payment will be made for this and no deductions will be made for this in the brick-work.

  • Software Services If elected by Customer, the following Software Services will be made available for Customer’s use.

  • Use of local labour professional services and materials 10. (1) The Company shall, for the purposes of this Agreement —

  • Software Upgrades Software Upgrades consist of new product releases which are issued periodically and may include new functionality, enhancements, and bug fixes. Software Upgrades are provided only for standard hardware platforms and operating systems supported by COMSPOC as described in the Documentation. Software Upgrades will apply only to unmodified Software and commercially released updated versions of the Software. You are responsible for making or arranging for updates to interfaces for nonstandard devices or custom applications. Software Upgrades are provided subject to the terms and conditions of the then current and applicable COMSPOC Software License Agreement, available on COMSPOC’s website at xxxx://xxx.xxxxxxx.xxx/sla or with the deliverable Software or upon request. All major product releases and maintenance releases will be made available and may be shipped directly to you, upon request by contacting your COMSPOC point of contact or xxxxxxx@xxxxxxx.xxx. You may upgrade to the latest product version at any time during the term of the Annual Support and Upgrades Agreement. If you opt not to renew the Annual Support and Upgrade Agreement, You have 60 days from the end of the Annual Support and Upgrades Agreement term to upgrade to the latest product version available prior to the end of the Annual Support and Upgrades Agreement term. If You request an upgrade beyond this 60-day period, You will be required to renew the Annual Support and Upgrades Agreement in order to upgrade to the latest product version.

  • Access to Network Interface Device (NID 2.4.3.1. Due to the wide variety of NIDs utilized by BellSouth (based on subscriber size and environmental considerations), Mpower may access the on-premises wiring by any of the following means: BellSouth shall allow Mpower to connect its loops directly to BellSouth’s multi-line residential NID enclosures that have additional space and are not used by BellSouth or any other telecommunications carriers to provide service to the premise. Mpower agrees to install compatible protectors and test jacks and to maintain the protection system and equipment and to indemnify BellSouth pursuant to Section 8 of the General Terms and Conditions of this Agreement.

Time is Money Join Law Insider Premium to draft better contracts faster.