Performance Standards for Heating and Cooling Functions Sample Clauses

Performance Standards for Heating and Cooling Functions. (1) A heating system shall produce an inside temperature of at least 68-degrees Fahrenheit as measured two feet from the outside wall of a room at a height of three feet above the floor under local outdoor winter design conditions as specified in the Code. (A) If a heating system fails to perform to the standard stated in paragraph (1) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard. (B) Temperatures may vary up to 4-degrees Fahrenheit between rooms but no less than the standard set forth above in paragraph (1) of this subsection. The homeowner’s changes made to the size or configuration of the home, the heating system or the ductwork shall negate the builder’s responsibility to take measures to meet this performance standard. (2) An air-conditioner system shall produce an inside temperature of at most 78-degrees Fahrenheit as measured in the center of a room at height of five feet above the floor, under local outdoor summer design conditions as specified in the Code. (A) If the air-conditioner system fails to perform to the standard stated in paragraph (2) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard. (B) This standard does not apply to evaporative or other alternative cooling systems or if the homeowner makes changes to the size or configuration of the home, the air-conditioning system or the ductwork. Internal temperatures may vary up to 4-degrees Fahrenheit between rooms but no more than the standard set forth above in paragraph (2) of this subsection. (3) A thermostat reading shall not differ by more than 4-degrees Fahrenheit from the actual room temperature taken at a height of five feet above the floor in the center of the room where the thermostat is located. The stated performance standard is related to the accuracy of the thermostat and not to the performance standard of the room temperature. If the thermostat reading differs more than 4-degrees Fahrenheit from the actual room temperature taken at a height of five feet above the floor in the center of the room where the thermostat is located, the builder shall take such action as is necessary to bring the variance within the standard. (4) Heating and cooling equipment shall be installed and secured according to the manufacturer’s instructions and specification and shall not move excessively. If the heating or cooling equipment is not installed and secured in accorda...
AutoNDA by SimpleDocs
Performance Standards for Heating and Cooling Functions. A heating system shall produce an inside temperature of at least 68-degrees Fahrenheit as measured two feet from the outside wall of a room at a height of three feet above the floor under local outdoor winter design conditions as specified in the Code.

Related to Performance Standards for Heating and Cooling Functions

  • Performance Standards The Contractor agrees to perform all tasks and provide deliverables as set forth in the Contract. The Department and the Customer will be entitled at all times, upon request, to be advised as to the status of work being done by the Contractor and of the details thereof.

  • CUSTOMER SERVICE FUNCTIONS The Servicer shall handle all Customer inquiries and other Customer service matters according to the same procedures it uses to service Customers with respect to its own charges.

  • PERFORMANCE MONITORING AND REPORTING Performance indicators

  • Money Market Fund Compliance Testing and Reporting Services Subject to the authorization and direction of the Trust and, in each case where appropriate, the review and comment by the Trust’s independent accountants and legal counsel, and in accordance with procedures that may be established from time to time between the Trust and the Administrator, the Administrator will:

  • Quality Service Standards Price Services and the Fund may from time to time agree to certain quality service standards, as well as incentives and penalties with respect to Price Services’ Services hereunder.

  • Performance Reporting The State of California is required to submit the following financial reports to FEMA:

  • Servicing and Maintenance Standards On behalf of the Issuer, the Servicer shall (a) manage, service, administer, bill, collect and calculate Securitized Utility Tariff Charges in accordance with the Securitization Law and post collections in respect of the Securitized Utility Tariff Property with reasonable care and in material compliance with applicable Requirements of Law, including all applicable MPSC Regulations and guidelines, using the same degree of care and diligence that the Servicer exercises with respect to similar assets for its own account and, if applicable, for others; (b) follow customary standards, policies and procedures for the industry in Missouri in performing its duties as Servicer; (c) use all reasonable efforts, consistent with its customary servicing procedures, to enforce, and maintain rights in respect of, the Securitized Utility Tariff Property and to bill and collect the Securitized Utility Tariff Charges; (d) comply with all Requirements of Law, including all applicable MPSC Regulations and guidelines, applicable to and binding on it relating to the Securitized Utility Tariff Property; (e) file all MPSC notices described in the Securitization Law and file and maintain the effectiveness of UCC financing statements with respect to the property transferred under the Sale Agreement, and (f) take such other action on behalf of the Issuer to ensure that the Lien of the Indenture Trustee on the Securitized Utility Tariff Collateral remains perfected and of first priority. The Servicer shall follow such customary and usual practices and procedures as it shall deem necessary or advisable in its servicing of all or any portion of the Securitized Utility Tariff Property, which, in the Servicer’s judgment, may include the taking of legal action, at the Issuer’s expense but subject to the priority of payments set forth in Section 8.02(e) of the Indenture.

  • Safeguards Monitoring and Reporting The Borrower shall do the following or cause the Project Executing Agency to do the following:

  • Quality Standards Each Party agrees that the nature and quality of its products and services supplied in connection with the other Party's Marks will conform to quality standards set by the other Party. Each Party agrees to supply the other Party, upon request, with a reasonable number of samples of any Materials publicly disseminated by such Party which utilize the other Party's Marks. Each Party will comply with all applicable laws, regulations, and customs and obtain any required government approvals pertaining to use of the other Party's marks.

  • System for Award Management (XXX) Requirement Alongside a signed copy of this Agreement, Grantee will provide Florida Housing with a XXX.xxx proof of registration and Commercial and Government Entity (CAGE) number. Grantee will continue to maintain an active XXX registration with current information at all times during which it has an active award under this Agreement.