Start-Up and Synchronization Consistent with the mutually acceptable procedures of the Developer and Connecting Transmission Owner, the Developer is responsible for the proper synchronization of the Large Generating Facility to the New York State Transmission System in accordance with NYISO and Connecting Transmission Owner procedures and requirements.
System Upgrades The Connecting Transmission Owner shall procure, construct, install, and own the System Upgrade Facilities and System Deliverability Upgrades described in Attachment 6 of this Agreement. To the extent that design work is necessary in addition to that already accomplished in the Class Year Interconnection Facilities Study for the Interconnection Customer, the Connecting Transmission Owner shall perform or cause to be performed such work. If all the Parties agree, the Interconnection Customer may construct System Upgrade Facilities and System Deliverability Upgrades. 5.2.1 As described in Section 32.3.5.3 of the SGIP in Attachment Z of the ISO OATT, the responsibility of the Interconnection Customer for the cost of the System Upgrade Facilities and System Deliverability Upgrades described in Attachment 6 of this Agreement shall be determined in accordance with Attachment S of the ISO OATT, as required by Section 32.3.5.3.2
System Timeout The system providing access to PHI COUNTY discloses to 11 CONTRACTOR or CONTRACTOR creates, receives, maintains, or transmits on behalf of COUNTY 12 must provide an automatic timeout, requiring re-authentication of the user session after no more than 13 twenty (20) minutes of inactivity.
Synchronization The Licensor hereby grants limited synchronization rights for One (1) music video streamed online (Youtube, Vimeo, etc..) for up to 500,000 non-monetized video streams on all total sites. A separate synchronisation license will need to be purchased for distribution of video to Television, Film or Video game.
Supplier’s Staff 3.3.1 Access to the Premises shall be limited to such Staff and the Supplier’s suppliers as are necessary for the Supplier to fulfil its obligations under the Contract. The Supplier shall co-operate with others working on the Premises to such extent as the Authority may reasonably require. 3.3.2 The Authority reserves the right to refuse to admit to, or to withdraw permission to remain on, the Premises:- (a) for any member of the Staff; or (b) for any person employed or engaged by any member of the Staff, whose admission or continued presence would be, in the reasonable opinion of the Authority, undesirable. 3.3.3 At the Authority’s written request, the Supplier shall provide a list of the names and business addresses of all persons who may require admission in connection with the Contract to the Premises, specifying the capacities in which they are concerned with the Contract and giving such other particulars as the Authority may reasonably request. 3.3.4 The Supplier’s Staff, engaged within the boundaries of the Premises, shall comply with such rules, regulations and requirements (including those relating to security arrangements) as may be in force from time to time for the conduct of personnel when at or outside those premises. 3.3.5 If the Supplier fails to comply with Clause 3.3.3 within one (1) Month of the date of the request and in the reasonable opinion of the Authority, such failure may be prejudicial to the interests of the Crown, then the Authority may terminate the Contract, provided always that such termination shall not prejudice or affect any right of action or remedy which shall have accrued or shall thereafter accrue to the Authority. 3.3.6 The decision of the Authority as to whether any person is to be refused access to the Premises and as to whether the Supplier has failed to comply with Clause 3.3.3 shall be final and conclusive.
System Upgrade Facilities and System Deliverability Upgrades Connecting Transmission Owner shall design, procure, construct, install, and own the System Upgrade Facilities and System Deliverability Upgrades described in Appendix A hereto. The responsibility of the Developer for costs related to System Upgrade Facilities and System Deliverability Upgrades shall be determined in accordance with the provisions of Attachment S to the NYISO OATT.
System Access CUSTOMER agrees to provide to PROVIDER, at CUSTOMER’S expense, necessary access to the mainframe computer and related information technology systems (the “System”) on which CUSTOMER data is processed during the times (the “Service Hours”) specified in the PSAs, subject to reasonable downtime for utility outages, maintenance, performance difficulties and the like. In the event of a change in the Service Hours, CUSTOMER will provide PROVIDER with at least fifteen (15) calendar days written notice of such change.
System Access Control Data processing systems used to provide the Cloud Service must be prevented from being used without authorization.
XXX Hosting 10.1 XXX Hosting is not required for resale in the BellSouth region.
Commissioning Commissioning tests of the Interconnection Customer’s installed equipment shall be performed pursuant to applicable codes and standards. The ISO and Connecting Transmission Owner must be given at least five Business Days written notice, or as otherwise mutually agreed to by the Parties, of the tests and may be present to witness the commissioning tests.