Remote Connections, Extension of Gathering Facilities Sample Clauses

Remote Connections, Extension of Gathering Facilities. In the event Processor connects to Supplier’s well(s) beyond two miles from existing pipelines, then Supplier will guarantee delivery of an additional 500,000 MMBtu multiplied by the actual length in miles of each separate gathering system that is beyond two miles from existing Gathering Facilities (expressed in tenths (1/10th) of a mile) (“Additional Connect Amount”). The Supplier shall deliver to Processor the Additional Connect Amount within three years from the date of connection. In the event the full Additional Connect Amount is not provided within the allowed three years, or prior to expiration of the Agreement, Supplier agrees to pay Processor a Well Connect Fee equal to the (Additional Connect Amount less the amount actually provided toward the Additional Connect Amount at either the end of three years or as of date of expiration) multiplied by $.
AutoNDA by SimpleDocs

Related to Remote Connections, Extension of Gathering Facilities

  • Generating Facility The Interconnection Customer’s device for the production of electricity identified in the Interconnection Request, but shall not include the Interconnection Customer’s Interconnection Facilities.

  • Interconnection Facilities 4.1.1 The Interconnection Customer shall pay for the cost of the Interconnection Facilities itemized in Attachment 2 of this Agreement. The NYISO, in consultation with the Connecting Transmission Owner, shall provide a best estimate cost, including overheads, for the purchase and construction of its Interconnection Facilities and provide a detailed itemization of such costs. Costs associated with Interconnection Facilities may be shared with other entities that may benefit from such facilities by agreement of the Interconnection Customer, such other entities, the NYISO, and the Connecting Transmission Owner. 4.1.2 The Interconnection Customer shall be responsible for its share of all reasonable expenses, including overheads, associated with (1) owning, operating, maintaining, repairing, and replacing its own Interconnection Facilities, and

  • Working Facilities During the Term of Employment, the Company shall furnish the Executive with an office, secretarial help and such other facilities and services suitable to his position and adequate for the performance of his duties hereunder.

  • Verizon OSS Facilities Any gateways, interfaces, databases, facilities, equipment, software, or systems, used by Verizon to provide Verizon OSS Services to ICG.

  • Existing Facilities Each of the Existing Facilities shall be repaid in full and terminated and all collateral security therefor shall be released, and the Administrative Agent shall have received pay-off letters in form and substance satisfactory to it evidencing such repayment, termination and release.

  • Purpose of Interconnection Facilities Except as may be required by Applicable Laws and Regulations, or as otherwise agreed to among the Parties, the Interconnection Facilities shall be constructed for the sole purpose of interconnecting the Large Generating Facility to the Participating TO’s Transmission System and shall be used for no other purpose.

  • Refinancing Facilities (a) On one or more occasions after the Effective Date, the Borrower may obtain, from any Lender or any other bank, financial institution or other institutional lender or investor that agrees to provide any portion of Refinancing Term Loans pursuant to a Refinancing Amendment in accordance with this Section 2.22 (each, an “Additional Refinancing Lender”) (provided that the Administrative Agent shall have consented (such consent not to be unreasonably withheld, conditioned or delayed) to such Lender’s or Additional Refinancing Lender’s making such Refinancing Term Loans to the extent such consent, if any, would be required under Section 9.04(b) for, and to the extent that such Additional Refinancing Lender is a Purchasing Borrower Party or an Affiliated Lender, the requirements of Section 9.04(g) and 9.04(f), respectively, shall be satisfied as if such Refinancing Term Loan were, an assignment of Term Loans to such Lender or Additional Refinancing Lender), Credit Agreement Refinancing Indebtedness in respect of all or any portion of Term Loans then outstanding under this Agreement, in the form of Refinancing Term Loans or Refinancing Term Commitments pursuant to a Refinancing Amendment; provided that no Lender is obligated hereunder to provide such Credit Agreement Refinancing Indebtedness. (b) The effectiveness of any Refinancing Amendment shall be subject to the satisfaction on the date thereof of each of the conditions set forth in Section 4.02 and, to the extent reasonably requested by the Administrative Agent, receipt by the Administrative Agent of (i) customary legal opinions, board resolutions and officers’ certificates consistent with those delivered on the Effective Date other than changes to such legal opinion resulting from a change in law, change in fact or change to counsel’s form of opinion reasonably satisfactory to the Administrative Agent and (ii) reaffirmation agreements and/or such amendments to the Security Documents as may be reasonably requested by the Administrative Agent in order to ensure that such Credit Agreement Refinancing Indebtedness is provided with the benefit of the applicable Loan Documents. (c) Each issuance of Credit Agreement Refinancing Indebtedness under Section 2.22(a) shall be in an aggregate principal amount that is (x) not less than $50,000,000 and (y) an integral multiple of $10,000,000 in excess thereof. (d) Each of the parties hereto hereby agrees that this Agreement and the other Loan Documents may be amended pursuant to a Refinancing Amendment, without the consent of any other Lenders, to the extent (but only to the extent) necessary to (i) reflect the existence and terms of the Credit Agreement Refinancing Indebtedness incurred pursuant thereto and (ii) effect such other amendments to this Agreement and the other Loan Documents as may be necessary or appropriate, in the reasonable opinion of the Administrative Agent and the Borrower, to effect the provisions of this Section 2.22, including any amendments necessary to treat the applicable Loans and/or Commitments established under the Refinancing Amendment as a new Class of Loans and/or Commitments hereunder, and the Lenders hereby expressly authorize the Administrative Agent to enter into any such Refinancing Amendment. (e) This Section 2.22 shall supersede any provisions in Section 2.17 or Section 9.02 to the contrary solely to the extent provided in this Section 2.22.

  • Communications Equipment (a) Subject to the provisions of this Section 3.5, Tenant shall have the non-exclusive right, at its sole cost and expense and for Tenant’s use, to install, maintain and operate upon the roof of the Building one (1) or a reasonable and necessary additional number of transmitters and/or receiver antennas or dishes approved by Landlord, which approval shall not be unreasonably withheld or delayed (collectively, the “Communications Equipment”) for use by Tenant in the conduct of its business; provided that such Communications Equipment may not materially compromise the aesthetics or appearance of the Building nor shall Landlord be required to incur any expense in accommodating the Communications Equipment. The Communications Equipment must be (i) designed, installed and operated in compliance with all Legal Requirements, and (ii) installed and operated so as not to adversely affect or impact structural, mechanical, electrical, elevator, or other systems serving the Building or customary telephone service for the Building and so as not to cause injury to persons or property, and without limitation of the foregoing, so as not to void or impair any applicable roof warranty. Upon the expiration or termination of this Lease, Tenant shall remove the Communications Equipment and repair any damage to the Building caused by the installation, maintenance, use or removal of the Communications Equipment. (b) Landlord hereby grants to Tenant the right to install (at Tenant’s sole cost and expense) any additional equipment required to operate the Communications Equipment and to connect the Communications Equipment to Tenant’s other machinery and equipment located in the Leased Premises (e.g., conduits and cables) in the shafts, ducts, chases and utility closets located in the core of the building (“Additional Equipment”), which Additional Equipment shall be deemed a part of the Communications Equipment for all purposes of this Section 3.5; provided that (i) the use of such space in the Building core by Tenant (except customary chases for cabling) may not materially adversely affect the marketability of the remaining space on any floor of the Building, and (ii) to the extent any such Additional Equipment occupies space (other than space in customary chases for the Building) that would have otherwise been Net Rentable Area on a floor of the Building, such space shall be included within the Net Rentable Area of the Leased Premises and Tenant shall be obligated to pay Annual Basic Rent and Additional Rent with respect to such space as if such space was included in the Leased Premises. Tenant’s use of such space in the Building core shall be subject to the provisions of this Lease relating to Tenant’s use of Common Areas of the Building. (c) Subject to the Building Rules and other reasonable rules relating to Building security and safety that may be promulgated by Landlord pertaining to access by tenants to the roof of the Building and provided Tenant does not unreasonably disturb any other tenants of the Building, Tenant and Tenant’s contractors shall have reasonable access to the Communications Equipment and the Additional Equipment for purposes of operating, servicing, repairing or otherwise maintaining said equipment. (d) Nothing contained in this Section 3.5 shall be deemed to prohibit or restrict any other individual or entity, including Landlord or any other tenant of the Building, from installing communications equipment on the roof of the Building or to use the roof for any other purpose. (e) In connection with its installation, repair, maintenance and removal of any Communications Equipment and Additional Equipment, Tenant, at Tenant’s sole cost and expense, shall comply with all applicable Building Rules and Legal Requirements and repair any damage to the Building caused by such installation, repair, maintenance or removal. In the event that the placement of Tenant’s Communications Equipment or Additional Equipment interferes with Landlord’s performance of any repair or maintenance to the Common Areas, including the roofs of the Buildings, any costs incurred by Landlord to temporarily or permanently relocate and reinstall Tenant’s Communications Equipment or Additional Equipment shall be included in the cost of such repair or maintenance as a Operating Expense. (f) Tenant’s Communications Equipment and Additional Equipment existing as of the Commencement Date are hereby deemed to be approved by Landlord. Any changes to the existing Communications Equipment and/or Additional Equipment by Tenant shall first be approved by Landlord, which approval will not be unreasonably withheld or delayed. (g) If Landlord shall place on the roof of any Building communications equipment of its own, or shall grant to any third party the right to locate and maintain any such equipment, all such equipment shall be located, designed and operated so as not to interfere with signals to and from Tenant’s Communications Equipment and Additional Equipment, the installation of which, in accordance with this Section 3.5, predates the installation of such other equipment. Similarly, any Communications Equipment and Additional Equipment hereafter installed by Tenant shall be located and designed so as not to interfere with signals to and from such other equipment belonging to Landlord or to third parties, that may have previously been installed. The party responsible for the communications equipment which interferes with equipment previously installed by others shall be required, at its or their expense, to take all measures necessary to eliminate the source of interference caused by such party’s equipment.

  • Participating TO’s Interconnection Facilities The Participating TO shall design, procure, construct, install, own and/or control the Participating TO’s Interconnection Facilities described in Appendix A at the sole expense of the Interconnection Customer. Unless the Participating TO elects to fund the capital for the Participating TO’s Interconnection Facilities, they shall be solely funded by the Interconnection Customer.

  • NYISO and Connecting Transmission Owner Obligations Connecting Transmission Owner and NYISO shall cause the New York State Transmission System and the Connecting Transmission Owner’s Attachment Facilities to be operated, maintained and controlled in a safe and reliable manner in accordance with this Agreement and the NYISO Tariffs. Connecting Transmission Owner and NYISO may provide operating instructions to Developer consistent with this Agreement, NYISO procedures and Connecting Transmission Owner’s operating protocols and procedures as they may change from time to time. Connecting Transmission Owner and NYISO will consider changes to their respective operating protocols and procedures proposed by Developer.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!