ODUF Physical File Characteristics 6.2.1 ODUF will be distributed to TWTC via Secure File Transfer Protocol (FTP). The ODUF feed will be a variable block format. The data on the ODUF feed will be in a non-compacted EMI format (175 byte format plus modules). It will be created on a daily basis Monday through Friday except holidays. Details such as dataset name and delivery schedule will be addressed during negotiations of the distribution medium. There will be a maximum of one dataset per workday per OCN. If AT&T determines the Secure FTP Mailbox is nearing capacity levels, AT&T may move the customer to CONNECT: Direct file delivery. 6.2.2 If the customer is moved, CONNECT: Direct data circuits (private line or dial-up) will be required between AT&T and TWTC for the purpose of data transmission. Where a dedicated line is required, TWTC will be responsible for ordering the circuit, overseeing its installation and coordinating the installation with AT&T. TWTC will also be responsible for any charges associated with this line. Equipment required on the AT&T end to attach the line to the mainframe computer and to transmit messages successfully on an ongoing basis will be negotiated on an individual case basis. Any costs incurred for such equipment will be TWTC's responsibility. Where a dial-up facility is required, dial circuits will be installed in the AT&T data center by AT&T and the associated charges assessed to TWTC. Additionally, all message toll charges associated with the use of the dial circuit by TWTC will be the responsibility of TWTC. Associated equipment on the AT&T end, including a modem, will be negotiated on an individual case basis between the Parties. All equipment, including modems and software, that is required on TWTC end for the purpose of data transmission will be the responsibility of TWTC. 6.2.3 If TWTC utilizes FTP for data file transmission, purchase of the FTP software will be the responsibility of TWTC.
Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Xxxx has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Xxxx. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Xxxx (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Xxxx, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Xxxx will then have the option of paying the one-time SC rates to place the Loop.
Client Classification 7.1. We shall not have an obligation to treat our clients in different classes depending on their knowledge and expertise.
Product Changes Vocera shall have the right, in its absolute discretion, without liability to End User, to update to provide new functionality or otherwise change the design of any Product or to discontinue the manufacture or sale of any Product. Vocera shall notify End User at least 90 days prior to the delivery of any Product which incorporates a change that adversely affects form, fit or function (“Material Change”). Vocera shall also notify End User at least 90 days prior to the discontinuance of manufacture of any Product. Notification will be made as soon as reasonably practical for changes associated with regulatory or health and safety issues.
Classification of Goods The classification of goods in trade between the Parties shall be in conformity with the Harmonized System.
Original Material The description of the material being transferred will be specified in an implementing letter.
New Job Classifications When a new classification (which is covered by the terms of this collective agreement) is established by the Hospital, the Hospital shall determine the rate of pay for such new classification and notify the local Union of the same. If the local Union challenges the rate, it shall have the right to request a meeting with the Hospital to endeavour to negotiate a mutually satisfactory rate. Such request will be made within ten (10) days after the receipt of notice from the Hospital of such new occupational classification and rate. Any change mutually agreed to resulting from such meeting shall be retroactive to the date that notice of the new rate was given by the Hospital. If the parties are unable to agree, the dispute concerning the new rate may be submitted to arbitration as provided in the agreement within fifteen (15) days of such meeting. The decision of the arbitrator (or board of arbitration as the case may be) shall be based on the relationship established by comparison with the rates for other classifications in the bargaining unit having regard to the requirements of such classification. When the Hospital makes a substantial change in the job content of an existing classification which in reality causes such classification to become a new classification, the Hospital agrees to meet with the Union if requested to permit the Union to make representation with respect to the appropriate rate of pay. If the matter is not resolved following the meeting with the Union, the matter may be referred to arbitration as provided in the agreement within fifteen (15) days of such meeting. The decision of the arbitrator (or board of arbitration as the case may be) shall be based on the relationship established by comparison with the rates for other classifications in the bargaining unit having regard to the requirements of such classifications. The parties further agree that any change mutually agreed to or awarded as a result of arbitration shall be retroactive only to the date that the Union raised the issue with the Hospital. The parties further agree that the above process as provided herein shall constitute the process for Pay Equity Maintenance as required by the Pay Equity Act.
Promotional Material In the event that the Fund or the Investment Adviser makes available any promotional materials related to the Securities or the transactions contemplated hereby intended for use only by registered broker-dealers and registered representatives thereof by means of an Internet web site or similar electronic means, the Investment Adviser will install and maintain or will cause to be installed and maintained, pre-qualification and password-protection or similar procedures which are reasonably designed to effectively prohibit access to such promotional materials by persons other than registered broker-dealers and registered representatives thereof.
Classification Structure All employees working under this Agreement shall be classified according to the skill based classification structure set out in Appendix A.
Physical File Characteristics 7.2.1 The EODUF feed will be distributed to Comcast Phone over their existing Optional Daily Usage File (ODUF) feed. The EODUF messages will be intermingled among Comcast Phone’s Optional Daily Usage File (ODUF) messages. The EODUF will be a variable block format (2476) with an LRECL of 2472. The data on the EODUF will be in a non-compacted EMI format (175 byte format plus modules). It will be created on a daily basis (Monday through Friday except holidays). 7.2.2 Data circuits (private line or dial-up) may be required between BellSouth and Comcast Phone for the purpose of data transmission. Where a dedicated line is required, Comcast Phone will be responsible for ordering the circuit, overseeing its installation and coordinating the installation with BellSouth. Comcast Phone will also be responsible for any charges associated with this line. Equipment required on the BellSouth end to attach the line to the mainframe computer and to transmit successfully ongoing will be negotiated on an individual case basis. Where a dial-up facility is required, dial circuits will be installed in the BellSouth data center by BellSouth and the associated charges assessed to Comcast Phone. Additionally, all message toll charges associated with the use of the dial circuit by Comcast Phone will be the responsibility of Comcast Phone. Associated equipment on the BellSouth end, including a modem, will be negotiated on an individual case basis between the Parties. Version 4Q01 12/01/01 All equipment, including modems and software, that is required on Comcast Phone’s end for the purpose of data transmission will be the responsibility of Comcast Phone.