Secondary Reached Overload Triggers When Sample Clauses

Secondary Reached Overload Triggers When a class size or total student load in grades 6-12 has reached its overload trigger and maintained that level for eight (8) continuous school days, the teacher shall receive two dollars ($2.00) per student per class period or student load at the overload trigger with payment retroactive to the first day the overload trigger was reached; provided, however, that a student tutor or a student assistant will not count as part of the class size. Payment shall continue as long as the class or student load is at its overload trigger.
AutoNDA by SimpleDocs

Related to Secondary Reached Overload Triggers When

  • Substantial Completion Date Substantial Completion of the Work as defined in Article 6.1.2 of the General Conditions to the Continuing Contract for Construction Management shall be achieved by July 31, 2022.

  • Follow-up Testing An employee shall submit to unscheduled follow-up drug and/or alcohol testing if, within the previous 24-month period, the employee voluntarily disclosed drug or alcohol problems, entered into or completed a rehabilitation program for drug or alcohol abuse, failed or refused a preappointment drug test, or was disciplined for violating the provisions of this Agreement and Employer work rules. The Employer may require an employee who is subject to follow-up testing to submit to no more than six unscheduled drug or alcohol tests within any 12 month period.

  • EVENTS OUTSIDE OUR CONTROL 10.1 We will not be liable or responsible for any failure to perform, or delay in performance of, any of our obligations under this XXXX that is caused by any act or event beyond our reasonable control, including failure of public or private telecommunications networks (Event Outside Our Control). 10.2 If an Event Outside Our Control takes place that affects the performance of our obligations under this XXXX: (a) our obligations under this XXXX will be suspended and the time for performance of our obligations will be extended for the duration of the Event Outside Our Control; and (b) we will use our reasonable endeavours to find a solution by which our obligations under this XXXX may be performed despite the Event Outside Our Control.

  • Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Xxxx has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Xxxx. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Xxxx (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Xxxx, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Xxxx will then have the option of paying the one-time SC rates to place the Loop.

  • Project Completion Date It is agreed between the Parties that the Project Completion Date is <END DATE, YEAR>. If the Project is not completed by such date then, subject to an amendment agreed to between the Parties, Alberta Innovates may elect to terminate this Investment Agreement. In such event, Alberta Innovates will notify the Applicant of its decision to terminate as soon as reasonably practical and shall advise the Applicant of the effective date of termination. Alberta Innovates will have no liability or obligation to reimburse the Applicant for any Project Costs incurred after the effective date of termination and may require the Applicant to return any portions of the Investment which were spent on Ineligible Expenses. Additionally, any portion of the Investment not used and accounted for in accordance with this Agreement as of the Project Completion Date or earlier termination is repayable by the Applicant to AI at AI’s request.

  • Tandem Transit Traffic ‌ 12.1 As used in this Section, Tandem Transit Traffic is Telephone Exchange Service traffic that originates on Onvoy's network, and is transported through Frontier’s Tandem to the subtending End Office or its equivalent of another carrier (CLEC, ILEC other than Frontier, Commercial Mobile Radio Service (CMRS) carrier, or other LEC (“Other Carrier”). Neither the originating nor terminating customer is a Customer of Frontier. Subtending End Offices shall be determined in accordance with and as identified in the Local Exchange Routing Guide (LERG). For the avoidance of any doubt, under no circumstances shall Frontier be required to transit traffic through a Frontier Tandem to a Central Office that the LERG does not identify as subtending that particular Frontier Tandem. Switched Exchange Access Service traffic is not Tandem Transit Traffic. 12.2 Tandem Transit Traffic Service provides Onvoy with the transport of Tandem Transit Traffic as provided below. 12.3 Tandem Transit Traffic may be routed over the Interconnection Trunks described in Sections 2 through 6 of this Attachment. Onvoy shall deliver each Tandem Transit Traffic call to Frontier’s Tandem with CCS and the appropriate Transactional Capabilities Application Part (“TCAP”) message to facilitate full interoperability of CLASS Features and billing functions. 12.4 Onvoy may use Tandem Transit Traffic Service only for traffic that originates on Onvoy’s network and only to send traffic to an Other Carrier with whom Onvoy has a reciprocal traffic exchange arrangement (either via written agreement or mutual tariffs) that provides for the Other Carrier, to terminate or complete traffic originated by Onvoy and to bill Onvoy, and not to bill Frontier, for such traffic. Onvoy agrees not to use Frontier’s Tandem Transit Traffic Service to send traffic to an Other Carrier with whom Onvoy does not have such a reciprocal traffic exchange arrangement or to send traffic that does not originate on Onvoy’s network. 12.5 Onvoy shall pay Frontier for Tandem Transit Traffic Service at the rates specified in the Pricing Attachment. Frontier will not be liable for compensation to any Other Carrier for any traffic that is transported through Frontier’s Tandem and Frontier reserves the right to assess to Onvoy any additional charges or costs any Other Carrier imposes or levies on Frontier for the delivery or termination of such traffic, including any Switched Exchange Access Service charges. If Frontier is billed by any Other Carrier for any traffic originated by Onvoy, Frontier may provide notice to Onvoy of such billing. Upon receipt of such notice, Onvoy shall immediately stop using Frontier’s Tandem Transit Traffic Service to send any traffic to such Other Carrier until it has provided to Frontier certification that the Other Carrier has removed such billed charges from its bill to Frontier and that the Other Carrier will not bill Frontier for any traffic originated by Onvoy. Such certification must be signed by an authorized officer or agent of the Other Carrier and must be in a form acceptable to Frontier. 12.6 If Onvoy uses Tandem Transit Traffic Service for traffic volumes that exceed the Centum Call Seconds (Hundred Call Seconds) busy hour equivalent of 200,000 combined minutes of use per month (a DS1 equivalent) to the subtending End Office of a particular Other Carrier for any month (the “Threshold Level”). Onvoy shall use good faith efforts to establish direct interconnection with such Other Carrier and reduce such traffic volumes below the Threshold Level. If Frontier believes that Xxxxx has not exercised good faith efforts promptly to obtain such direct interconnection, either Party may use the Dispute Resolution processes of this Agreement. 12.7 If Onvoy fails to comply with Section 12 of this Attachment, such failure shall be a material breach of a material provision of this Agreement and Frontier may exercise any and all remedies under this Agreement and Applicable Law for such breach. 12.8 If or when a third party carrier plans to subtend an Onvoy switch, then Onvoy shall provide written notice to Frontier at least ninety (90) days before such subtending service arrangement becomes effective so that Frontier may negotiate and establish direct interconnection with such third party carrier. Upon written request from Frontier, Onvoy shall offer to Frontier a service arrangement equivalent to or the same as Tandem Transit Traffic Service provided by Frontier to Onvoy as defined in this Section such that Frontier may terminate calls to a Central Office or its equivalent of a CLEC, ILEC other than Frontier, CMRS carrier, or other LEC, that subtends an Onvoy Central Office or its equivalent (“Reciprocal Tandem Transit Service”). Onvoy shall offer such Reciprocal Transit Service arrangements under terms and conditions of an amendment to this Agreement or a separate agreement no less favorable than those provided in this Section. 12.9 Neither Party shall take any actions to prevent the other Party from entering into a direct and reciprocal traffic exchange arrangement with any carrier to which it originates, or from which it terminates, traffic.

  • Local Circuit Switching Capability, including Tandem Switching Capability 4.1.3.1 Definition 4.1.3.2 Notwithstanding BellSouth’s general duty to unbundle local circuit switching, BellSouth shall not be required to unbundle local circuit switching for <<customer_name>> when <<customer_name>> serves end-users with four (4) or more voice-grade (DS-0) equivalents or lines in locations served by BellSouth’s local circuit switches, which are in the following MSAs: Atlanta, GA; Miami, FL; Orlando, FL; Ft. Lauderdale, FL; Charlotte-Gastonia-Rock Hill, NC; Greensboro-Winston Salem-High Point, NC; Nashville, TN; and New Orleans, LA, and BellSouth has provided non-discriminatory cost based access to the Enhanced Extended Link (EEL) throughout Density Zone 1 as determined by NECA Tariff No. 4 as in effect on January 1, 1999. 4.1.3.3 In the event that <<customer_name>> orders local circuit switching for a single end user account name at a single physical end user location with four (4) or more 2-wire voice-grade loops from a BellSouth central office in an MSA listed above, BellSouth shall charge <<customer_name>> the market based rate in Exhibit C for use of the local circuit switching functionality for the affected facilities. 4.1.3.4 A featureless port is one that has a line port, switching facilities, and an interoffice port. A featured port is a port that includes all features then capable or a number of then capable features specifically requested by <<customer_name>>. Any features that are not currently then capable but are technically feasible through the switch can be requested through the NBR/BFR process. 4.1.3.5 BellSouth will provide to <<customer_name>> customized routing of calls: (i) to a requested directory assistance services platform; (ii) to an operator services platform pursuant to Section 10 of Attachment 2; (iii) for <<customer_name>>’s PIC’ed toll traffic in a two (2) PIC environment to an alternative OS/DA platform designated by <<customer_name>>. <<customer_name>> customers may use the same dialing arrangements as BellSouth customers. 4.1.3.6 Remote Switching Module functionality is included in Switching Capability. The switching capabilities used will be based on the line side features they support. 4.1.3.7 Switching Capability will also be capable of routing local, intraLATA, interLATA, and calls to international customer’s preferred carrier; call features (e.g. call forwarding) and Centrex capabilities. 4.1.3.8 Where required to do so in order to comply with an effective Commission order, BellSouth will provide to <<customer_name>> purchasing local BellSouth switching and reselling BellSouth local exchange service under Attachment 1, selective routing of calls to a requested directory assistance services platform or operator services platform. <<customer_name>> customers may use the same dialing arrangements as BellSouth customers, but obtain a <<customer_name>> branded service.

  • Default under Specified Transaction The party, any Credit Support Provider of such party or any applicable Specified Entity of such party (1) defaults under a Specified Transaction and, after giving effect to any applicable notice requirement or grace period, there occurs a liquidation of, an acceleration of obligations under, or an early termination of, that Specified Transaction, (2) defaults, after giving effect to any applicable notice requirement or grace period, in making any payment or delivery due on the last payment, delivery or exchange date of, or any payment on early termination of, a Specified Transaction (or such default continues for at least three Local Business Days if there is no applicable notice requirement or grace period) or (3) disaffirms, disclaims, repudiates or rejects, in whole or in part, a Specified Transaction (or such action is taken by any person or entity appointed or empowered to operate it or act on its behalf);

  • Power Factor Design Criteria (Reactive Power A wind generating plant shall maintain a power factor within the range of 0.95 leading to 0.95 lagging, measured at the Point of Interconnection as defined in this LGIA, if the ISO’s System Reliability Impact Study shows that such a requirement is necessary to ensure safety or reliability. The power factor range standards can be met using, for example without limitation, power electronics designed to supply this level of reactive capability (taking into account any limitations due to voltage level, real power output, etc.) or fixed and switched capacitors if agreed to by the Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected, or a combination of the two. The Developer shall not disable power factor equipment while the wind plant is in operation. Wind plants shall also be able to provide sufficient dynamic voltage support in lieu of the power system stabilizer and automatic voltage regulation at the generator excitation system if the System Reliability Impact Study shows this to be required for system safety or reliability.

  • Construction Period During the construction period, Redeveloper agrees to keep the construction area, including completed operations insured against loss or damage by fire, and such other risks, casualties, and hazards as are customarily covered by builders’ risk or extended coverage policies in an amount not less than the replacement value but allowing for reasonable coinsurance clauses and deductibles. In the event of any insured damage or destruction, Redeveloper agrees to use its good faith efforts to commence restoration of the Private Improvements to its prior condition within nine (9) months from the date of the damage or destruction, and shall diligently pursue the same to completion.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!