Title Block Requirements Sample Clauses

Title Block Requirements. Title Block Attributes for Layout Views Compulsory The Project or Development Name. Yes Stage Number (if applicable) Yes Legal Property Description Yes The works approval ID for the development this information represents (D/A number) Yes Drawing Number No Date the drawing was revised Yes As Constructed' Stamp Yes Name of Principle Contractor Yes Horizontal & Vertical Datum used Yes Name & Signature of Registered Professional Engineer Yes RPEQ Number & Date Yes Table 2: AutoCAD Requirements General Information: Requirements: AutoCAD Version Version 2000 or later. Title Block Provide a title block on each of the layout pages: includes the contract number and revision number; an ‘As Constructed’ stamp including the name of the principal contractor & RPEQ number and date and the horizontal and vertical datum used. Survey Station & Reference Points. Provide the survey station and reference marks xyz values to assist positional accuracy verification. Dimension Planes 2 Datum/Projection The Map Grid Australia (MGA94) Cartesian coordinate system: GDA94 UTM Zones (generally Zone 56 within Council’s region) Eastings and Northings Drawing Units Metres Drawing Precision 6 Decimal places No. of Annotated Decimal Places 3 Text File Format ASCII Polyline map objects For radial bends (e.g. roads and xxxxx in cul-de-sacs) a pickup point is required at every expansion point. Points Scaling Relative Civil 3D points Convert to AutoCAD points Table 3: Drawn Object Tolerances & DWG Layer Names Asset Category Asset Type Displayed Location (Plan View) Positional Accuracy (XY) (90% confidence limit) (± x mm) * Vertical Accuracy (Z) (90% confidence limit) (± x mm) Object Type (Submitted drawing format specification) DWG Required Layer Name Transport Kerb/ Kerb & Channel Lip of Kerb/Kerb and channel; segments must apply to only 1 road; segmented showing consistent construction/attributes and ignoring kerb inlets & driveways. ±50mm ±10mm Continuous Polyline ROAD_KERB Concrete Invert Invert of drain. Line work to be drawn in the direction of flow. ±80mm ±10mm Continuous Polyline ROAD_KERB Roads (sealed): Roads (unsealed): Road Sealed - Segmented showing consistent pavement/ surface construction & attribute information incl. separate roundabouts. Road Unsealed - Provide the edge of shoulder/edge of carraigeway, segmented showing consistent pavement construction. ±80mm NA Closed Polyline ROAD_EB_PAVEMENT Parking Areas Segmented showing consistent pavement/ surface construction & attrib...
AutoNDA by SimpleDocs
Title Block Requirements. − Electronic drawing files must contain only one drawing and one title block per file. − Title block information must include the following information: o A/E/C – consultant responsible for producing the drawings should be clearly identified.

Related to Title Block Requirements

  • TITLE VI REQUIREMENTS H-GAC in accordance with the provisions of Title VI of the Civil Rights Act of 1964 (78 Xxxx. 000, 00 X.X.X. §§ 0000x to 2000d-4) and the Regulations, hereby notifies all bidders that it will affirmatively ensure that any disadvantaged business enterprises will be afforded full and fair opportunity to submit in response to this Agreement and will not be discriminated against on the grounds of race, color, or national origin in consideration for an award.

  • Check Requirements Any image of a check that I transmit to you must accurately and legibly provide all the information on the front and back of the check at the time presented to me by the drawer. Prior to capturing the original check, I will indorse the back of the original check. My endorsement will include "For Directions E- Deposit Only" in addition to my signature. The image of the check transmitted to you must accurately and legibly provide, among other things, the following information: (1) the information identifying the drawer and the paying bank that is preprinted on the check, including complete and accurate MICR information and the signature(s); and (2) other information placed on the check prior to the time an image of the check is captured, such as any required identification written on the front of the check and any endorsements applied to the back of the check. The image quality for the check will meet the standards for image quality established by the American National Standards Institute ("ANSI"), the Board of Governors of the Federal Reserve, and any other regulatory agency, clearing house or association. Rejection of Deposit. You are not liable for any service or late charges levied against me due to your rejection of any item. In all cases, I am responsible for any loss or overdraft plus any applicable fees to my Account due to an item being returned. Items Returned Unpaid. A written notice will be sent to me of transactions you are unable to process because of returned items. With respect to any item that I transmit to you for remote deposit that you credit to my Account, in the event such item is dishonored, I authorize you to debit the amount of such item from the Account. Email Address. I agree to notify you immediately if I change my email address, as this is the email address where you will send me notification of receipt of remote deposit items.

  • Test requirements 3.1. The limits apply throughout the frequency range 30 to 1,000 MHz for measurements performed in a semi anechoic chamber or an outdoor test site.

  • Project Requirements Failure to comply with the following requirements will result in a suspension of all other operations:

  • Management Requirements Procedures for managing equipment (including replacement equipment), whether acquired in whole or in part under a Federal award, until disposition takes place will, as a minimum, meet the following requirements:

  • DATA ESCROW REQUIREMENTS Registry Operator will engage an independent entity to act as data escrow agent (“Escrow Agent”) for the provision of data escrow services related to the Registry Agreement. The following Technical Specifications set forth in Part A, and Legal Requirements set forth in Part B, will be included in any data escrow agreement between Registry Operator and the Escrow Agent, under which ICANN must be named a third-­‐party beneficiary. In addition to the following requirements, the data escrow agreement may contain other provisions that are not contradictory or intended to subvert the required terms provided below.

  • Divestment Requirements 34.1.1 Upon Termination, the Concessionaire shall comply with and conform to the following Divestment Requirements:

  • HIPAA Requirements The Parties agree that the provisions under HIPAA Rules that are required by law to be incorporated into this Amendment are hereby incorporated into this Agreement.

  • Schedule Requirements The Contractor shall submit an electronic and a paper copy of the initial Work Progress Schedule reflecting accurate and reliable representations of the planned progress of the Work, the Work to date if any, and of the Contractor’s actual plans for its completion. The Contractor shall organize and provide adequate detail so the Work Progress Schedule is capable of measuring and forecasting the effect of delaying events on completed and uncompleted activities.

  • Bonding Requirements The Contractor is required to furnish a performance bond on the form in a form acceptable to the City, in a sum of not less than [insert bonding level] of the annual amount of the contract to guarantee the faithful performance of this contract. The bond must be approved as to sufficiency and qualifications of the surety by the Controller.

Time is Money Join Law Insider Premium to draft better contracts faster.