Upgrading Line Protection Systems at Xxxxxx Xxxx 345kV Sample Clauses

Upgrading Line Protection Systems at Xxxxxx Xxxx 345kV. The Transmission Developer will upgrade the existing Xxxxxx Road-NGRID Five Mile (Line 29) line protection systems at the 000 xX Xxxxxx Road Substation. This work will include the following major protection and control equipment at the Xxxxxx to East Xxxxxx line terminal: • Replace existing system A line relay (SEL-421) with one (1) SEL-411L system A line protection relay utilizing a line differential protection scheme; • Replace existing system B line relay (Siemens SIPROTEC) with one (1) GE-L90 system 2 line protection relay utilizing a line differential protection scheme; • Twelve (12) FT-1 test switches; • Remove existing line trap and line tuner; • Remove existing System A RFL 9785 and RFL 9780 powerline carrier system devices; • Remove existing System B RFL GARD 8000 device and disconnect the existing System B relay communications (JMUX over leased line); • Install two (2) distinct fiber optic cables for the new line differential protection between Xxxxxx Xx and East Xxxxxx Xx; • Optical ground wire (“OPGW”) will be used for system A and all-dielectric self- supporting (“ADSS”) routed underground will be used for system B; and • Install two (2) fiber patch panels to terminate the two distinct fiber cables required for the new System A and System B relaying.
AutoNDA by SimpleDocs

Related to Upgrading Line Protection Systems at Xxxxxx Xxxx 345kV

  • System Upgrade Facilities and System Deliverability Upgrades Connecting Transmission Owner shall design, procure, construct, install, and own the System Upgrade Facilities and System Deliverability Upgrades described in Appendix A hereto. The responsibility of the Developer for costs related to System Upgrade Facilities and System Deliverability Upgrades shall be determined in accordance with the provisions of Attachment S to the NYISO OATT.

  • XXX Hosting 10.1 XXX Hosting is not required for resale in the BellSouth region.

  • Originating Switched Access Detail Usage Data A category 1101XX record as defined in the EMI Telcordia Practice BR-010-200- 010.

  • Sxxxxxxx-Xxxxx Compliance As soon as it is legally required to do so, the Company shall take all actions necessary to obtain and thereafter maintain material compliance with each applicable provision of the Sxxxxxxx-Xxxxx Act of 2002 and the rules and regulations promulgated thereunder and related or similar rules and regulations promulgated by any other governmental or self-regulatory entity or agency with jurisdiction over the Company.

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at a P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Trunk Group Architecture and Traffic Routing 5.2.1 The Parties shall jointly establish Access Toll Connecting Trunks between CLEC and CBT by which they will jointly provide Tandem-transported Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic from and to CLEC's Customers. 5.2.2 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access and non-translated Toll Free traffic (e.g., 800/888) to allow CLEC’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier that is connected to the CBT access Tandem. 5.2.3 The Access Toll Connecting Trunks shall be one-way or two-way trunks, as mutually agreed, connecting an End Office Switch that CLEC utilizes to provide Telephone Exchange Service and Switched Exchange Access Service in the given LATA to an access Tandem Switch CBT utilizes to provide Exchange Access in the LATA.

  • Proposed Policies and Procedures Regarding New Online Content and Functionality By October 31, 2017, the School will submit to OCR for its review and approval proposed policies and procedures (“the Plan for New Content”) to ensure that all new, newly-added, or modified online content and functionality will be accessible to people with disabilities as measured by conformance to the Benchmarks for Measuring Accessibility set forth above, except where doing so would impose a fundamental alteration or undue burden. a) When fundamental alteration or undue burden defenses apply, the Plan for New Content will require the School to provide equally effective alternative access. The Plan for New Content will require the School, in providing equally effective alternate access, to take any actions that do not result in a fundamental alteration or undue financial and administrative burdens, but nevertheless ensure that, to the maximum extent possible, individuals with disabilities receive the same benefits or services as their nondisabled peers. To provide equally effective alternate access, alternates are not required to produce the identical result or level of achievement for persons with and without disabilities, but must afford persons with disabilities equal opportunity to obtain the same result, to gain the same benefit, or to reach the same level of achievement, in the most integrated setting appropriate to the person’s needs. b) The Plan for New Content must include sufficient quality assurance procedures, backed by adequate personnel and financial resources, for full implementation. This provision also applies to the School’s online content and functionality developed by, maintained by, or offered through a third-party vendor or by using open sources. c) Within thirty (30) days of receiving OCR’s approval of the Plan for New Content, the School will officially adopt, and fully implement the amended policies and procedures.

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

  • Xxxxxxxx-Xxxxx Compliance As soon as it is legally required to do so, the Company shall take all actions necessary to obtain and thereafter maintain material compliance with each applicable provision of the Xxxxxxxx-Xxxxx Act of 2002 and the rules and regulations promulgated thereunder and related or similar rules and regulations promulgated by any other governmental or self-regulatory entity or agency with jurisdiction over the Company.

  • Network Access TENANT may find it necessary to purchase a network interface card, wireless PC card or other hardware in order to connect to the internet service. LANDLORD is not responsible for the purchase of these items and LANDLORD cannot guarantee compatibility with any device TENANT may have. The computer and network card must have software installed that supports the Internet Protocol commonly referred to as TCP/IP. Any conflicts between the software compatibility of the network and the TENANT’S computer operating system or any other feature will be the responsibility of the TENANT to resolve. LANDLORD will not be responsible for software issues related to the user’s personal computer.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!