We use cookies on our site to analyze traffic, enhance your experience, and provide you with tailored content.

For more information visit our privacy policy.

Ntop definition

Ntop. This is an integrated tool that can do various kinds of measurements and types of analysis on IP traffic. The four main functions of Ntop are traffic measurement, traffic monitoring, network optimization and planning, and detection of network security violations. Ntop is available as an open source package [44]. The tool can capture and analyze traffic separately from various hosts in a broadcast environment [41]. • MIB-II: The IETF defined the MIB-II [45] as a MIB that all compliant devices should implement and in fact has been deployed by the majority of IP capable equipment. Many IP related metrics can be derived by measurements taken from MIB-II. • Remote Monitoring (RMON): This standard is defined by IETF and enables the monitoring of complete network segments consisting of multiple hosts. RMON currently exists in two versions (RMON-1, and RMON-2) which are described in a set of four documents [46, 47, 48, 49]. RMON-1 can only be used to monitor networks at the Ethernet layer, whereas RMON-2 adds capabilities to RMON to also monitor layers 3 up to 7 of the OSI model. RMON can be used to determine spurious packet rates, error ratios and loss ratios within a single broadcast domain along with throughput verification but it cannot measure transfer delay or variations in transfer delays [41]. • Multi Router Traffic Grapher (MRTG): This tool can monitor sent and received traffic along with occurred errors at router interfaces, and present the results in a graphical form on a web page. The information that MRTG provides can be used as an indication for the values of the throughput and error ratio [41].

Examples of Ntop in a sentence

  • Finally, in the renumbered network, azenar and aria monitor each other, and of course are both renumbered.We deployed the same management/supervision applications on luffy, aria and azenar, which are NetSNMP, Ntop, MRTG and Nagios.The renumbered hosts are configured to use Stateless Address Autoconfiguration (SLAAC) for practical purposes, instead of DHCPv6.

  • The spread in the trends induced by errors in measurements and infilling has a standard deviation of 0.028 Wm−2, compara- ble to the uncertainty due to internal variability when the upper ocean is fully sampled, but smaller than the uncertainty due to internal variability when only the Argo region is sampled within CESM1.

  • The license partner can download the original electronic invoice from the ARA online portal.

  • When the network is renumbered, if the monitoring station uses a dual stack network IPv4 and IPv6, even if the IPv6 address used by Ntop isn't updated according to the new address, the stats are still updated (for both IPv4 and IPv6).We used the same script to resolve the problems, and then it worked perfectly.

  • Ntop isn't concerned, because there isn't any such configuration for this tool.Using LLA with NetSNMP works fine, SET and GET operations succeed, before, during and after a network renumbering.

  • We don't know yet if this will be done by writing a script or modifying Ntop itself.Then, we are aiming at providing, either a dependence MIB or a daemon running on the managed hosts and which would alert the management station if something went wrong.

  • We also have to take a look at the problem from the software developer's point of view, and try to provide some hints on how these could evolve in order to avoid some of the problems we highlighted earlier.Once these are done, the first thing we would like to take care of is the data continuity for Ntop.

  • The original version of Ntop [2] and argus [10] are good examples of the single system architecture, which may still be deployed on under-utilized and low-speed network links.

  • If the firewall is Unix-based, Ntop (see below) can give very good graphical statistics of network usage.Netflow is a feature of Cisco routers that collects network data.

  • The information about the captured packets is then used to perform the four main Ntop functions.

Related to Ntop

  • Storage area means any location, facility, or vehicle which is used to store, to transport, or to secure a radiographic exposure device, a storage container, or a sealed source when it is not in use and which is locked or has a physical barrier to prevent accidental exposure, tampering with, or unauthorized removal of the device, container, or source.

  • Water Surface Elevation (WSE means the height, in relation to NAVD 1988, of floods of various magnitudes and frequencies in the floodplains of riverine areas.

  • Demarcation Point The Demarcation Point shall have the meaning set forth in 47 Digital Subscriber Line Access Multiplexer (DSLAM): Equipment that links End User xDSL connections to a single packet switch, typically ATM or IP. Direct Trunked Transport (DTT): A DS1 or DS3 interoffice facility that connects the CenturyLink Serving Wire Center of the CLEC’s Local Interconnection Entrance Facility or Collocation to the terminating CenturyLink Tandem or End Office used exclusively for the transmission and routing of Telephone Exchange Service and Exchange Access.

  • CONE Area means the areas listed in Tariff, Attachment DD, section 5.10(a)(iv)(A) and any LDAs established as CONE Areas pursuant to Tariff, Attachment DD, section 5.10(a)(iv)(B).

  • L.S.D. means lysergic acid diethylamide.

  • Opium poppy means the plant of the species Papaver somniferum L., except the seeds thereof.

  • Uppermost aquifer means the geologic formation nearest the natural ground surface that is an aquifer, as well as lower aquifers that are hydraulically interconnected with this aquifer within the facility's property boundary.

  • Water surface elevation means the height, in relation to the National Geodetic Vertical Datum (NGVD) of 1929, the North American Vertical Datum (NAVD) of 1988, or other datum, where specified, of floods of various magnitudes and frequencies in the floodplains of riverine areas.

  • Built-Up Area and/or “Covered Area” in relation to a Flat shall mean the floor area of that Flat including the area of balconies and terraces, if any attached thereto, and also the thickness of the walls (external or internal) and the columns and pillars therein Provided That if any wall, column or pillar be common between two Flats, then one-half of the area under such wall column or pillar shall be included in the built-up area of each such Flat.

  • Gross Station Heat Rate or ‘GHR’ means the heat energy input in kCal required to generate one kWh of electrical energy at generator terminals of a thermal generating station;

  • Loop Concentrator/Multiplexer or "LCM" is the Network Element that does one or more of the following: aggregates lower bit rate or bandwidth signals to higher bit rate or bandwidth signals (multiplexing); disaggregates higher bit rate or bandwidth signals to lower bit rate or bandwidth signals (demultiplexing); aggregates a specified number of signals or channels to fewer channels (concentrating); performs signal conversion, including encoding of signals (e.g., analog to digital and digital to analog signal conversion); or in some instances performs electrical to optical (E/O) conversion. LCM includes DLC, and D4 channel banks and may be located in Remote Terminals or Central Offices.

  • stacked bicycle parking space means a horizontal bicycle parking space that is positioned above or below another bicycle parking space and equipped with a mechanical device providing floor level access to both bicycle parking spaces.

  • Basal area means the effective surface area available to transmit the treated effluent from the filter media in a mound system into the in-situ receiving soils. The perimeter is measured at the interface of the imported fill material and in-situ soil. On sloping sites, only the area down-gradient from the up-slope edge of the distribution media may be included in this calculation.

  • Transboundary movement means any movement of hazardous wastes or other wastes from an area under the national jurisdiction of one State to or through an area under the national jurisdiction of another State or to or through an area not under the national jurisdiction of any State, provided at least two States are involved in the movement;

  • Drainage area means a geographic area within which stormwater, sediments, or dissolved materials drain to a particular receiving waterbody or to a particular point along a receiving waterbody.

  • Modular building retailer means any person who purchases or acquires a modular building from a

  • Generation Interconnection Feasibility Study means a study conducted by the Transmission Provider (in coordination with the affected Transmission Owner(s)) in accordance with Tariff, Part IV, section 36.

  • Interconnection Point means the point(s) of connection(s) at which the project is connected to the grid i.e. it shall be at 11 / 22 kV bus bar level of substation of MSEDCL.

  • Ozone season means the period of time beginning May 1 of a year and ending on September 30 of the same year, inclusive.

  • Winter Season means the period commencing on November 1 of any year and ending on the next succeeding March 31.

  • Baseline area means any intra- state area (and every part thereof) des- ignated as attainment or unclassifiable under section 107(d)(1)(A)(ii) or (iii) of the Act in which the major source or major modification establishing the minor source baseline date would con- struct or would have an air quality im- pact for the pollutant for which the baseline date is established, as follows: equal to or greater than 1 μg/m3 (an- nual average) for SO2, NO2, or PM10; or equal or greater than 0.3 μg/m3 (annual average) for PM2.5.(ii) Area redesignations under section 107(d)(1)(A)(ii) or (iii) of the Act cannot intersect or be smaller than the area of impact of any major stationary source or major modification which:

  • On-premise beer retailer means a beer retailer who is:

  • ILUA Area means the geographical area in relation to which the Framework ILUA applies, as specified in Schedule 2 of the Framework ILUA;

  • Combustion turbine means an enclosed fossil or other fuel-fired device that is comprised of a compressor, a combustor, and a turbine, and in which the flue gas resulting from the combustion of fuel in the combustor passes through the turbine, rotating the turbine.

  • Ultra Low Sulfur Diesel Fuel means diesel fuel that has a sulfur content of no more than fifteen parts per million.

  • Generator Forced Outage means an immediate reduction in output or capacity or removal from service, in whole or in part, of a generating unit by reason of an Emergency or threatened Emergency, unanticipated failure, or other cause beyond the control of the owner or operator of the facility, as specified in the relevant portions of the PJM Manuals. A reduction in output or removal from service of a generating unit in response to changes in market conditions shall not constitute a Generator Forced Outage.