Important Information About Procedures for Opening a New Account To help the government fight the funding of terrorism and money laundering activities, Federal law requires all financial organizations to obtain, verify, and record information that identifies each person who opens an account. What this means for you: When you open an account, you are required to provide your name, residential address, date of birth, and identification number. We may require other information that will allow us to identify you.
Examination of work before covering up In respect of the work which the Authority’s Engineer is entitled to examine, inspect, measure and/or test before it is covered up or put out of view or any part of the work is placed thereon, the Contractor shall give notice to the Authority’s Engineer whenever any such work is ready and before it is covered up. The Authority’s Engineer shall then either carry out the examination, inspection or testing without unreasonable delay, or promptly give notice to the Contractor that the Authority’s Engineer does not require to do so. Provided, however, that if any work is of a continuous nature where it is not possible or prudent to keep it uncovered or incomplete, the Contractor shall notify the schedule of carrying out such work to give sufficient opportunity, not being less than 3 (three) business days’ notice, to the Authority’s Engineer to conduct its inspection, measurement or test while the work is continuing. Provided further that in the event the Contractor receives no response from the Authority’s Engineer within a period of 3 (three) business days from the date on which the Contractor’s notice hereunder is delivered to the Authority’s Engineer, the Contractor shall be entitled to assume that the Authority’s Engineer would not undertake the said inspection.
Safety Program The Contractor shall design a specific safety program for the Work for the site(s). The Contractor shall establish and require all Subcontractors to establish reasonable safety programs. The Contractor shall also submit its standard monthly safety reports to the Owner and Design Professional. No imposition of responsibility on the Contractor for safety under this Contract shall relieve any subcontractor of its responsibility for safety of persons or property on or near the Project Site. The Contractor shall include in his plant he names of the person in charge of Safety.
Office of Inspector General Investigative Findings Expert Review In accordance with Senate Bill 799, Acts 2021, 87th Leg., R.S., if Texas Government Code, Section 531.102(m-1)(2) is applicable to this Contract, Contractor affirms that it possesses the necessary occupational licenses and experience.
Emergency Escalation initiated by ICANN Upon reaching 10% of the Emergency thresholds as described in Section 6 of this Specification, ICANN’s emergency operations will initiate an Emergency Escalation with the relevant Registry Operator. An Emergency Escalation consists of the following minimum elements: electronic (i.e., email or SMS) and/or voice contact notification to the Registry Operator’s emergency operations department with detailed information concerning the issue being escalated, including evidence of monitoring failures, cooperative trouble-‐shooting of the monitoring failure between ICANN staff and the Registry Operator, and the commitment to begin the process of rectifying issues with either the monitoring service or the service being monitoring.
Training Program It is agreed that there shall be an Apprenticeship Training Program, the provisions of which are set forth in Exhibit "D", which is attached hereto and forms part of this Agreement.
Project Implementation Manual The Recipient, through the PCU, shall: (i) take all action required to carry out Parts 1.1, 1.3, 1.4, 2, 3.1(b), 3.2, 3.3 and 4 (ii) of the Project in accordance with the provisions and requirements set forth or referred to in the Project Implementation Manual; (ii) submit recommendations to the Association for its consideration for changes and updates of the Project Implementation Manual as they may become necessary or advisable during Project implementation in order to achieve the objective of Parts 1.1, 1.3, 1.4, 2, 3.1(b), 3.2, 3.3 and 4(ii) of the Project; and (iii) not assign, amend, abrogate or waive the Project Implementation Manual or any of its provisions without the Association’s prior agreement. Notwithstanding the foregoing, if any of the provisions of the Project Implementation Manual is inconsistent with the provisions of this Agreement, the provisions of this Agreement shall prevail and govern.
Safety Procedures The Contractor shall: (a) comply with all applicable safety regulations according to Attachment H; (b) take care for the safety of all persons entitled to be on the Site; (c) use reasonable efforts to keep the Site and Works clear of unnecessary obstruction so as to avoid danger to these persons; (d) provide fencing, lighting, guarding and watching of the Works until completion and taking over under clause 10 [Employer's Taking Over]; and (e) provide any Temporary Works (including roadways, footways, guards and fences) which may be necessary, because of the execution of the Works, for the use and protection of the public and of owners and occupiers of adjacent land.
Examination and Review (i) After receipt of the Closing Working Capital Statement, Seller will have *** (***) days from the date on which Buyer has provided to Seller all access and information reasonably requested for such purposes (the “Review Period”) to review the Closing Working Capital Statement. During the Review Period, Seller and its accountants will have full access to the relevant books and records of Buyer, the personnel of, and work papers prepared by, Buyer and/or Buyer’s accountants to the extent that they relate to the Closing Working Capital Statement and to such historical financial information (to the extent in Buyer’s possession) relating to the Closing Working Capital Statement as Seller may reasonably request for the purpose of reviewing the Closing Working Capital Statement and to prepare a Statement of Objections. (ii) On or prior to the last day of the Review Period, Seller may object to the Closing Working Capital Statement by delivering to Buyer a written statement setting forth Seller’s objections in reasonable detail, indicating each disputed item or amount and the basis for Seller’s disagreement therewith (the “Statement of Objections”). If Seller fails to deliver the Statement of Objections before the expiration of the Review Period, then the Closing Working Capital Statement and the Post-Closing Adjustment, as the case may be, reflected in the Closing Working Capital Statement will be deemed to have been accepted by Seller. If Seller delivers the Statement of Objections before the expiration of the Review Period, Buyer and Seller will negotiate in good faith to resolve such objections within *** (***) days after the delivery of the Statement of Objections (the “Resolution Period”), and, if the same are so resolved within the Resolution Period, then the Post-Closing Adjustment and the Closing Working Capital Statement with such changes as may have been previously agreed in writing by Buyer and Seller, will be final and binding.
Post-Commercial Operation Date Testing and Modifications Each Party shall at its own expense perform routine inspection and testing of its facilities and equipment in accordance with Good Utility Practice as may be necessary to ensure the continued interconnection of the Large Generating Facility with the Participating TO’s Transmission System in a safe and reliable manner. Each Party shall have the right, upon advance written notice, to require reasonable additional testing of the other Party’s facilities, at the requesting Party’s expense, as may be in accordance with Good Utility Practice.