Major Decisions (A) Subject to Sections 7.3(C) and 7.3(D) with respect to the Company, all major decisions of the Company set forth below in clauses (A)(1) through (A)(6) (“Major Decisions”) shall be subject to the Company’s Articles of Incorporation and joint approval by the Advisor and Sub-advisor. For the avoidance of doubt, Major Decisions specifically exclude any decisions regarding the day-to-day operations of the Company, the decision-making authority for which has been delegated to the Sub-advisor pursuant to this Agreement. Major Decisions shall consist of the following: (1) Decisions to recommend to the Board of Directors that the Company acquire or sell Properties, Loans and other Permitted Investments; (2) Retention of investment banks for the Company; (3) Marketing methods for the Company’s sale of Shares; (4) Extending, initiating or terminating the Initial Public Offering or any subsequent Offering of the Shares; (5) Issuing press releases involving the major decisions of the Company or the Advisor or Sub-advisor or their Affiliates with respect to the business or operations of the Company; provided, that the Sub-advisor need not obtain consent to any press releases regarding acquisitions or dispositions of Properties, Loans or other Permitted Investments; and provided further, however, that notwithstanding the immediately preceding proviso, any mention of the Advisor or its Affiliates in such press releases regarding acquisitions or dispositions shall be pre-approved by the Advisor; and (6) Merging or otherwise engaging in any change of control transaction for the Company. (B) Notwithstanding anything in this Agreement to the contrary, if the Parties do not agree to any action constituting a Major Decision that is described in any of clauses (A)(2) through (A)(6) above and that has been proposed by either Party, the Parties shall meet (in person or by phone) to discuss the issue in dispute in good faith over the five-business day period beginning with the delivery of notice of the proposed action to the other Party. (C) Notwithstanding anything in this Agreement to the contrary, with respect to Major Decisions described in clause (A)(1) above (but subject to Section 7.3(D)), (1) joint approval shall not be required, (2) the Sub-advisor and the Advisor shall discuss the proposed transaction (either in person or by phone) prior to either Party making any recommendation of the proposed transaction to the Board of Directors, and (3) the Sub-Advisor and the Advisor shall each give due consideration to the opinions of the other Party. Ordinarily, such discussions shall begin at least five business days before a recommendation is made to the Board of Directors; however, if in the sole discretion of the Sub-advisor it is in the best interest of the Company to make a recommendation to the Board of Directors more promptly, then the Sub-advisor may do so. In the event the Parties do not agree as to whether to recommend the proposed transaction to the Board of Directors, the Sub-advisor’s decision shall govern. (D) Notwithstanding the provisions of this Section 7.3 or any other provision in this Agreement to the contrary, in all events, including Major Decisions, the Company will be managed under the direction of the Board of Directors. (E) Notwithstanding anything in this Agreement to the contrary (but subject to Section 7.3(D)), the Sub-advisor shall have sole authority to act on behalf of the Company regarding amending the Advisory Agreement.
Schematic Design See Section 2, Part 1, Article 2.1.4, Paragraph 2.1.4.2.
Investment Decisions The Subadviser shall determine from time to time what investments and securities will be purchased, retained, sold or loaned by the Series, and what portion of such assets will be invested or held uninvested as cash.
Arbitration Decisions Unless otherwise agreed by the Parties, the arbitrator(s) shall render a decision within ninety (90) Calendar Days of appointment and shall notify the Parties in writing of such decision and the reasons therefor. The arbitrator(s) shall be authorized only to interpret and apply the provisions of this LGIA and shall have no power to modify or change any provision of this Agreement in any manner. The decision of the arbitrator(s) shall be final and binding upon the Parties, and judgment on the award may be entered in any court having jurisdiction. The decision of the arbitrator(s) may be appealed solely on the grounds that the conduct of the arbitrator(s), or the decision itself, violated the standards set forth in the Federal Arbitration Act or the Administrative Dispute Resolution Act. The final decision of the arbitrator(s) must also be filed with FERC if it affects jurisdictional rates, terms and conditions of service, Interconnection Facilities, or Network Upgrades.
Automated decisions For purposes hereof “automated decision” shall mean a decision by the data exporter or the data importer which produces legal effects concerning a data subject or significantly affects a data subject and which is based solely on automated processing of personal data intended to evaluate certain personal aspects relating to him, such as his performance at work, creditworthiness, reliability, conduct, etc. The data importer shall not make any automated decisions concerning data subjects, except when: a) i. such decisions are made by the data importer in entering into or performing a contract with the data subject, and
Schematic Design Documents In accordance with the approved Preliminary Design and Construction Schedule and based upon approval of and comments made by the Owner regarding the Concept Design Studies, the Design Professional shall prepare and submit to the Owner Schematic Design Documents, including drawings and outline specifications. These documents shall represent a further development of the approved design concept, providing additional detail and specificity regarding the intended design solution. Typically, all such documents shall be drawn to scale, indicating materials and assemblies, as appropriate, to convey the design intent and to illustrate the Project’s basic elements, scale and relationship to the Site. All major pieces of furniture and equipment to be fixed or supplied by the CM/GC shall be illustrated to scale. (See ASTM Standard Practice E 1804-02, August 2007, Sections 6.3, 8.2 and 8.3 for guidance on information which is generally developed in Schematic Design.)
Investment Decision The Purchaser understands that nothing in the Agreement or any other materials presented to the Purchaser in connection with the purchase and sale of the Shares constitutes legal, tax or investment advice. The Purchaser has consulted such legal, tax and investment advisors as it, in its sole discretion, has deemed necessary or appropriate in connection with its purchase of the Shares.
Final Decision Concessionaire covenants that the decision of the Commissioner of Department, relative to the performance of the terms and conditions of this Agreement, shall be final and conclusive.
SITE-BASED DECISION MAKING A. The District shall provide the training and staff development to support accountability/site- based decision-making activities. Teachers shall be given release time to attend these programs. B. Participation on the SAC shall not serve as a basis for the evaluation of any teacher. C. A minimum of three (3) to a maximum of five (5) teachers from each school shall serve on their school’s budget advisory committee formed for the purpose of making recommendations on the school’s general fund budget. Teacher members shall be elected by the faculty. Minutes from such meetings may be requested by the faculty and may be posted on the CTA bulletin board at the school by the Association Representative.
Schematic Design Phase 1.2.1 Based on the mutually agreed upon Program of Requirements, Amount Available for the Construction Contract and the Project Schedule, the Architect/Engineer shall prepare sufficient alternative approaches utilizing BIM for design and construction of the Project to satisfy Owner’s project requirements and shall, at completion of this phase, submit Schematic Design Documents derived from the model in accordance with the BIM Execution Plan, “Facility Design Guidelines” and any additional requirements set forth in Article 15. The Architect/Engineer shall review alternative approaches to design and construction for the Project as they are being modeled at intervals appropriate to the progress of the Project with the Owner and Construction Manager at the Project site or other location specified by the Owner within the State of Texas. The Architect/Engineer shall utilize the model(s) to support the review process during Schematic Design. The Architect/Engineer shall provide the Construction Manager with a compact disc containing documents and data files derived from the model to assist the Construction Manager in fulfilling its responsibilities to the Owner. 1.2.2 Architect/Engineer shall provide all services necessary to perform the services of this phase (preparation of model(s), relevant data, decision support model views and Schematic Design Documents) including, without limitation, unless otherwise approved by Owner, the preparation and prompt delivery of all items specified in the BIM Execution Plan and “Facility Design Guidelines”. 1.2.3 Architect/Engineer shall work closely with Owner in preparation of schematic drawings and shall specifically conform to Owner’s requirements regarding aesthetic design issues. 1.2.4 The Architect/Engineer shall review the Estimated Construction Cost prepared by the Construction Manager, and shall provide written comments. 1.2.5 Before proceeding into the Design Development Phase, the Architect/Engineer shall obtain Owner’s written acceptance of the Schematic Design documents and approval of the Architect/Engineer’s preliminary Estimated Construction Cost and schedule. 1.2.6 The Architect/Engineer shall participate in a final review of the Schematic Design Documents and model(s) with the Owner and Construction Manager at the Project site or other location specified by Owner in the State of Texas. Prior to the Owner’s approval of the Schematic Design Documents, the Architect/Engineer shall incorporate such changes as are necessary to satisfy the Owner’s review comments, any of which may be appealed for good cause.