Bandwidth Measurement. Bandwidth usage will be calculated by Hurricane using the 95th percentile of samplings taken at 5 minute intervals on a monthly basis. Samples are taken by Hurricane via SNMP from the Hurricane switch or router port Customer is directly connected to and are the greater of input or output bits per second. 95th percentile is determined by sorting the sample data from smallest to largest and discarding the top 5 percent, with the remaining largest sample designated as the 95th percentile. APPENDIX B: COLOCATION IN HURRICANE ELECTRIC FACILITIES This appendix only applies if Customer is receiving Colocation from Hurricane Electric in a Hurricane Electric data center. B.1 Use of Space. Hurricane grants Customer the right to operate Customer Equipment at the Colocation Space, as specified on Customer’s Order. Except as specifically provided herein, Customer expressly assumes all risk of loss to Customer Equipment in the Colocation Space. Customer shall be liable to Hurricane for any damage to the Colocation facility, Hurricane Equipment or equipment of other Hurricane customers caused by Customer, Customer Equipment, or Customer’s personnel. Customer Equipment shall be industry-accepted information and communication technology equipment suitable for use in a data center. B.2 Customer Equipment Installation and Removal. Customer is responsible for all aspects of installation and removal of Customer Equipment, including bringing appropriate equipment, tools and packaging materials. Customer will install Customer Equipment in the Colocation Space after obtaining the appropriate authorization from Hurricane to access Hurricane premises. Customer will remove all packaging for Customer Equipment promptly after installation. Should Customer use an agent or other third party to deliver, install or remove Customer Equipment, Customer will be solely responsible for the acts of such party. At Customer’s option, Hurricane will remove and package Customer Equipment and place Customer Equipment in a designated area for pick-up, on the condition that Customer either provide or pay for all needed packaging plus pay Hurricane’s packaging fees and charges. Within five (5) days after authorization from Hurricane, Customer will remove Customer Equipment from the designated area or arrange on a pre-paid basis for a carrier to pick-up and ship such equipment to Customer. Customer may request remote hands service for the purpose of installation of equipment that has been shipped precon...
AutoNDA by SimpleDocs
Bandwidth Measurement. A. Burstable Maximums: Available at 3 x CIR (committed information rate) or up to the provisioned port speed or a max of 10 Gbps, whichever is lower. 1. For example: (a) Customer has a 30Mbps service on a 100Mbps port, and Customer can burst up to 90Mbps; (b) Customer has purchased a 50Mbps service and is on a 100Mbps port. Customer can burst up to 100Mbps; (c) Customer has a 5Gbps service (CIR) on a 10Gbps port, the max is 10Gbps so no bursting beyond the 10Gbps. 2. Customer is not guaranteed the bandwidth beyond what they purchased as a base service. B. Measurement: When Customer purchases FirstLight Internet Service that is a burstable service, bandwidth usage will be calculated by FirstLight using the 95th percentile of samplings taken at five (5) minute intervals on a monthly basis. Samples are taken by FirstLight via SNMP from the FirstLight switch or router port the Customer is directly connected to and the results are the greater of input or output bits per second. The 95th percentile is determined by sorting the sample data from the smallest to the largest and discarding the top 5%, with the remaining largest sample designated as the 95th percentile.

Related to Bandwidth Measurement

  • Usage Measurement Usage measurement for calls shall begin when answer supervision or equivalent Signaling System 7 (SS7) message is received from the terminating office and shall end at the time of call disconnect by the calling or called subscriber, whichever occurs first.

  • Mileage Measurement Where required, the mileage measurement for LIS rate elements is determined in the same manner as the mileage measurement for V&H methodology as outlined in NECA Tariff No. 4.

  • Temperature Measurement Temperature will be measured by the nearest automatic Melbourne Bureau of Meteorology Monitoring Station for example (but not limited to): Melbourne, Moorabbin, Dunns Hill, Melbourne Airport, Frankston, and Point Xxxxxx. At the commencement of each project, the onsite management and employee representatives shall agree which is to be the applicable automatic weather monitoring station.

  • Measurement Should the State terminate this contract as herein provided, no fees other than fees due and payable at the time of termination shall thereafter be paid to the Engineer. In determining the value of the work performed by the Engineer prior to termination, the State shall be the sole judge. Compensation for work at termination will be based on a percentage of the work completed at that time. Should the State terminate this contract under paragraph (4) or (5) above, the Engineer shall not incur costs during the thirty-day notice period in excess of the amount incurred during the preceding thirty days.

  • Performance Measurement The Uniform Guidance requires completion of OMB-approved standard information collection forms (the PPR). The form focuses on outcomes, as related to the Federal Award Performance Goals that awarding Federal agencies are required to detail in the Awards.

  • Benchmarks for Measuring Accessibility For the purposes of this Agreement, the accessibility of online content and functionality will be measured according to the W3C’s Web Content Accessibility Guidelines (WCAG) 2.0 Level AA and the Web Accessibility Initiative Accessible Rich Internet Applications Suite (WAI-ARIA) 1.0 for web content, which are incorporated by reference.

  • Start-Up and Synchronization Consistent with the mutually acceptable procedures of the Developer and Connecting Transmission Owner, the Developer is responsible for the proper synchronization of the Large Generating Facility to the New York State Transmission System in accordance with NYISO and Connecting Transmission Owner procedures and requirements.

  • Unbundled Channelization (Multiplexing) 5.7.1 To the extent NewPhone is purchasing DS1 or DS3 or STS-1 Dedicated Transport pursuant to this Agreement, Unbundled Channelization (UC) provides the optional multiplexing capability that will allow a DS1 (1.544 Mbps) or DS3 (44.736 Mbps) or STS-1 (51.84 Mbps) Network Elements to be multiplexed or channelized at a BellSouth central office. Channelization can be accomplished through the use of a multiplexer or a digital cross-connect system at the discretion of BellSouth. Once UC has been installed, NewPhone may request channel activation on a channelized facility and BellSouth shall connect the requested facilities via COCIs. The COCI must be compatible with the lower capacity facility and ordered with the lower capacity facility. This service is available as defined in NECA 4. 5.7.2 BellSouth shall make available the following channelization systems and interfaces: 5.7.2.1 DS1 Channelization System: channelizes a DS1 signal into a maximum of twenty- four (24)

  • Measuring EPP parameters Every 5 minutes, EPP probes will select one “IP address” of the EPP servers of the TLD being monitored and make an “EPP test”; every time they should alternate between the 3 different types of commands and between the commands inside each category. If an “EPP test” result is undefined/unanswered, the EPP service will be considered as unavailable from that probe until it is time to make a new test.

  • Measurement and Billing 5.6.1 For billing purposes, each Party shall pass Calling Party Number ("CPN") information on each call carried over the Traffic Exchange Trunks at such time as the originating switch is equipped for SS7 and from all switches no later than December 31, 1998. At such time as either Party has the ability, as the Party receiving the traffic, to use such CPN information to classify on an automated basis traffic delivered by the other Party as either Local Traffic or Toll Traffic, such receiving Party shall xxxx the originating Party the Local Traffic termination rates, Intrastate Exchange Access rates, or Interstate Exchange Access rates applicable to each minute of Traffic for which CPN is passed, as provided in Exhibit A and applicable Tariffs. 5.6.2 If, under the circumstances set forth in subsection 5.6.1, the originating Party does not pass CPN on up to ten percent (10%) of calls, the receiving Party shall xxxx the originating Party the Local Traffic termination rates, Intrastate Exchange Access rates, Intrastate/Interstate Transit Traffic rates, or Interstate Exchange Access rates applicable to each minute of traffic, as provided in Exhibit A and applicable Tariffs, for which CPN is passed. For the remaining up to ten percent (10%) of calls without CPN information, the receiving Party shall xxxx the originating Party for such traffic as Local Traffic termination rates, Intrastate Exchange Access rates, Intrastate/Interstate Transit Traffic rates, or Interstate Exchange Access rates applicable to each minute of traffic, as provided in Exhibit A and applicable Tariffs, in direct proportion to the minutes of use of calls passed with CPN information. 5.6.3 If the originating Party does not pass CPN on more than ten percent (10%) of calls, or if the receiving Party lacks the ability to use CPN information to classify on an automated basis traffic delivered by the other Party as either Local Traffic or Toll Traffic, and the originating Party chooses to combine Local and Toll Traffic on the same trunk group, it will supply an auditable Percent Local Use ("PLU") report quarterly, based on the previous three months' traffic, and applicable to the following three months. If the originating Party also chooses to combine Interstate and Intrastate Toll Traffic on the same trunk group, it will supply an auditable Percent Interstate Use ("PIU") report quarterly, based on the previous three months' terminating traffic, and applicable to the following three months. In lieu of the foregoing PLU and/or PIU reports, the Parties may agree to provide and accept reasonable surrogate measures for an agreed-upon interim period. 5.6.4 Measurement of billing minutes for purposes of determining terminating compensation shall be in conversation seconds.