Bus Duct Sample Clauses

Bus Duct. This section covers the design, manufacture and installation of completely coordinated isolated phase bus duct for the gas turbine generator and, if required by Contractor's design, 4.16kV nonsegregated bus duct for station auxiliaries. The bus duct shall be designed, manufactured and tested in accordance with the latest applicable ANSI, IEEE and NEMA standards. The Contractor shall furnish and install the bus duct system complete with all equipment and accessories including, but not limited to, the following: -------------------------------------------------------------------------------- EPC - Exhibit B -------------------- TENASKA GEORGIA GENERATION PROJECT Page 100 of 132 -------------------------------------------------------------------------------- - isolated phase bus duct between the gas turbine generators and main step-up power transformers, - if required by the Contractor's design, the three (3) 4.16kV nonsegregated bus ducts from the auxiliary power transformers to the 4.16kV switchgear, - supporting structures, and - disconnect links. The phase bus conductors shall be either copper or aluminum alloy. The bus enclosures shall be steel or aluminum alloy with manufacturer's standard hardware for indoor sections and stainless steel for outdoor sections. Supporting structures shall be ASTM A36 steel with the outdoor structures being hot-dipped galvanized. Outdoor bus duct section shall be provided with space heaters to maintain an internal duct temperature above the dew point. All bolted connections of the bus conductors shall be silver-plated for copper bus and tin-plated for aluminum. Provide continuous copper bar ground bus the full length of the bus duct and electrically connecting all enclosure sections. If the bus duct is constructed to provide a continuous path for ground current the enclosure may serve as the ground bus. Taps or connections shall be provided, as required, to accommodate auxiliary equipment such as lightning and surge protection, generator controls, metering and relaying, and current and potential transformers. Removable covers shall be provided to permit access to the interior of the enclosure. After fabrication, all metalwork of the enclosures shall be thoroughly cleaned and any steel work shall be phosphorized, or equivalent, and shall be painted with xxxx ANSI 61, or equivalent, paint. Design and production tests shall be per ANSI requirements.
AutoNDA by SimpleDocs

Related to Bus Duct

  • Data Protection During Transmission DST shall encrypt, using an industry standard encryption algorithm, personally identifiable Fund Data when such data is transmitted.

  • Transit Traffic 7.2.2.3.1 CenturyLink will accept traffic originated by CLEC’s network and/or its end user(s) for termination to other Telecommunications Carrier’s network and/or its end users that is connected to CenturyLink's Switch. CenturyLink will also terminate traffic from these other Telecommunications Carriers’ network and/or its end users to CLEC’s network and/or its end users. For purposes of the Agreement, transit traffic does not include traffic carried by Interexchange Carriers. That traffic is defined as Jointly Provided Switched Access. 7.2.2.3.2 The Parties involved in transporting transit traffic will deliver calls to each involved network with CCS/SS7 protocol and the appropriate ISUP/TCAP messages to facilitate full Interoperability and Billing functions. 7.2.2.3.3 The originating company is responsible for payment of appropriate rates to the transit company and to the terminating company. The Parties agree to enter into traffic exchange agreements with third party Telecommunications Carriers prior to delivering traffic to be transited to third party Telecommunications Carriers. In the event one Party originates traffic that transits the second Party’s network to reach a third party Telecommunications Carrier with whom the originating Party does not have a traffic exchange agreement, then the originating Party will indemnify, defend and hold harmless the second Party against any and all charges levied by such third party Telecommunications Carrier, including any termination charges related to such traffic and any attorneys fees and expenses. In the case of IntraLATA LEC Toll traffic where CenturyLink is the designated IntraLATA Toll provider for existing LECs, CenturyLink will be responsible for payment of appropriate usage rates. 7.2.2.3.4 When CenturyLink receives an unqueried call from CLEC to a telephone number that has been ported to another local services provider, the transit rate will apply in addition to any query rates. 7.2.2.3.5 In the case of a transit call that terminates in the Local Calling Area but in a different state than the call originated, and the CLEC does not have an agreement with CenturyLink in the state where the transit call terminated, CLEC must execute an agreement for that state if it is a state served by CenturyLink. In the absence of a second agreement, the transit rate in Exhibit A of this Agreement will be billed to the CLEC.

  • Dark Fiber Transport Dark Fiber Transport is defined as Dedicated Transport that consists of unactivated optical interoffice transmission facilities without attached signal regeneration, multiplexing, aggregation or other electronics. Except as set forth in Section 6.9.1 below, BellSouth shall not be required to provide access to Dark Fiber Transport Entrance Facilities pursuant to this Agreement.

  • Unbundled Channelization (Multiplexing) 5.7.1 To the extent NewPhone is purchasing DS1 or DS3 or STS-1 Dedicated Transport pursuant to this Agreement, Unbundled Channelization (UC) provides the optional multiplexing capability that will allow a DS1 (1.544 Mbps) or DS3 (44.736 Mbps) or STS-1 (51.84 Mbps) Network Elements to be multiplexed or channelized at a BellSouth central office. Channelization can be accomplished through the use of a multiplexer or a digital cross-connect system at the discretion of BellSouth. Once UC has been installed, NewPhone may request channel activation on a channelized facility and BellSouth shall connect the requested facilities via COCIs. The COCI must be compatible with the lower capacity facility and ordered with the lower capacity facility. This service is available as defined in NECA 4. 5.7.2 BellSouth shall make available the following channelization systems and interfaces: 5.7.2.1 DS1 Channelization System: channelizes a DS1 signal into a maximum of twenty- four (24)

  • Tandem Transit Traffic ‌ 12.1 As used in this Section, Tandem Transit Traffic is Telephone Exchange Service traffic that originates on Onvoy's network, and is transported through Frontier’s Tandem to the subtending End Office or its equivalent of another carrier (CLEC, ILEC other than Frontier, Commercial Mobile Radio Service (CMRS) carrier, or other LEC (“Other Carrier”). Neither the originating nor terminating customer is a Customer of Frontier. Subtending End Offices shall be determined in accordance with and as identified in the Local Exchange Routing Guide (LERG). For the avoidance of any doubt, under no circumstances shall Frontier be required to transit traffic through a Frontier Tandem to a Central Office that the LERG does not identify as subtending that particular Frontier Tandem. Switched Exchange Access Service traffic is not Tandem Transit Traffic. 12.2 Tandem Transit Traffic Service provides Onvoy with the transport of Tandem Transit Traffic as provided below. 12.3 Tandem Transit Traffic may be routed over the Interconnection Trunks described in Sections 2 through 6 of this Attachment. Onvoy shall deliver each Tandem Transit Traffic call to Frontier’s Tandem with CCS and the appropriate Transactional Capabilities Application Part (“TCAP”) message to facilitate full interoperability of CLASS Features and billing functions. 12.4 Onvoy may use Tandem Transit Traffic Service only for traffic that originates on Onvoy’s network and only to send traffic to an Other Carrier with whom Onvoy has a reciprocal traffic exchange arrangement (either via written agreement or mutual tariffs) that provides for the Other Carrier, to terminate or complete traffic originated by Onvoy and to bill Onvoy, and not to bill Frontier, for such traffic. Onvoy agrees not to use Frontier’s Tandem Transit Traffic Service to send traffic to an Other Carrier with whom Onvoy does not have such a reciprocal traffic exchange arrangement or to send traffic that does not originate on Onvoy’s network. 12.5 Onvoy shall pay Frontier for Tandem Transit Traffic Service at the rates specified in the Pricing Attachment. Frontier will not be liable for compensation to any Other Carrier for any traffic that is transported through Frontier’s Tandem and Frontier reserves the right to assess to Onvoy any additional charges or costs any Other Carrier imposes or levies on Frontier for the delivery or termination of such traffic, including any Switched Exchange Access Service charges. If Frontier is billed by any Other Carrier for any traffic originated by Onvoy, Frontier may provide notice to Onvoy of such billing. Upon receipt of such notice, Onvoy shall immediately stop using Frontier’s Tandem Transit Traffic Service to send any traffic to such Other Carrier until it has provided to Frontier certification that the Other Carrier has removed such billed charges from its bill to Frontier and that the Other Carrier will not bill Frontier for any traffic originated by Onvoy. Such certification must be signed by an authorized officer or agent of the Other Carrier and must be in a form acceptable to Frontier. 12.6 If Onvoy uses Tandem Transit Traffic Service for traffic volumes that exceed the Centum Call Seconds (Hundred Call Seconds) busy hour equivalent of 200,000 combined minutes of use per month (a DS1 equivalent) to the subtending End Office of a particular Other Carrier for any month (the “Threshold Level”). Onvoy shall use good faith efforts to establish direct interconnection with such Other Carrier and reduce such traffic volumes below the Threshold Level. If Frontier believes that Xxxxx has not exercised good faith efforts promptly to obtain such direct interconnection, either Party may use the Dispute Resolution processes of this Agreement. 12.7 If Onvoy fails to comply with Section 12 of this Attachment, such failure shall be a material breach of a material provision of this Agreement and Frontier may exercise any and all remedies under this Agreement and Applicable Law for such breach. 12.8 If or when a third party carrier plans to subtend an Onvoy switch, then Onvoy shall provide written notice to Frontier at least ninety (90) days before such subtending service arrangement becomes effective so that Frontier may negotiate and establish direct interconnection with such third party carrier. Upon written request from Frontier, Onvoy shall offer to Frontier a service arrangement equivalent to or the same as Tandem Transit Traffic Service provided by Frontier to Onvoy as defined in this Section such that Frontier may terminate calls to a Central Office or its equivalent of a CLEC, ILEC other than Frontier, CMRS carrier, or other LEC, that subtends an Onvoy Central Office or its equivalent (“Reciprocal Tandem Transit Service”). Onvoy shall offer such Reciprocal Transit Service arrangements under terms and conditions of an amendment to this Agreement or a separate agreement no less favorable than those provided in this Section. 12.9 Neither Party shall take any actions to prevent the other Party from entering into a direct and reciprocal traffic exchange arrangement with any carrier to which it originates, or from which it terminates, traffic.

  • Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Xxxx has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Xxxx. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Xxxx (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Xxxx, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Xxxx will then have the option of paying the one-time SC rates to place the Loop.

  • NYISO and Connecting Transmission Owner Obligations Connecting Transmission Owner and NYISO shall cause the New York State Transmission System and the Connecting Transmission Owner’s Attachment Facilities to be operated, maintained and controlled in a safe and reliable manner in accordance with this Agreement and the NYISO Tariffs. Connecting Transmission Owner and NYISO may provide operating instructions to Developer consistent with this Agreement, NYISO procedures and Connecting Transmission Owner’s operating protocols and procedures as they may change from time to time. Connecting Transmission Owner and NYISO will consider changes to their respective operating protocols and procedures proposed by Developer.

  • Two-Way Interconnection Trunks 2.4.1 Where the Parties have agreed to use Two-Way Interconnection Trunks for the exchange of traffic between Verizon and PCS, PCS shall order from Verizon, and Verizon shall provide, the Two-Way Interconnection Trunks and the Entrance Facility, on which such Trunks will ride, and transport and multiplexing, in accordance with the rates, terms and conditions set forth in this Agreement and Verizon’s applicable Tariffs. 2.4.2 Prior to ordering any Two-Way Interconnection Trunks from Verizon, PCS shall meet with Verizon to conduct a joint planning meeting (“Joint Planning Meeting”). At that Joint Planning Meeting, each Party shall provide to the other Party originating Centium Call Second (Hundred Call Second) information, and the Parties shall mutually agree on the appropriate initial number of Two-Way End Office and Tandem Interconnection Trunks and the interface specifications at the Point of Interconnection (POI). Where the Parties have agreed to convert existing One-Way Interconnection Trunks to Two-Way Interconnection Trunks, at the Joint Planning Meeting, the Parties shall also mutually agree on the conversion process and project intervals for conversion of such One-Way Interconnection Trunks to Two-Way Interconnection Trunks. 2.4.3 Two-Way Interconnection Trunks shall be from a Verizon End Office or Tandem to a mutually agreed upon POI. 2.4.4 On a semi-annual basis, PCS shall submit a good faith forecast to Verizon of the number of End Office and Tandem Two-Way Interconnection Trunks that PCS anticipates Verizon will need to provide during the ensuing two (2) year period to carry traffic from PCS to Verizon and from Verizon to PCS. PCS’s trunk forecasts shall conform to the Verizon CLEC trunk forecasting guidelines as in effect at that time. 2.4.5 The Parties shall meet (telephonically or in person) from time to time, as needed, to review data on End Office and Tandem Two-Way Interconnection Trunks to determine the need for new trunk groups and to plan any necessary changes in the number of Two-Way Interconnection Trunks. 2.4.6 Two-Way Interconnection Trunks shall have SS7 Common Channel Signaling. The Parties agree to utilize B8ZS and Extended Super Frame (ESF) DS1 facilities, where available. 2.4.7 With respect to End Office Two-Way Interconnection Trunks, both Parties shall use an economic Centium Call Second (Hundred Call Second) equal to five (5). 2.4.8 Two-Way Interconnection Trunk groups that connect to a Verizon access Tandem shall be engineered using a design blocking objective of Xxxx-Xxxxxxxxx B.005 during the average time consistent busy hour. Two-Way Interconnection Trunk groups that connect to a Verizon local Tandem shall be engineered using a design blocking objective of Xxxx-Xxxxxxxxx B.01 during the average time consistent busy hour. Verizon and PCS shall engineer Two-Way Interconnection Trunks using BOC Notes on the LEC Networks SR-TSV-002275. 2.4.9 The performance standard for final Two-Way Interconnection Trunk groups shall be that no such Interconnection Trunk group will exceed its design blocking objective (B.005 or B.01, as applicable) for three

  • Signaling Link Transport 9.2.1 Signaling Link Transport is a set of two or four dedicated 56 kbps transmission paths between Global Connection-designated Signaling Points of Interconnection that provide appropriate physical diversity.

  • First Aid Kits The Employer shall provide an area, equipped with a first-aid kit, for the use of Employees taken ill during working hours.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!