Capabilities of Meters Sample Clauses

Capabilities of Meters. The Facility Unit Metering Installation and the System Metering Installation shall be capable of measuring and recording the following parameters for various time and frequency blocks in accordance with applicable Laws and the Codes:
AutoNDA by SimpleDocs
Capabilities of Meters. 12.4.1 The Facility Metering Installation and the System Metering Installation shall be capable of measuring and recording the following parameters for various time and frequency blocks in accordance with applicable Laws and the Codes: 12.4.1.1 Energy Output and Reactive Energy Output; 12.4.1.2 instantaneous voltage, current and power factor; 12.4.1.3 frequency; 12.4.1.4 maximum demand in MVA/MW for each demand period and for the total period since the last reset; 12.4.1.5 MWh/MVARh since last reading; 12.4.1.6 real time and time of day metering; and 12.4.1.7 number of resets. 12.4.2 The Facility Metering Installation and the System Metering Installation shall also have the capability to download and transmit such real time data to a Supervisory Control and Data Acquisition ("SCADA") system, in a form and format suitable for SCADA. 12.4.3 The Buyer shall be entitled to, and the Facility Metering Installation shall enable the Buyer to, access the Facility Metering Installation and its data remotely at any time and without any notice.
Capabilities of Meters. 11.4.1 The Facility Metering Installation and the System Metering Installation shall be capable of measuring and recording the following parameters for various time and frequency blocks in accordance with applicable Laws and the Codes: (a) active Energy Output and Reactive Energy Output; (b) instantaneous voltage, current and power factor; (c) frequency; (d) maximum demand in MVA/MW for each demand period and for the total period since the last reset; (e) MWh/MVARh since last reading; (f) real time and time of day metering; and (g) number of resets.

Related to Capabilities of Meters

  • Personnel, Office Space, and Facilities of Manager The Manager at its own expense shall furnish or provide and pay the cost of such office space, office equipment, office personnel, and office services as the Manager requires in the performance of its investment advisory and other obligations under this Agreement.

  • Responsibilities of the District 12.1. The District shall examine the documents submitted by the Architect and shall render decisions so as to avoid unreasonable delay in the process of the Architect’s Services. 12.2. The District shall verbally or in writing advise Architect if the District becomes aware of any fault or defect in the Project, including any errors, omissions or inconsistencies in the Architect’s documents. Failure to provide such notice shall not relieve Architect of its responsibility therefore, if any. 12.3. Unless the District and Architect agree that a hazardous materials consultant shall be a Consultant of the Architect, the District shall furnish the services of a hazardous material consultant or other consultants when such services are requested in writing by Architect and deemed necessary by the District or are requested by the District. These services shall include: asbestos and lead paint survey; abatement documentation; and specifications related to said matters, which are to be incorporated into bid documents prepared by Architect. If the hazardous materials consultant is furnished by the District and is not a Consultant of the Architect, the specifications shall include a note to the effect that the hazardous materials consultant’s specifications are included in the Architect’s bid documents for the District’s convenience and have not been prepared or reviewed by the Architect. The note shall also direct questions about the hazardous materials consultant’s specifications related to asbestos and lead paint survey and/or abatement documentation to the preparer of the hazardous materials consultant’s specifications.

  • RESPONSIBILITIES OF THE UNIVERSITY The UNIVERSITY shall designate in writing a faculty member to coordinate with a designee of the FIELDWORK SITE.

  • Utilities; Amenities The following utilities are included in the Total Rent set forth in this Agreement: Internet access and trash disposal. Resident will pay as additional Rent a pro-rata share (based on the number of contracted residents in possession for the applicable period) for the apartment's usage of electricity and water, applied pro-rata to any partial billing cycle. Resident will be responsible for his or her pro-rata share of electricity and water charges during the term of this Agreement, regardless of actual date of move-in or move-out. No refund or credit will be provided for usage below any applicable allowance levels. In connection with the administration of utility billing during the term of this Agreement, Resident will pay prior to occupying the assigned apartment (or on the first utility bill, at Owner's discretion), a single up-front billing service fee of up to $72.00 (or alternately, at Owner's option, a service fee of up to $6.00 per monthly bill) for administration, billing, overhead and similar expenses and charges incurred by Owner for providing utility allocations and billing services. Upon Resident's request, Owner will provide copies of applicable utility bills. At Owner's option, to the extent permitted by law, Resident may be pre-billed for the estimated amount of charges for any electricity and/or water bills anticipated to be received during the final 30 days of the term or after the end of the term of this Agreement, calculated based on historical electricity and/or water charges for the apartment and pursuant to applicable utility billing laws and regulations. As part of each utility bill, Resident may be charged and agrees to pay promptly to Owner any other miscellaneous charges billed by the utility provider and payable by the customer of record, plus late payment fees and/or NSF fees, as may be applicable, in the amounts stated in paragraph 2 of this Agreement, as liquidated estimates of costs incurred in connection with the administration and collection of late payment. Owner may elect to use one or more third-party service providers for providing, billing and/or servicing utility accounts; Resident acknowledges that such third-party providers are not utility providers. Owner makes no representations and hereby disclaims any and all warranties, express or implied, with respect to any utilities provided, including but not limited to those warranties concerning merchantability and fitness for a particular purpose or use, whether made allegedly by Owner or its representatives or agents, whether in writing or otherwise, except as otherwise expressly stated in this Agreement. Owner does not warrant or guarantee the protection of Resident's privacy during operation of utilities, that such utilities will satisfy Resident's requirements, or that the operation of utilities will be uninterrupted or error free. Resident acknowledges and agrees that neither Owner nor its affiliates, agents, employees or representatives will be responsible to Resident for any non-economic, consequential, incidental, indirect or special damages, including incidental, economic or punitive damages, arising from breach of warranty, breach of contract, negligence or any other legal ground of action, or by reason of the use, discontinuation or modification of any utilities or the termination of any utilities, whether arising from Resident's use of (or inability to use) utilities, or otherwise, even if Owner has been advised of the possibility of such damage. In the event that any utility service proves defective, or is discontinued or terminated, Owner's and Manager's entire combined liability and Resident's exclusive remedy will be limited to a reimbursement of the approximate cost of that utility incurred by Resident, prorated by the day for each day the utility service proved defective, or was discontinued or terminated, for more than 24 hours. Resident agrees to indemnify, defend and hold harmless Owner and its employees, affiliates and agents, from any and all losses, claims, damages, expenses, other liabilities and causes of action of every nature, including attorney fees, which arise directly or indirectly in connection with: (i) violation by Resident of any laws, ordinances, regulations or rules regarding the utilities; or (ii) illegal or inappropriate use of the utilities. Any damage or loss to any utility devices during Resident's occupancy will be charged to Resident (and the other resident(s) in the apartment, as applicable) at the replacement cost. Management will establish schedules and policies for the use of recreation facilities, amenities and other common spaces. Owner may add, remove, close (temporarily or permanently), upgrade or modify any of the recreation facilities, amenities or common spaces in Owner's discretion, without notice or compensation; provided that if this Agreement expressly includes a separate Amenity Fee, Resident's sole remedy will be limited to a pro-rata credit of such Amenity Fee for the period a covered amenity is closed or fully unavailable. SAMPLE

  • Utilities and Services Tenant shall pay all charges for water, gas, ---------------------- electricity, telephone, central station monitor, refuse pickup, janitorial services, and all other utilities and services supplied or furnished to the Premises during the term of this Lease, together with any taxes thereon. Said utilities may be supplied to Tenant in common with any other tenant(s) in the Building, or at Landlord's or Tenant's option, be separately metered at Tenant's expense. If separately metered, or if the Premises consist of the entire building Tenant shall pay all such charges directly to the charging authority when due. If not separately metered, Tenant shall pay its allocable portion based upon the ratio between the Premises Gross Leasable Area and the total gross leasable square feet of space served by the common utility. However, if Landlord determines that Tenant is using a disproportionate amount of any utility service not separately metered, then Landlord may either install a separate meter to measure the utility service, at Tenant's cost, or charge Tenant a sum equal to Landlord's reasonable estimate of the cost of Tenant's excess use of such utility service. Tenant shall reimburse Landlord on a monthly basis for landlord's cost in furnishing utilities and services to the Premises within ten (10) days after Tenant receives an invoice from Landlord and in no event shall Landlord be liable to Tenant for any such failure or interruption unless caused by the misconduct of Landlord. No failure or interruption of any such utilities or services shall entitle Tenant to terminate this Lease or to withhold rent or other sums due hereunder and unless otherwise specifically provided herein. Landlord shall not be responsible for providing security guards or other security protection for all or any portion of the Premises or the Property, and Tenant shall at its own expense provide or obtain such security services as Tenant shall desire to ensure the safety of the Premises and the Property.

  • Office Visits (other than Preventive Care Services) This plan covers office and clinic visits to diagnose or treat a sickness or injury. Office visit copayments differ depending on the type of provider you see. This plan covers physician visits in your home if you have an injury or illness that: • confines you to your home; or • requires special transportation; and • because of this injury or illness, you are physically unable to travel to the provider’s

  • Configuration Management The Contractor shall maintain a configuration management program, which shall provide for the administrative and functional systems necessary for configuration identification, control, status accounting and reporting, to ensure configuration identity with the UCEU and associated cables produced by the Contractor. The Contractor shall maintain a Contractor approved Configuration Management Plan that complies with ANSI/EIA-649 2011. Notwithstanding ANSI/EIA-649 2011, the Contractor’s configuration management program shall comply with the VLS Configuration Management Plans, TL130-AD-PLN-010-VLS, and shall comply with the following:

  • RESPONSIBILITIES OF THE STATE 3.2.1 The State will identify a Project Manager for the Project. The Project Manager will be the sole point of contact between the Contractor and the State. The Project Manager will be the State’s representative authorized to communicate the State’s position and directions related to all contract work and to coordinate all change orders with the Commissioner of Buildings and General Services as deemed necessary. 3.2.2 If applicable, the State shall furnish all surveys describing the physical characteristics, legal limitations and utility locations for the site of the Project, and a legal description of the site. 3.2.3 Except as provided in Subparagraph 4.7.1, the State shall secure and pay for necessary approvals, easements, assessments and charges required for the construction, use or occupancy of permanent structures or for permanent changes in existing facilities. 3.2.4 Information or services under the State's control shall be furnished by the State with reasonable promptness to avoid delay in the orderly progress of the Work. 3.2.5 Unless otherwise provided in the Contract Documents, the Contractor will be furnished, free of charge, all copies of Drawings and Specifications reasonably necessary for the execution of the Work. 3.2.6 The State shall forward instructions to the Contractor through the Architect. 3.2.7 The foregoing are in addition to any other duties and responsibilities of the State enumerated in the Contract Documents including those responsibilities described in Articles 6, 9 and 11 of this agreement. 3.2.8 The State may utilize a Clerk-of-the-Works to provide inspection and monitoring work on behalf of the State. If a Clerk-of-the-Works is utilized, it is the responsibility of the Architect and the Contractor to review and understand the Clerk’s duties, responsibilities and limitations of authority. Upon request, the State shall provide a copy of the Clerk-of-the-Works contract to Architect and Contractor.

  • Heating, Ventilation and Air Conditioning Landlord shall furnish to the Premises heating, ventilation and air-conditioning (“HVAC”) in accordance with the Design Standards set forth in Exhibit D during Ordinary Business Hours. Landlord shall have access to all air-cooling, fan, ventilating and machine rooms and electrical closets and all other mechanical installations of Landlord (collectively, “Mechanical Installations”), and Tenant shall not construct partitions or other obstructions which may interfere with Landlord’s access thereto or the moving of Landlord’s equipment to and from the Mechanical Installations. No Tenant Party shall at any time enter the Mechanical Installations or tamper with, adjust, or otherwise affect such Mechanical Installations. Landlord shall not be responsible if the HVAC System fails to provide cooled or heated air, as the case may be, to the Premises in accordance with the Design Standards by reason of (i) any equipment installed by, for or on behalf of Tenant, which has an electrical load in excess of the average electrical load and human occupancy factors for the HVAC System as designed, or (ii) any rearrangement of partitioning or other Alterations made or performed by, for or on behalf of Tenant. Tenant shall install, if missing, blinds or shades on all windows, which blinds and shades shall be subject to Landlord’s approval, and shall keep operable windows in the Premises closed, and lower the blinds when necessary because of the sun’s position, whenever the HVAC System is in operation or as and when required by any Requirement. Tenant shall cooperate with Landlord and shall abide by the rules and regulations which Landlord may reasonably prescribe for the proper functioning and protection of the HVAC System. Tenant acknowledges that the server room in the Premises currently has three heat pumps installed, being two 4-ton units, and one 2.5-ton unit (the “Existing Heat Pumps”). The 2.5-ton unit is currently connected and operational. Tenant shall determine whether it is satisfied with the condition of the Existing Heat Pumps and Landlord shall not have any responsibility or liability for the condition, operation, maintenance, repair or replacement of the Existing Heat Pumps. Tenant may operate the Existing Heat Pumps. Tenant shall be responsible for, and pay directly for, all necessary maintenance and repairs to the Existing Heat Pumps. Tenant shall reimburse Landlord monthly for the cost of all utility services used to operate the Existing Heat Pumps within 10 Business Days after receipt of Landlord’s invoice for such amount. Landlord may measure Tenant’s usage of such utility services by either a sub-meter or by other reasonable methods such as by temporary check meters or by survey. Tenant, at its cost, may replace the Existing Heat Pumps with one or more new heat pumps, provided, however, that the capacity of such replacement heat pump(s) shall not exceed the 10.5-ton capacity cooling capacity of the Existing Heat Pumps.

  • Utilities and Appliances (1) The owner must provide all utilities needed to comply with the HQS. (2) The owner is not responsible for a breach of the HQS caused by the tenant’s failure to: (a) Pay for any utilities that are to be paid by the tenant. (b) Provide and maintain any appliances that are to be provided by the tenant.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!