Capacity and Efficiency Sample Clauses

Capacity and Efficiency. The unit shall have a continuous rated output of not less than 550 kVA at the terminals at a power factor of 0.8 percent (overexcited). The maximum temperature rise of the stator and rotor windings at rated output and normal conditions shall be 80ºC based on an ambient air temperature not exceeding 40ºC in accordance with ANSI standards. The unit shall be capable of operation over the following range of loadings for which the temperature rise in the stator and rotor windings shall not exceed 80ºC. - Generator outputs up to rated kVA continuously at voltages 5 percent above or below voltage for a range of power factors from 100 percent to 80 percent (overexcited) at 50-Hz system operation with a 40ºC ambient. - Guaranteed efficiency shall not be less than 95 % at Full Load of 0.8 power factor and 96% at Full Load of 1.0 power factor. - Bidder shall submit efficiency curves of generator together with the Bid.
AutoNDA by SimpleDocs

Related to Capacity and Efficiency

  • Energy Efficiency The contractor shall comply with all mandatory standards and policies relating to energy efficiency which are contained in the energy conservation plan issued in compliance with the Energy Policy and Conservation Act (Pub.L. 94-163) for the State in which the work under this contract is performed.

  • AGREEMENT FLEXIBILITY 7.1 Notwithstanding any other provision of this Agreement, an employer and an individual employee may agree to vary the application of certain terms of this agreement to meet the genuine individual needs of the employer and the individual employee. The terms the employer and the individual employee may agree to vary the application of are those concerning:

  • Workplace Flexibility Where, for bona fide operational reasons the Employer schedules employees to work Saturday or Sunday, the following criteria shall apply:

  • Human and Financial Resources to Implement Safeguards Requirements 6. The Borrower shall make available necessary budgetary and human resources to fully implement the EMP and the RP.

  • Flexibility (1) An employer and employee covered by this enterprise agreement may agree to make an individual flexibility arrangement to vary the effect of terms of the agreement if:

  • Operational Flexibility Each designated airline may, on any or all flights and at its option:

  • Alignment with Modernization Foundational Programs and Foundational Capabilities The activities and services that the LPHA has agreed to deliver under this Program Element align with Foundational Programs and Foundational Capabilities and the public health accountability metrics (if applicable), as follows (see Oregon’s Public Health Modernization Manual, (xxxx://xxx.xxxxxx.xxx/oha/PH/ABOUT/TASKFORCE/Documents/public_health_modernization_man ual.pdf):

  • Quality Assurance Requirements There are no special Quality Assurance requirements under this Agreement.

  • Contractor Responsibility and Debarment 14.1 A responsible contractor is a contractor who has demonstrated the attribute of trustworthiness, as well as quality, fitness, capacity and experience to satisfactorily perform the contract. It is the COUNTY’s policy to conduct business only with responsible contractors.

  • PRIME CONTRACTOR RESPONSIBILITY The contractor will be required to assume prime contractor responsibility for the contract and will be the sole point of contact with regard to all commodities, services and support. The prime contractor may delegate facilitation of contract orders to their “Authorized/Certified Dealers” only. This delegation will in no way relieve the contractor of any contractual obligations set forth in this Contract Award.

Time is Money Join Law Insider Premium to draft better contracts faster.