Co-Carrier Cross Connect (CCXC). 3.6.1 A CCXC is a cross connection between Neutral Tandem and another collocated telecommunications carrier, other than BellSouth, in the same BellSouth Premises. Where technically feasible, BellSouth will permit Neutral Tandem to interconnect between its Collocation Space(s) and the physical/virtual collocation space(s) of another collocated telecommunications carrier(s) within the same BellSouth Premises via a CCXC, pursuant to the FCC’s Rules. The other collocated telecommunications carrier’s agreement must also contain CCXC rates, terms and conditions before BellSouth will permit the provisioning of a CCXC between the two (2) collocated carriers. The applicable BellSouth charges will be assessed to Neutral Tandem upon Neutral Tandem’s request for the CCXC. Neutral Tandem is prohibited from using the Collocation Space for the sole or primary purpose of cross-connecting to other collocated telecommunications carriers. 3.6.2 Neutral Tandem must contract with a BellSouth Certified Supplier to place the CCXC. The CCXC shall be provisioned using facilities owned by Neutral Tandem. Such cross-connections to other collocated telecommunications carriers may be made using either electrical or optical facilities. Neutral Tandem shall be responsible for providing a LOA, with the application, to BellSouth from the other collocated telecommunications carrier to which it will be cross-connecting. The CCXC shall utilize BellSouth common cable support structure. There will be a recurring charge per linear foot, per cable, of the common cable support structure used by Neutral Tandem to provision the CCXC to the other collocated telecommunications carrier. In those instances where Neutral Tandem’s equipment and the equipment of the other collocated telecommunications carrier are located in contiguous caged Collocation Space, Neutral Tandem may use its own technicians to install the CCXC using either electrical or optical facilities between the equipment of both collocated telecommunications carriers by constructing a dedicated cable support structure between the two (2) contiguous cages. Neutral Tandem shall deploy such electrical or optical cross-connections directly between its own equipment and the equipment of the other collocated telecommunications carrier without being routed through BellSouth’s equipment or, in the case of a CCXC provisioned between contiguous collocation spaces, common cable support structure. Neutral Tandem shall not provision CCXC on any BellSo...
AutoNDA by SimpleDocs
Co-Carrier Cross Connect (CCXC). 3.6.1 A CCXC is a cross connection between ACCESS Integrated and another collocated telecommunications carrier, other than BellSouth, in the same BellSouth Premises. Where technically feasible, BellSouth will permit ACCESS Integrated to interconnect between its Collocation Space(s) and the physical/virtual collocation space(s) of another collocated telecommunications carrier(s) within the same BellSouth Premises via a CCXC, pursuant to the FCC’s Rules. The other collocated telecommunications carrier’s agreement must also contain CCXC rates, terms and conditions before BellSouth will permit the provisioning of a CCXC between the two (2) collocated carriers. The applicable BellSouth charges will be assessed to ACCESS Integrated upon ACCESS Integrated’s request for the CCXC. ACCESS Integrated is prohibited from using the Collocation Space for the sole or primary purpose of cross-connecting to other collocated telecommunications carriers.
Co-Carrier Cross Connect (CCXC). The primary purpose of collocating CLEC equipment is to interconnect with BellSouth's network for the provision of telecommunications services. BellSouth will permit T-Mobile to interconnect between its virtual or physical collocation arrangements and those of another collocated telecommunications carrier within the same central office. Both telecommunications carriers’ Agreements must contain rates, terms and conditions for CCXC language. At no point in time shall T-Mobile use the Collocation Space for the sole or primary purpose of cross connecting to other telecommunications carriers.
Co-Carrier Cross Connect (CCXC). The primary purpose of collocation is for a collocated telecommunications carrier to interconnect with BellSouth’s network or to access BellSouth’s unbundled network elements for the provision of telecommunications services within a BellSouth Premises. BellSouth will permit DeltaCom to interconnect between its virtual or physical collocation arrangements and those of another collocated telecommunications carrier within the same central office. Both DeltaCom’s agreement and the other collocated telecommunications carrier’s agreement must contain rates, terms and conditions for CCXC language. At no point in time shall DeltaCom use the Collocation Space for the sole or primary purpose of cross connecting to other collocated telecommunications carriers. DeltaCom, if certified as a BellSouth Certified Supplier, or its BellSouth Certified Supplier must place the CCXC. The CCXC shall be provisioned through facilities owned by DeltaCom.

Related to Co-Carrier Cross Connect (CCXC)

  • Verizon OSS Services 8.2.1 Upon request by ECI, Verizon shall provide to ECI Verizon OSS Services. Such Verizon OSS Services will be provided in accordance with, but only to the extent required by, Applicable Law. 8.2.2 Subject to the requirements of Applicable Law, Verizon Operations Support Systems, Verizon Operations Support Systems functions, Verizon OSS Facilities, Verizon OSS Information, and the Verizon OSS Services that will be offered by Verizon, shall be as determined by Verizon. Subject to the requirements of Applicable Law, Verizon shall have the right to change Verizon Operations Support Systems, Verizon Operations Support Systems functions, Verizon OSS Facilities, Verizon OSS Information, and the Verizon OSS Services, from time-to-time, without the consent of ECI. 8.2.3 To the extent required by Applicable Law, in providing Verizon OSS Services to ECI, Verizon will comply with Verizon’s applicable OSS Change Management Guidelines, as such Guidelines are modified from time-to-time, including, but not limited to, the provisions of the Guidelines related to furnishing notice of changes in Verizon OSS Services. Verizon’s OSS Change Management Guidelines will be set out on a Verizon website.

  • Network Services Local Access Services In lieu of any other rates and discounts, Customer will pay fixed monthly recurring local loop charges ranging from $1,200 to $2,000 for TDM-based DS-3 Network Services Local Access Services at 2 CLLI codes mutually agreed upon by Customer and Company.

  • Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Xxxx has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Xxxx. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Xxxx (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Xxxx, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Xxxx will then have the option of paying the one-time SC rates to place the Loop.

  • Data shared with Subcontractors If DSHS Data provided under this Contract is to be shared with a subcontractor, the Contract with the subcontractor must include all of the data security provisions within this Contract and within any amendments, attachments, or exhibits within this Contract. If the Contractor cannot protect the Data as articulated within this Contract, then the contract with the sub- Contractor must be submitted to the DSHS Contact specified for this contract for review and approval.

  • Third Party Vendors Nothing herein shall impose any duty upon DST in connection with or make DST liable for the actions or omissions to act of the following types of unaffiliated third parties: (a) courier and mail services including but not limited to Airborne Services, Federal Express, UPS and the U.S. Mails, (b) telecommunications companies including but not limited to AT&T, Sprint, MCI and other delivery, telecommunications and other such companies not under the party’s reasonable control, and (c) third parties not under the party’s reasonable control or subcontract relationship providing services to the financial industry generally, such as, by way of example and not limitation, the National Securities Clearing Corporation (processing and settlement services), Fund custodian banks (custody and fund accounting services) and administrators (blue sky and Fund administration services), and national database providers such as Choice Point, Acxiom, TransUnion or Lexis/Nexis and any replacements thereof or similar entities, provided, if DST selected such company, DST shall have exercised due care in selecting the same. Such third party vendors shall not be deemed, and are not, subcontractors for purposes of this Agreement.

  • Verizon Operations Support Systems Verizon systems for pre- ordering, ordering, provisioning, maintenance and repair, and billing.

  • Interconnection Customer Authority Consistent with Good Utility Practice, this LGIA, and the CAISO Tariff, the Interconnection Customer may take actions or inactions with regard to the Large Generating Facility or the Interconnection Customer’s Interconnection Facilities during an Emergency Condition in order to (i) preserve public health and safety, (ii) preserve the reliability of the Large Generating Facility or the Interconnection Customer’s Interconnection Facilities,

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CSTC chooses to subtend a Verizon access Tandem, CSTC’s NPA/NXX must be assigned by CSTC to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG. 9.2.2 CSTC shall establish Access Toll Connecting Trunks pursuant to applicable access Tariffs by which it will provide Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic to and from CSTC’s Customers. 9.2.3 The Access Toll Connecting Trunks shall be two-way trunks. Such trunks shall connect the End Office CSTC utilizes to provide Telephone Exchange Service and Switched Exchange Access to its Customers in a given LATA to the access Tandem(s) Verizon utilizes to provide Exchange Access in such LATA. 9.2.4 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access to allow CSTC’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier which is connected to a Verizon access Tandem.

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at a P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • The Web Services E-Verify Employer Agent agrees to, consistent with applicable laws, regulations, and policies, commit sufficient personnel and resources to meet the requirements of this MOU.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!