Technical Requirements 4.5.3.1 Tandem Switching shall have the same capabilities or equivalent capabilities as those described in Telcordia TR-TSY-000540 Issue 2R2, Tandem Supplement, June 1, 1990. The requirements for Tandem Switching include but are not limited to the following: 4.5.3.1.1 Tandem Switching shall provide signaling to establish a tandem connection; 4.5.3.1.2 Tandem Switching will provide screening as jointly agreed to by <<customer_short_name>> and BellSouth; 4.5.3.1.3 Where applicable, Tandem Switching shall provide AIN triggers supporting AIN features where such routing is not available from the originating end office switch, to the extent such Tandem switch has such capability; 4.5.3.1.4 Where applicable, Tandem Switching shall provide access to Toll Free number database; 4.5.3.1.5 Tandem Switching shall provide connectivity to Public Safety Answering Point (PSAP)s where 911 solutions are deployed and the tandem is used for 911; and 4.5.3.1.6 Where appropriate, Tandem Switching shall provide connectivity for the purpose of routing transit traffic to and from other carriers. 4.5.3.2 BellSouth may perform testing and fault isolation on the underlying switch that is providing Tandem Switching. Such testing shall be testing routinely performed by BellSouth. The results and reports of the testing shall be made available to <<customer_short_name>>. 4.5.3.3 BellSouth shall control congestion points and network abnormalities. All traffic will be restricted in a non-discriminatory manner. 4.5.3.4 Tandem Switching shall process originating toll free traffic received from <<customer_short_name>>’s local switch. 4.5.3.5 In support of AIN triggers and features, Tandem Switching shall provide SSP capabilities when these capabilities are not available from the Local Switching Network Element to the extent such Tandem Switch has such capability.
Standards Compliance Registry Operator shall comply with relevant existing RFCs and those published in the future by the Internet Engineering Task Force (IETF), including all successor standards, modifications or additions thereto relating to the DNS and name server operations including without limitation RFCs 1034, 1035, 1123, 1982, 2181, 2182, 2671, 3226, 3596, 3597, 4343, and 5966. DNS labels may only include hyphens in the third and fourth position if they represent valid IDNs (as specified above) in their ASCII encoding (e.g., “xn--ndk061n”).
Compliance Requirements A. Nondiscrimination. The Contractor agrees to comply, and to require its subcontractor(s) to comply, with the nondiscrimination provisions of MCL 37.2209. The Contractor further agrees to comply with the provisions of Section 9:158 of Chapter 112 of the Xxx Arbor City Code and to assure that applicants are employed and that employees are treated during employment in a manner which provides equal employment opportunity.
CONTRACT COMPLIANCE REQUIREMENT The HUB requirement on this Contract is 0%. The student engagement requirement of this Contract is 0 hours. The Career Education requirement for this Contract is 0 hours. Failure to achieve these requirements may result in the application of some or all of the sanctions set forth in Administrative Policy 3.10, which is hereby incorporated by reference.
Compliance with Regulatory Requirements Upon demand by Lender, Borrower shall reimburse Lender for Lender’s additional costs and/or reductions in the amount of principal or interest received or receivable by Lender if at any time after the date of this Agreement any law, treaty or regulation or any change in any law, treaty or regulation or the interpretation thereof by any Governmental Authority charged with the administration thereof or any other authority having jurisdiction over Lender or the Loans, whether or not having the force of law, shall impose, modify or deem applicable any reserve and/or special deposit requirement against or in respect of assets held by or deposits in or for the account of the Loans by Lender or impose on Lender any other condition with respect to this Agreement or the Loans, the result of which is to either increase the cost to Lender of making or maintaining the Loans or to reduce the amount of principal or interest received or receivable by Lender with respect to such Loans. Said additional costs and/or reductions will be those which directly result from the imposition of such requirement or condition on the making or maintaining of such Loans.
Child Abuse Reporting Requirements A. Grantees shall comply with child abuse and neglect reporting requirements in Texas Family Code Chapter 261. This section is in addition to and does not supersede any other legal obligation of the Grantee to report child abuse. B. Grantee shall use the Texas Abuse Hotline Website located at xxxxx://xxx.xxxxxxxxxxxxxx.xxx/Login/Default.aspx as required by the System Agency. Grantee shall retain reporting documentation on site and make it available for inspection by the System Agency.
Quality Assurance Requirements There are no special Quality Assurance requirements under this Agreement.
Compliance with Accessibility Standards All parties to this Agreement shall ensure that the plans for and the construction of all projects subject to this Agreement are in compliance with standards issued or approved by the Texas Department of Licensing and Regulation (TDLR) as meeting or consistent with minimum accessibility requirements of the Americans with Disabilities Act (P.L. 101-336) (ADA).
Compliance Reporting a. Provide reports to the Securities and Exchange Commission, the National Association of Securities Dealers and the States in which the Fund is registered. b. Prepare and distribute appropriate Internal Revenue Service forms for corresponding Fund and shareholder income and capital gains. c. Issue tax withholding reports to the Internal Revenue Service.
System Requirements Apple Software is supported only on Apple-branded hardware that meets specified system requirements as indicated by Apple.