Criteria for Determining Capacity of Transportation Facilities Sample Clauses

Criteria for Determining Capacity of Transportation Facilities. Subject to Article 45, the State shall design and construct the project transportation facilities so as to provide in each reach thereof, including reservoirs, the capacity necessary to enable delivery of project water in each year to the Agency and to other contractors in the maximum monthly amounts and at the locations, times, and maximum rates specified or provided for in their respective contracts for such year, and shall include in each such reach such capacity as is economically justified in the judgment of the State to compensate for scheduled outages for purposes of necessary investigation, inspection, maintenance, repair or replacement of project facilities, and for losses of water due to evaporation, leakage, seepage, or other causes: Provided, That regulatory storage reservoirs included in the project transportation facilities may be utilized in conjunction with conveyance capacity provided in said facilities for delivery to the Agency of the foregoing monthly amounts.
AutoNDA by SimpleDocs
Criteria for Determining Capacity of Transportation Facilities. > The State shall design and construct the project transportation facilities so as to provide for each reach thereof, including reservoirs, the capacity necessary to enable delivery of project water in each year to the District and to other contractors in the maximum monthly amounts and at the locations, times, and maximum rates specified or provided for in their respective contracts for such year, and shall include in each such reach such capacity as is economically justified in the judgment of the State to compensate for scheduled outages for purposes of necessary investigation, inspection, maintenance, repair or replacement of project facilities, and for losses of water due to evaporation, leakage, seepage, or other causes. Subject to Articles 6(b), 7(b), 12(b), and 12(c), the capacity so to be provided by the State for each reach of the project transportation facilities necessary for transporting water to the District shall be sufficient to enable delivery to the District in each month of any year of an amount of water up to but not exceeding eleven percent (11%) of the District’s annual entitlement for the respective year and, upon completion of the project facilities, to enable delivery to the District in each month of any year of an amount of water up to but not exceeding eleven percent (11%) of the District’s maximum annual entitlement: Provided, That regulatory storage reservoirs included in the project transportation facilities may be utilized in conjunction with conveyance capacity provided in said facilities for delivery to the District of the foregoing monthly amounts, subject to the retention at all times, except during periods of emergency, in each reservoir on the East Branch Aqueduct and the West Branch Aqueduct, respectively, of an amount of stored water reasonably sufficient to meet emergency requirements of the District for project water during the respective year: Provided further, That excess capacity shall be provided in accordance with Article 47(c) of this contract.
Criteria for Determining Capacity of Transportation Facilities. Subject to Article 45, the State shall design and construct the project transportation facilities so as to provide in each reach thereof, including reservoirs, the capacity necessary to 29 Amended: Amendment 3 enable delivery of project water in each year to the Agency and to other contractors in the maximum monthly amounts and at the locations, times, and maximum rates specified or provided for in their respective contracts for such year, and shall include in each such reach such capacity as is economically justified in the judgment of the State to compensate for scheduled outages for purposes of necessary investigation, inspection, maintenance, repair or replacement of project facilities, and for losses of water due to evaporation, leakage, seepage, or other causes: Provided, That regulatory storage reservoirs included in the project transportation facilities may be utilized in conjunction with conveyance capacity provided in said facilities for delivery to the Agency of the foregoing monthly amounts: Provided further, That excess capacity shall be provided in accordance with Article 45(d) of this contract.

Related to Criteria for Determining Capacity of Transportation Facilities

  • Cost Responsibility for Interconnection Facilities and Distribution Upgrades 4.1 Interconnection Facilities 4.2 Distribution Upgrades

  • Interconnection Facility Options The Intercarrier Compensation provisions of this Agreement shall apply to the exchange of Exchange Service (EAS/Local) traffic between CLEC's network and Qwest's network. Where either Party acts as an IntraLATA Toll provider, each Party shall xxxx the other the appropriate charges pursuant to its respective tariff or price lists. Where either Party interconnects and delivers traffic to the other from third parties, each Party shall xxxx such third parties the appropriate charges pursuant to its respective tariffs, price lists or contractual offerings for such third party terminations. Absent a separately negotiated agreement to the contrary, the Parties will directly exchange traffic between their respective networks without the use of third party transit providers.

  • Interconnection Customer’s Interconnection Facilities Construction The Interconnection Customer’s Interconnection Facilities shall be designed and constructed in accordance with Good Utility Practice. Within one hundred twenty (120) Calendar Days after the Commercial Operation Date, unless the Participating TO and Interconnection Customer agree on another mutually acceptable deadline, the Interconnection Customer shall deliver to the Participating TO and CAISO “as-built” drawings, information and documents for the Interconnection Customer’s Interconnection Facilities and the Electric Generating Unit(s), such as: a one-line diagram, a site plan showing the Large Generating Facility and the Interconnection Customer’s Interconnection Facilities, plan and elevation drawings showing the layout of the Interconnection Customer’s Interconnection Facilities, a relay functional diagram, relaying AC and DC schematic wiring diagrams and relay settings for all facilities associated with the Interconnection Customer's step-up transformers, the facilities connecting the Large Generating Facility to the step-up transformers and the Interconnection Customer’s Interconnection Facilities, and the impedances (determined by factory tests) for the associated step-up transformers and the Electric Generating Units. The Interconnection Customer shall provide the Participating TO and the CAISO specifications for the excitation system, automatic voltage regulator, Large Generating Facility control and protection settings, transformer tap settings, and communications, if applicable. Any deviations from the relay settings, machine specifications, and other specifications originally submitted by the Interconnection Customer shall be assessed by the Participating TO and the CAISO pursuant to the appropriate provisions of this LGIA and the LGIP.

  • Interconnection Facilities 4.1.1 The Interconnection Customer shall pay for the cost of the Interconnection Facilities itemized in Attachment 2 of this Agreement. The NYISO, in consultation with the Connecting Transmission Owner, shall provide a best estimate cost, including overheads, for the purchase and construction of its Interconnection Facilities and provide a detailed itemization of such costs. Costs associated with Interconnection Facilities may be shared with other entities that may benefit from such facilities by agreement of the Interconnection Customer, such other entities, the NYISO, and the Connecting Transmission Owner.

  • Purpose of Interconnection Facilities Except as may be required by Applicable Laws and Regulations, or as otherwise agreed to among the Parties, the Interconnection Facilities shall be constructed for the sole purpose of interconnecting the Large Generating Facility to the Participating TO’s Transmission System and shall be used for no other purpose.

  • Information regarding Interconnection Facilities 4.2.1 The SPD shall be required to obtain all information from the STU/CTU/concerned authority with regard to the Interconnection Facilities as is reasonably necessary to enable it to design, install and operate all interconnection plant and apparatus on the SPD’s side of the Delivery Point to enable delivery of electricity at the Delivery Point. The transmission of power up to the point of interconnection where the metering is done for energy accounting shall be the responsibility of the SPD at his own cost.

  • Interconnection Customer’s Interconnection Facilities The Interconnection Customer shall design, procure, construct, install, own and/or control the Interconnection Customer’s Interconnection Facilities described in Appendix A at its sole expense.

  • Fire, Life Safety, and Accessibility Codes The following codes, in the versions approved by the Georgia State Fire Marshal/Fire Safety Commissioner and Department of Human Resources, shall be used. The Design Professional will designate any additional codes or special modifications in the Supplementary General Conditions.

  • Interconnection Customer Interconnection Facilities Interconnection Customer shall design, procure, construct, install, own and/or control Interconnection Customer Interconnection Facilities described in Appendix A, Interconnection Facilities, Network Upgrades and Distribution Upgrades, at its sole expense.

  • Reactive Power and Primary Frequency Response 9.6.1 Power Factor Design Criteria

Time is Money Join Law Insider Premium to draft better contracts faster.