DAMPPROOFING OF WALLS AND FLOORS One Sample Clauses

DAMPPROOFING OF WALLS AND FLOORS One layer of 350 micron 'USB GREEN' waterproof sheeting sealed at laps with 'Gunplas Pressure Sensitive Tape': 1 Under surface beds. m2 151 A1 : 48 A2 : 47 A3 : 56 One layer of 350 micron embossed dampcourse waterproof sheeting below walls, sills, etc: 2 Below walls, sills, etc. m2 22 A1 : 8 A2 : 7 A3 : 7 Carried to Collection Section 2 Bill No. 4 Waterproofing JOINT SEALANTS ETC Clear Neutral silicone sealant: 3 In joint sealing and pointing all round external window and door frames. A1 : 32 A2 : 28 A3 : 40 Two-part grey polysulphide sealing compound including backing cord, bond breaker, primer, etc
AutoNDA by SimpleDocs
DAMPPROOFING OF WALLS AND FLOORS One layer of 350 micron 'USB GREEN' waterproof sheeting sealed at laps with 'Gunplas Pressure Sensitive Tape': 1 Under surface beds. m2 172 A1 : 48 A2 : 39 A3 : 38 A4 : 47 One layer of 350 micron embossed dampcourse waterproof sheeting below walls, sills, etc: 2 Below walls, sills, etc. m2 26 A1 : 8 A2 : 6 A3 : 6 A4 : 6 Carried to Collection Section 2 Bill No. 4 Waterproofing
DAMPPROOFING OF WALLS AND FLOORS One layer approved 375 micron embossed black polyethylene damp proof course In walls m2 Under window cills m2 One layer 250 micron green polyethylene waterproof sheeting complying with SABS 952 Type C in widest practicable widths with all joints lapped and sealed with pressure sensitive tape all in strict accordance with the manufacturer's requirements Under surface beds m2 Carried Forward to Summary of Section No. 2 Bill No. 4 WATERPROOFING Quantity 52 20 400 Rate R Amount
DAMPPROOFING OF WALLS AND FLOORS One layer of 350 micron 'USB GREEN' waterproof sheeting sealed at laps with 'Gunplas Pressure Sensitive Tape': 1 Under surface beds. m2 241 A1 : 52 A2 : 78 A3 : 55 A4 : 56 One layer of 350 micron embossed dampcourse waterproof sheeting below walls, sills, etc: 2 Below walls, sills, etc. m2 37 A1 : 8 A2 : 14 A3 : 7 A4 : 8 Carried to Collection Section 2 Bill No. 4 Waterproofing JOINT SEALANTS ETC Clear Neutral silicone sealant: 3 In joint sealing and pointing all round external window and door frames. A1 : 37 A2 : 46 A3 : 40 A4 : 37 Two-part grey polysulphide sealing compound including backing cord, bond breaker, primer, etc

Related to DAMPPROOFING OF WALLS AND FLOORS One

  • Staging In addition to the staging categories listed in paragraph 1 of Annex 2-A, this Schedule contains staging categories 20-A, 20-B, PR-1 and PR-130:

  • Carpet Cleaning Shampooing carpets with the deep dirt extraction (steam cleaning) method per manufactures recommendations.

  • Dry Cleaning Timpson have over 520 dry cleaning stores and are now the UK’s biggest family-run dry cleaner. We process and clean up to 40,000 garments per week and have 32 Dry Cleaning production sites located around the UK. 19 of these sites are Timpson Super Hubs and act as satellite production centres. We offer customers a next day service on everyday items and quality check each garment before it leaves production. Dry Cleaning by Timpson See prices, opening times and more about dry cleaning and laundry services in , . From £2 per item. : Dry cleaning & laundry services DLS have the expertise to advise, design, supply, install & maintain your professional laundry equipment

  • Drainage Systems (1) Clear culvert inlets, outlets, and sediment catching basins.

  • Building Commissioning Services The Owner may provide as a part of its testing services the Building Commissioning services involving the project’s HVAC and exhaust systems, temperature control systems, fire detection and alarm systems, emergency power and lighting system, fire suppression system, security locks and security locking control systems, food service equipment (if applicable), and laundry equipment (if applicable). In the event the Using Agency’s Program specifies additional commissioning services, the Owner shall procure such services as well. The Owner, through its Executive Administrator, may engage an independent Commissioning Authority. It is the intent of this Article that the Commissioning Authority enforce the requirements mentioned herein and certify that the systems and equipment listed all function properly prior to the initiation of each final inspection.

  • Road Surfaces (1) Grade, shape, crown, and/or outslope surface and shoulders.

  • Exterior Drainage Does water stand on the property for more than 24 hours after a heavy rain? Yes No Unknown Comments Are gutters and downspouts in good repair? Yes No Unknown Comments:

  • Electrical Safety Only UL approved items are permitted in Housing & Residence Life. Extension and multi-use cords must be heavy duty, single plug, and be UL approved. Altering or adapting electrical outlets and equipment and overloading circuits jeopardize safety and thus are not permitted.

  • Electrical appliance safety The Hirer shall ensure that any electrical appliances brought by them to the premises and used there shall be safe, in good working order, and used in a safe manner in accordance with the Electricity at Work Regulations 1989. Where a residual circuit breaker is provided the hirer must make use of it in the interests of public safety.

  • Cutting and Patching The Contractor shall be responsible for cutting, fitting or patching required to complete the Work or to make its parts fit together properly.