Dimensional Conformity. Part dimensions must conform to the specified tolerances in conformance with the dimensional design specifications. No deviation from the specifications is allowed without an Engineering Change Order (ECO) or a Temporary Process Deviation (“TPD”). Tolerances are given based on a dimension datum. Examples of datum are shown in figure 1. Refer to table below for Tolerance. [***] No cracking, flash, or damages from insertion process are allowed in the boss area.
AutoNDA by SimpleDocs
Dimensional Conformity. Part dimensions must conform to the specified tolerances in conformance with the dimensional design specifications. No deviation from the specifications is allowed without an Engineering Change Order (ECO) or a Temporary Process Deviation (TPD). Tolerances are given based on a dimension datum. Examples of datum are shown in figure 1. Refer to table below for Tolerance. [***] Title: Workmanship Standards Mechanical Assemblies and Parts Sheet: 8 Of 17 Number: 263 - 00352 Rev: D0 No cracking, flash, or damages from insertion process are allowed in the boss area.

Related to Dimensional Conformity

  • Technical Specifications Each Bloom System is an integrated system comprised of a fuel cell stack assembly and associated balance of plant components that converts a fuel into electricity using electrochemical means that (i) has a Nameplate Capacity of at least 0.5 kilowatts of electricity using an electrochemical process and (ii) has an electricity-only generation efficiency greater than thirty percent (30%).

  • Specification Changes (a) During the Term, GSK will accept a labeling change from Prometheus as contemplated by this Section 4.2 but otherwise the Parties acknowledge and agree that GSK does not intend to make any material changes (such as packaging design, manufacturing process or similar or related changes) to the existing Product during the Term.

  • Quality Specifications SANMINA-SCI shall comply with the quality specifications set forth in its Quality Manual, incorporated by reference herein, a copy of which is available from SANMINA-SCI upon request.

  • Plans and Specifications Tenant shall be solely responsible for the preparation of the final architectural, electrical and mechanical construction drawings, plans and specifications (called “plans”) necessary for Tenant to construct the Premises for Tenant’s occupancy, which plans shall be subject to approval by Landlord’s architect and engineers and shall comply with their reasonable requirements to avoid aesthetic or other conflicts with the design and function of the balance of the Building. Landlord’s approval is solely given for the benefit of Landlord, and neither Tenant nor any third party shall have the right to rely upon Landlord’s approval of Tenant’s plans for any purpose whatsoever other than that Landlord does not object thereto under this Lease. Landlord’s architects and engineers shall respond (with approval or disapproval) to any plan submission by Tenant within 8 business days after Landlord’s receipt thereof. If Landlord fails to respond to any such submission within such 8 business day period, which failure continues for more than 2 business days after Tenant gives Landlord a written notice (the “Deemed Approved Notice”) advising Landlord that such plan submission shall be deemed approved within 2 business days of Landlord’s receipt of the Deemed Approved Notice, then such plan submission shall be deemed approved hereunder. The Deemed Approved Notice shall, in order to be effective, contain on the first page thereof, in a font at least twice as large as the font of any other text contained in such notice, a legend substantially as follows: “FAILURE TO RESPOND TO THIS NOTICE WITHIN TWO (2) BUSINESS DAYS AFTER RECEIPT HEREOF SHALL CONSTITUTE LANDLORD’S APPROVAL OF SUBMITTED PLANS.” In the event Landlord’s architect’s or engineers’ approval of Tenant’s plans is withheld or conditioned, Landlord shall send prompt written notification thereof to Tenant and include a reasonably detailed statement identifying the reasons for such refusal or condition, and Tenant shall promptly have the plans revised by its architect to incorporate all reasonable objections and conditions presented by Landlord and shall resubmit such plans to Landlord. Landlord’s architects and engineers shall respond (with approval or disapproval) to any plan re-submission by Tenant within 8 business days after Landlord’s receipt thereof. Such process shall be followed until the plans shall have been approved by Landlord’s architect and engineers without unreasonable objection or condition. Without limiting the foregoing, Tenant shall be responsible for all elements of the design of Tenant’s plans (including, without limitation, compliance with law, functionality of design, the structural integrity of the design, the configuration of the Premises and the placement of Tenant’s furniture, appliances and equipment), and Landlord’s approval of Tenant’s plans shall in no event relieve Tenant of the responsibility for such design. Tenant agrees it shall be solely responsible for the timely preparation and submission of all such plans and for all elements of the design of such plans and for all costs related thereto. (The word “architect” as used in this Section 3.2 shall include an interior designer or space planner.) Tenant shall reimburse Landlord Landlord’s reasonable out-of-pocket expense incurred in connection with the review of Tenant’s plans.

  • Configuration The configuration for the Purchase Right Aircraft will be the Detail Specification for Model 767-3S2F aircraft at the revision level in effect at the time of the Supplemental Agreement. Such Detail Specification will be revised to include (i) changes required to obtain required regulatory certificates and (ii) other changes as mutually agreed upon by Boeing and Customer.

  • Deviations A written authorization, granted after contract award and prior to the manufacture of the item, to depart from a particular performance or design requirement of a contract, specification, or referenced document, for a specific number of units or a specified period of time. Deviations are intended only as one-time departures from an established configuration for specified items or lots and are not intended to be repeatedly used in place of formal engineering changes. BATC shall devise a system to control, monitor, and notify DigitalGlobe of these changes. The control system shall include provision for:

  • Computational Materials and Structural Term Sheets (a) Not later than 10:30 a.m., New York time, on the business day before the date on which the Current Report relating to the Offered Certificates of a Series is required to be filed by the Company with the Commission pursuant to Section 5(b) hereof, the Underwriter shall deliver to the Company five complete copies of all materials provided by the Underwriter to prospective investors in such Offered Certificates that constitute (i) "Computational Materials" within the meaning of the no-action letter dated May 20, 1994 issued by the Division of Corporation Finance of the Commission to Xxxxxx, Xxxxxxx Acceptance Corporation I, Xxxxxx, Peabody & Co. Incorporated, and Xxxxxx Structured Asset Corporation and the no-action letter dated May 27, 1994 issued by the Division of Corporation Finance of the Commission to the Public Securities Association (together, the "Xxxxxx Letters"), the filing of which material is a condition of the relief granted in such letter (such materials being the "Computational Materials"), and (ii) "Structural Term Sheets" within the meaning of the no-action letter dated February 17, 1995 issued by the Division of Corporation Finance of the Commission to the Public Securities Association (the "PSA Letter"), the filing of which material is a condition of the relief granted in such letter (such materials being the "Structural Term Sheets"). Each delivery of Computational Materials and Structural Term Sheets to the Company pursuant to this paragraph (a) shall be effected by delivering four copies of such materials to counsel for the Company on behalf of the Company at the address specified in Section 3 hereof and one copy of such materials to the Company.

  • Delivery Schedule The scheduled months of delivery of the Aircraft are listed in the attached Table 1. Exhibit B describes certain responsibilities for both Customer and Boeing in order to accomplish the delivery of the Aircraft.

  • Certificate of Analysis Seller shall provide a certificate of analysis and other documents as defined in the Quality Agreement for any Product to be released hereunder, in a form in accordance with the cGMPs and all other applicable Regulatory Requirements and Product Specifications and as shall be agreed upon by the parties. For any batch that initially failed to meet any Product Specification, the certificate of analysis shall document the exception. Products that do not meet dissolution specifications at USP Stage I and II testing shall not be accepted by Buyer (and such requirement shall be included in the Product Specifications/Quality Manual).

  • Changes to Specifications All Specifications and any changes thereto agreed to by the parties from time to time shall be in writing, dated and signed by the parties. Any change to the Process shall be deemed a Specification change. No change in the Specifications shall be implemented by Catalent, whether requested by Client or requested or required by any Regulatory Authority, until the parties have agreed in writing to such change, the implementation date of such change, and any increase or decrease in costs, expenses or fees associated with such change (including any change to Unit Pricing). Catalent shall respond promptly to any request made by Client for a change in the Specifications, and both parties shall use commercially reasonable, good faith efforts to agree to the terms of such change in a timely manner. As soon as possible after a request is made for any change in Specifications, Catalent shall notify Client of the costs associated with such change and shall provide such supporting documentation as Client may reasonably require. Client shall pay all costs associated with such agreed upon changes. If there is a conflict between the terms of this Agreement and the terms of the Specifications, this Agreement shall control. Catalent reserves the right to postpone effecting changes to the Specifications until such time as the parties agree to and execute the required written amendment.