Duties and Weekly Work Schedules for Reassigned Faculty Sample Clauses

Duties and Weekly Work Schedules for Reassigned Faculty. Appropriate duties and weekly work schedules are determined by the college administration in concert with the faculty member reassigned, consistent with the number of weekly hours assigned to such duties, and in accordance with the relevant workload tables.
AutoNDA by SimpleDocs

Related to Duties and Weekly Work Schedules for Reassigned Faculty

  • JOB DUTIES AND TASKS 1. Ensures maintenance and repair of Commission's properties by maintenance crews and performs maintenance and repair duties (a) Directs maintenance staff (and grounds staff in Prince Rupert) in the completion of duties related to the maintenance and repair of Commission properties; (b) Organizes and schedules crews; ensuring work standards and deadlines are met; (c) Completes performance evaluation of staff; recommends disciplinary or other appropriate action where necessary; and other related supervisory duties as required; (d) Carries out electrical, plumbing and carpentry repairs and maintenance as listed on Maintenance Worker I such as repair/replace ballasts, fans, breakers and electrical fixtures, repair/replace plumbing fixtures, water lines and piping; repair gyproc walls and repair rollers on sliding doors and windows; (e) Carries out exterior repairs such as repairing roof leaks and flashing, cleaning gutters and replacing locks, railings, window and door closers and weather stripping; (f) Maintains own inventory of tools as listed in Appendix B, Part III; (g) Operates Employer's vehicle including trailers to load and unload tools, materials and/or equipment and/or Employer's assets; (h) Performs routine repairs and maintenance to appliances and equipment; (i) Performs routine repairs and maintenance to HVAC equipment; (j) Redirects contractors where minor deviations in the performance of work specifications are noted and reports on major deviations in contract performance on modernization and improvement delivery programs; (k) Performs work that requires adherence to safety procedures/practices when dealing with hazards; (l) May be required to utilize tact and diplomacy and refer tenants to other staff where appropriate. In some occasions may be required to exercise interpersonal and conflict resolution skills when dealing with tenants with complex health and social issues when other resources are not available. 2. Maintains inventory, records and standards (a) Maintains records related to work orders, chargebacks, preventive maintenance programs, and inventory; (b) Assists in the estimating and ordering of materials.

  • CONTRACTOR DUTIES 5.1 The Contractor will perform the following duties in regard to any student data it obtains:

  • SCOPE OF WORK AND RESPONSIBILITIES 1. Interconnection Customer’s Scope of Work and Responsibilities The Interconnection Customer will design, construct, own, operate and maintain the Interconnection Customer’s Interconnection Facilities and Collection Feeder Lines in accordance with the following requirements, to the extent not inconsistent with the terms of this Agreement, the ISO OATT or applicable NYISO Procedures: NYISO requirements, industry standards and specifications, regulatory requirements, the Connecting Transmission Owner’s applicable Connecting Transmission Owner’s Electric System Bulletins (“ESBs”), provided at the following website: xxxxx://xxx.xxxxxxxxxxxxxx.xxx/ProNet/Technical-Resources/Electric- Specifications, the System Protection and Interconnection Customer Attachment Facilities Electric Installation Specification for Xxxxxxxxx Solar Project provided as Appendix C to the Facilities Study for the Small Generating Facility (“Project Specific Specifications”), as such specifications shall be modified as a result of the Interconnection Customer’s post Facilities SERVICE AGREEMENT NO. 2557 Study modifications to the Interconnection Customer’s Interconnection Facilities, and Good Utility Practice. The Interconnection Customer shall submit all engineering design and electrical specifications associated with the Interconnection Customer’s Interconnection Facilities to the Connecting Transmission Owner for its review and acceptance in accordance with the ESBs and Project Specific Specifications. The metering of any redundant or standby station service provisions at the Xxxxxxxxx Solar Collector Substation shall be added in accordance with the Connecting Transmission Owner’s retail tariff, P.S.C. No. 220, and the Connecting Transmission Owner’s ESB 750. As per the Project Specific Specifications, the Interconnection Customer will install the RTU provided by Connecting Transmission Owner in accordance with Connecting Transmission Owner’s ESBs, indoors and within 15 feet of the meter(s), and remote from: • heavy traffic areas, work areas, and loading areas; • heat producing or high electrostatic or electromagnetic field producing equipment; and • station batteries. (Note: If no indoor facility is available, then installation of the RTU and revenue metering equipment in a dedicated, weatherproof, heated cubicle (accessible only to Connecting Transmission Owner) is acceptable.) For the revenue metering, the Interconnection Customer shall install a meter panel in accordance with the Project Specific Specifications, ESB 752 and ESB 750. The Interconnection Customer shall mount the revenue metering CT/PT units, make grounding connections, and complete all primary wiring. The Interconnection Customer shall install the meter socket enclosure near the Connecting Transmission Owner’s RTU in accordance with the Project Specific Specifications. Additional right-of-way (“ROW”) will be required for the construction, operation, and maintenance of the Line 301 Tap and must accommodate the 125’ x 125’ work pads required for the installation of the new structures. The Interconnection Customer is responsible for obtaining the property/easements needed for the Line 301 Tap line, access roads to/from the Line 301 Tap, and work pads, in accordance with the standards set forth in the Connecting Transmission Owner’s Standards and Requirements Relating to Third Party Acquisition and Transfer of Real Property Interests to Niagara Mohawk Power Corporation for Electric Facilities and Survey Specifications (January 2019). The Interconnection Customer is responsible for all permitting. Upon termination of this Agreement, Interconnection Customer shall be responsible for all costs associated with the decommissioning and removal of the Connecting Transmission Owner’s Interconnection Facilities.

  • HIV/AIDS Model Workplace Guidelines Grantee will:

  • Adjunct Duties 9.2.1 The District and the Association recognize that teachers participate in adjunct duties. Adjunct duties are those duties beyond the work day, which require supervising and providing leadership in pupil organizations and activities or parent-teacher partnership such as, but not limited to: field trips, back-to-school night, graduation, promotion, outdoor education, open house, parent club, teacher conferences, progress report card night, supervision of dances, sponsorship of clubs, homecoming activities, and supervision of athletic events. These duties must be student supervision oriented. Attendance at Back to School Night, Open House, Progress Report Night, Teacher Conferences is required unless specific prior approval is given to miss the meeting/event.

  • Connecting Transmission Owner’s Scope of Work and Responsibilities The Connecting Transmission Owner will design, construct, own, operate and maintain all Connecting Transmission Owner’s Interconnection Facilities, except as otherwise stated above and in the Project Specific Specifications. The Connecting Transmission Owner will complete all engineering reviews, field verifications and witness testing, etc. in accordance with the ESBs and the Project Specific Specifications. Connecting Transmission Owner shall provide the revenue metering CT/PT units and meter socket enclosure. The Connecting Transmission Owner shall:  provide, run, and wire both ends of the color-coded cable for the revenue metering instrument transformer secondary wiring;  perform all terminations; and  supply and install the meter. The revenue meter may require a communications link to the RTU. The Connecting Transmission Owner will specify and run those communications cables. The Connecting Transmission Owner shall complete all wiring, testing and commissioning of the RTU.

  • The Services The HSP agrees to provide the Services on the terms and conditions of this PFA including all of its Appendices and schedules.

  • Tasks In order to accomplish the work described herein, the Contractor shall perform each of the following tasks:

  • Use of local labour professional services and materials 10. (1) The Company shall, for the purposes of this Agreement —

Time is Money Join Law Insider Premium to draft better contracts faster.