eFiling Direct Connector Sample Clauses

eFiling Direct Connector. The eFiling Direct Connector must be a XML based, secured, access controlled web service that will allow EFSPs to submit filings to the EFM and to manage filer user accounts. The eFiling Direct Connector must employ security so that the transmissions are encrypted and initiated from known sources. Upon a successful submission, the eFiling Direct Connector must provide a success code and a confirmation number back to the EFSP. The eFiling Direct Connector must then insert the filing and metadata into the EFM for further processing by the clerk’s office. If the filing is unsuccessful, the eFiling Direct Connector must return an error code that can be deciphered by the EFSP for further action by the filer. The eFiling Direct Connector must provide standard interface messaging in order for the EFSPs to determine the current status of submitted filings. The system must provide back to the EFSPs the following information: • unique trace number of the filing • the outcome of the filing (accepted, rejected or error) • the date/time the outcome was determined • access to the file-stamped copy of the document The web services must be implemented in compliance with the Electronic Case File 4.0 standard and any future revisions. Xxxxx shall support the following services: • FilingAssembly – submits the assembled filing document(s) and metadata and makes them available for court review • GetPolicy – retrieves the policy information of a specific court in an XML format • GetFeesCalculation – retrieves the fees applicable for the given filing • GetFilingList – retrieves the list of filings that match the given parameters (filer, case, or date range) • GetFilingStatus – retrieves the current status of a filing Xxxxx shall provide the following identification management web services: • Authenticate a user by user name and passwordRegister a new user account • Deactivate a user account • Update the email address on the account • Retrieve the security question for a user by user name (to support password reset) • Reset the password of a user by user name, given the matching response to the security question Xxxxx must provide to EFSPs the service interface documentation to the eFiling Direct Connector web services.
AutoNDA by SimpleDocs

Related to eFiling Direct Connector

  • Signaling Parameters All SS7 signaling parameters will be provided in conjunction with traffic exchange trunk groups, where and as available. These parameters include Automatic Number Identification ("ANI"), Calling Party Number ("CPN"), Privacy Indicator, calling party category information, originating line information, charge number, etc. Also included are all parameters relating to network signaling information, such as Carrier Information Parameter ("CIP"), wherever such information is needed for call routing or billing. GTE will provide SS7 via GR-394-SS7 and/or GR-317-SS7 format(s).

  • Signaling protocol The Parties will interconnect their networks using SS7 signaling where Technically Feasible and available as defined in GR 905 Telcordia Standards including ISDN User Part (ISUP) for trunk signaling and TCAP for CCS-based features in the Interconnection of their networks. All Network Operations Forum (NOF) adopted standards shall be adhered to. Where available, CenturyLink signaling services to link its Signaling Transfer Points (STPs) for CLEC switches which connect to CenturyLink’s STPs via “A” links or for CLEC’s STPs to connect to CenturyLink’s STPs via “D” links which are dedicated to the transport of signaling for local Interconnection, may be ordered from the CenturyLink Tariff.

  • Contact Tracing While the employees are on the job site, Producers may require that employees participate in systems that enable contact tracing, such as use of a “punch card” system to record the employee’s location throughout the day or by means of electronic devices (e.g., phone “apps” or wearable electronic devices that track the movement or location of a person or which detect when a person wearing the device comes into close contact with another person wearing the device). Producers may require employees to sign documentation consenting to the use of such electronic devices in contact tracing. In the event that a Producer uses electronic devices for contact tracing, it may access information collected from those devices only for purposes of tracing individuals that the employee has been in contact with during working hours when there has been a COVID- 19-related event, or for purposes of managing and enforcing social distancing protocols.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where InterGlobe has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to InterGlobe. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for InterGlobe (e.g. hairpinning):

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Configuration Management The Contractor shall maintain a configuration management program, which shall provide for the administrative and functional systems necessary for configuration identification, control, status accounting and reporting, to ensure configuration identity with the UCEU and associated cables produced by the Contractor. The Contractor shall maintain a Contractor approved Configuration Management Plan that complies with ANSI/EIA-649 2011. Notwithstanding ANSI/EIA-649 2011, the Contractor’s configuration management program shall comply with the VLS Configuration Management Plans, TL130-AD-PLN-010-VLS, and shall comply with the following:

  • Server Use This agreement does not permit you to install or Use the Software on a computer file server. For information on Use of Software on a computer file server please refer to xxxx://xxx.xxxxx.xxx/go/acrobat_distribute for information about Adobe Reader; or xxxx://xxx.xxxxx.xxx/go/licensing for information about the Adobe Runtimes.

  • Local Switching Interfaces 4.2.13.1 Newcomm shall order ports and associated interfaces compatible with the services it wishes to provide as listed in Exhibit A. BellSouth shall provide the following local switching interfaces:

  • Interface A defined set of transmission facilities that separate Load Zones and that separate the NYCA from adjacent Control Areas. Investor-Owned Transmission Owners. A Transmission Owner that is owned by private investors. At the present time these include: Central Xxxxxx Gas & Electric Corporation, Consolidated Edison Company of New York, Inc., New York State Electric & Gas Corporation, Niagara Mohawk Power Corporation, Orange and Rockland Utilities, Inc., and Rochester Gas and Electric Corporation.

Time is Money Join Law Insider Premium to draft better contracts faster.