Geysers Sample Clauses

Geysers. 12.1 Replace 100L geysers SUPPLIED BY ESKOM(horisontal/ vertical) EA 30 12.2 Replace 150L geyser SUPPLIED BY ESKOM (horisontal/vertical) EA 30 12.3 Install a 100L GEYSER IN OUTSIDE BUILDINGS GEYSER TO BE SUPPLIED BY ESKOM. OWN PRESSURE VALVE, vacuum breakers and overflows TO BE SUPPLIED. EA 15 12.3 Install a 150L GEYSER – ESKOM TO SUPPLY GEYSER, own VACUUM BREAKERS and overflows. GEYSER TRAY AND OVERFLOW PIPES TO BE SUPPLIED BY CONTRACTOR EA 10 13 INSTALL GEYSER OVERFLO PIPES WITH COPPER PIPES CLASS (O) AND CAPILLARY FITTINGS TO FIT VALVE SPECIFICATIONS. THE PIPE MUST PROTRUDE ON THE OUTSIDE WALL BY 150mm 13.1 INSTALL GEYSER VALVE OVERFLO WITH 15mm COPPER PIPE CLASS O WITH CAPPILARY FITTINGS P/Meter 8 13.2 INSTALL GEYSER SAFETY VALVE OVERFLO PIPE WITH 22mm COPPER PIPE & CAPPILARY FITTINGS P/Meter 12 13.4 INSTALL GEYSER TRAY, INCLUDING OVERFLO PIPE S.A.B.S. 50mm P.V.C FITTINGS, WITH A SLIGHT FALL TO OULET. TO BE GLUED WITH P.V.C GLUE, TRAY OUTLET FITTING TO BE SEALED WATERTITE WITH SILICONE SEALANT (SEE SPECS ON REPLACING GEYSER ON P 18). EA 5 14 SINK TOPS 14.1 Replace double sink top EA 5 14.2 Replace single sink top EA 10 14.3 Replace rubber cone on water inlet from cistern EA 13 14.4 Replace beta valve complete (PVC dpi) EA 4 14.5 Replace beta valve washer EA 12 14.6 Replace flush pipe EA 6 14.7 RECEAL FLUSHPIPE EA 1 14.8 REPLACE leaking pan connector 110mm EA 3 14.9 REPAIR LEAKING PANCONNECT 110mm EA 3 14.10 REPLACE VANITY BASIN WITH SIMILAR TYPE- SAME TAPS – NEW WASTE FITTINGS EA 2 14.11 SUPPLY & INSTALL P.V.C BOSS ADAPTER 110mm x 50mm EA 4 14.12 REPLACE T-PIECE 50mm P.V.C PLAIN EA 6 14.13 REPLACE ELBOW 900 50mm P.V.C PLAIN EA 5 14.14 REPLACE ROOF FLASHINGS ON TILE ROOFS (SIMILAR TYPE) P/Meter 6 14.15 REPLACE TOILET PAN – WHITE P- TRAP EA 8 14.16 REPLACE TOILET PAN – WHITE P – TRAP CLOSE COUPLE EA 4 14.17 REPLACE 110mm P.V.C JUNCTION ABOVE GROUND EA 6 14.18 REPLACE 110mm P.V.C I .E BENDS ABOVE GROUND EA 8 14.19 INSTALL 110 mm P.V.C XXXXXXXX SOCKET EA 8 14.20 INSTALL GARDEN TAP ½" COBRA HEAVY DUTY 108/15 EA 6 14.21 REPALCE GARDEN TAP ½" COBRA HEAVY DUTY 108/15 EA 6 14.22 INSTALL GARDEN TAP ½" mount ¾'' hose fitting plastic type cobra. Heavy Duty. 108/15 Supply and Fit. EA 15 14.23 INSTALL WASTE FITTING COBRA 1 ½"(400MM) EA 10 14.24 REPLACE WASTE FITTING COBRA 1 ½"(400MM) EA 10 14.25 INSTALL BASIN WASTE FITTING 1 ½" (40MM) EA 6 14.26 REPLACE BASIN WASTE FITTING 1 ¼" (32MM) EA 6 14.27 REPLACE BUNG RUBBER EA 10 14.28 INSTALL 110mm PVC END CAP TO BLANK OFF ...
AutoNDA by SimpleDocs
Geysers. 10.1 Supply and Install 150L geyser - complete installation with fittings EA 15
Geysers. Domestic-type geysers will be supplied, installed and connected to water services by others. The Contractor shall undertake all electrical connections. For wall mounted geysers, flush supply conduit shall terminate in a flush round box conveniently close to the electrical entry to the water heater. A surface type metal clad or polycarbonate encased 30 A DP switch dis-connector shall be superimposed over the conduit box and the final connection shall be made using surface galvanized conduit, painted after installation. Where geysers are installed in concealed positions such as roof voids, the final connection from the local switch dis-connector may comprise PVC covered flexible steel conduit. Unless otherwise indicated in the single line diagrams, wiring for geyser circuits not exceeding 4 kW single-phase shall be carried out with conductors and earth wire at least 2,5mm² each. Connections to calorifiers and large type geysers shall be as specified.
Geysers. 35.1 The Lessor shall be responsible for the maintenance and/or repair and/or replacement of the geysers. Notwithstanding the Lessor’s obligation to undertake any maintenance and/or repair and/or replacement of the geysers, the Lessee shall at all times be liable for the cost of any installation, repair, maintenance and/or replacement of the geysers, if the geyser supplies the Lessee only, alternatively if more than one Lessee uses same, the Lessee shall be liable for its Tenant’s Proportionate Share.
Geysers 

Related to Geysers

  • Water Resources Four (4) Union Stewards unless the unit falls below sixty (60) employees and then not more than two (2) Union Stewards.

  • Business Partners Red Hat has entered into agreements with other organizations (“Business Partners”) to promote, market and support certain Software and Services. When Client purchases Software and Services through a Business Partner, Red Hat confirms that it is responsible for providing the Software and Services to Client under the terms of this Agreement. Red Hat is not responsible for (a) the actions of Business Partners, (b) any additional obligations Business Partners have to Client, or (c) any products or services that Business Partners supply to Client under any separate agreements between a Business Partner and Client.

  • WTO GPA DR-CAFTA. —NAFTA. —U.S.-Australia FTA. —U.S.-Bahrain FTA. —U.S.-Chile FTA. —U.S.-Morocco FTA. —U.S.-Oman FTA. —U.S.-Peru TPA. —U.S.-Singapore FTA. —

  • Natural Resources Protecting America’s great outdoors and natural resources.

  • Asset Management Supplier will: i) maintain an asset inventory of all media and equipment where Accenture Data is stored. Access to such media and equipment will be restricted to authorized Personnel; ii) classify Accenture Data so that it is properly identified and access to it is appropriately restricted; iii) maintain an acceptable use policy with restrictions on printing Accenture Data and procedures for appropriately disposing of printed materials that contain Accenture Data when such data is no longer needed under the Agreement; iv) maintain an appropriate approval process whereby Supplier’s approval is required prior to its Personnel storing Accenture Data on portable devices, remotely accessing Accenture Data, or processing such data outside of Supplier facilities. If remote access is approved, Personnel will use multi-factor authentication, which may include the use of smart cards with certificates, One Time Password (OTP) tokens, and biometrics.

  • Energy 1. Cooperation shall take place within the principles of the market economy and the European Energy Charter, against a background of the progressive integration of the energy markets in Europe.