Common use of Instrumentation Clause in Contracts

Instrumentation. Test stations shall be equipped with instruments to measure the U value to an accuracy of ± 5%. Heat transfer through air leakage should not exceed 5% of the total heat transfer through the calorimeter box or through the insulated body of the unit of transport equipment. The refrigerating capacity shall be determined with an accuracy of ± 5%. The instrumentation of the calorimeter box or unit of transport equipment shall conform to paragraphs 4 1.3 and 1.4 above. The following are to be measured:

Appears in 4 contracts

Samples: Agreement on the International Carriage of Perishable Foodstuffs and on the Special Equipment to Be Used for Such Carriage (Atp), Agreement on the International Carriage of Perishable Foodstuffs, Agreement on the International Carriage of Perishable Foodstuffs and on the Special Equipment to Be Used for Such Carriage (Atp)

AutoNDA by SimpleDocs

Instrumentation. Test stations shall be equipped with instruments to measure the U value to an accuracy of ± 5%. Heat transfer through air leakage should not exceed 5% of the total heat transfer through the calorimeter box or through the insulated body of the unit of transport equipment. The refrigerating capacity shall be determined with an accuracy of ± 5±5%. The instrumentation of the calorimeter box or unit of transport equipment shall conform to paragraphs 3 and 4 1.3 and 1.4 above. The following are to be measured:

Appears in 3 contracts

Samples: Agreement on the International Carriage of Perishable Foodstuffs and on the Special Equipment to Be Used for Such Carriage (Atp), Agreement on the International Carriage of Perishable Foodstuffs and on the Special Equipment to Be Used for Such Carriage (Atp), Agreement on the International Carriage of Perishable Foodstuffs and on the Special Equipment to Be Used for Such Carriage (Atp)

AutoNDA by SimpleDocs

Instrumentation. Test stations shall be equipped with instruments to measure the U value to an accuracy of ± 5±5%. Heat Beat transfer through air leakage should not exceed 5% of the total heat transfer through the calorimeter box or through the insulated body of the unit of transport equipment. The refrigerant flow measurement shall be accurate to ±5%. The refrigerating capacity shall be determined with an accuracy of ± 5±10%. The instrumentation of the calorimeter box or unit of transport equipment shall conform to paragraphs 3 and 4 1.3 and 1.4 above. The following are to be measured:

Appears in 1 contract

Samples: Agreement on the International Carriage of Perishable Foodstuffs

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!