Interim Operations Facilities Sample Clauses

Interim Operations Facilities. Relocation of five of the current on-airport rental car concessionaires’ (Advantage, Avis, Budget, Hertz and National) on-airport customer operations to the OST garage and to interim quick-turnaround area (“QTA”) facilities; common busing implemented for these concessionaires; demolition of their on-airport facilities for construction of permanent facility (Phase 2B).
AutoNDA by SimpleDocs

Related to Interim Operations Facilities

  • Interim Operations (a) The Company covenants and agrees as to itself and its Subsidiaries that, from and after the execution of this Agreement and prior to the Effective Time (unless Parent shall otherwise approve in writing, which approval shall not be unreasonably withheld, conditioned or delayed, and except as (1) required by applicable Law, (2) expressly required by this Agreement or (3) otherwise expressly disclosed in Section 6.1(a) of the Company Disclosure Letter), the Company shall use its reasonable best efforts to conduct its business and the business of its Subsidiaries in the ordinary course of business consistent with past practice and each of the Company and its Subsidiaries shall, subject to compliance with the specific matters set forth below, use reasonable best efforts to preserve its business organization intact and maintain the existing relations and goodwill with Governmental Entities, customers, suppliers, distributors, licensors, creditors, lessors, employees and business associates and others having material business dealings with it and keep available the services of the Company and its Subsidiaries’ present employees and agents. Without limiting the generality of, and in furtherance of, the foregoing, the Company covenants and agrees as to itself and its Subsidiaries that, from and after the date of this Agreement and prior to the Effective Time, except (A) as required by applicable Law, (B) as Parent may approve in writing (such approval not to be unreasonably withheld, conditioned or delayed), (C) as expressly disclosed in Section 6.1(a) of the Company Disclosure Letter or (D) as expressly provided for in this Agreement, the Company shall not and will not permit any of its Subsidiaries to:

  • Verizon OSS Facilities Any gateways, interfaces, databases, facilities, equipment, software, or systems, used by Verizon to provide Verizon OSS Services to CBB.

  • PUBLIC FACILITIES Supplier’s employees may be required to perform work at government- owned facilities, including schools. Supplier’s employees and agents must conduct themselves in a professional manner while on the premises, and in accordance with Participating Entity policies and procedures, and all applicable laws.

  • Network Facilities At the time of termination, the Transmission Provider and the Interconnected Entities shall keep in place any portion of the Interconnection Facilities that the Transmission Provider deems necessary for the safety, integrity and/or reliability of the Transmission System. Otherwise, Transmission Provider may, in its discretion, within 30 days following termination of Interconnection Service, require the removal of all or any part of the Interconnection Facilities.

  • Interconnection Facilities 4.1.1 The Interconnection Customer shall pay for the cost of the Interconnection Facilities itemized in Attachment 2 of this Agreement. The NYISO, in consultation with the Connecting Transmission Owner, shall provide a best estimate cost, including overheads, for the purchase and construction of its Interconnection Facilities and provide a detailed itemization of such costs. Costs associated with Interconnection Facilities may be shared with other entities that may benefit from such facilities by agreement of the Interconnection Customer, such other entities, the NYISO, and the Connecting Transmission Owner.

  • Operations Fire An “Operations Fire” is a fire caused by Purchaser’s Operations other than a Neg- ligent Fire. Forest Service, except as provided in B7.3, shall use cooperative deposits under B4.218 to perform fire sup- pression activities on Operations Fires. Xxxxxxxxx agrees to reimburse Forest Service for such cost for each Opera- tions Fire, subject to a maximum of the dollar amount stated in A14. The cost of Purchaser’s actions, supplies, and equipment on any such fire provided pursuant to B7.3, or otherwise at the request of Forest Service, shall be credited toward such maximum. If Purchaser’s actual cost exceeds Purchaser’s obligation stated in A14, Forest Service shall reimburse Purchaser for the excess.

  • BUYER'S FACILITIES 1. Buyer will maintain at its own expense facilities from the delivery point to the point of use and the burners and equipment for using gas, and Buyer will at all times keep gas-using equipment on said premises in a condition conforming with such reasonable rules and regulations as may be prescribed therefore by regulatory authority having jurisdiction thereover and with the requirements of any valid law thereto appertaining. In the event that rules are not prescribed by a regulatory authority, Buyer will abide by codes as used in the gas industry.

  • New Facilities For all new Generating Facilities to be interconnected pursuant to the Tariff, other than wind- powered and other non-synchronous generation facilities, the Generation Interconnection Customer shall design its Customer Facility to maintain a composite power delivery at continuous rated power output at a power factor of at least 0.95 leading to 0.90 lagging. For all new wind- powered and other non-synchronous generation facilities the Generation Interconnection Customer shall design its Customer Facility with the ability to maintain a composite power delivery at a power factor of at least 0.95 leading to 0.95 lagging across the full range of continuous rated power output. For all wind-powered and other non-synchronous generation facilities entering the New Service Queue on or after November 1, 2016, the power factor requirement shall be measured at the high-side of the facility substation transformers. This power factor range standard shall be dynamic and can be met using, for example, power electronics designed to supply this level of reactive capability (taking into account any limitations due to voltage level, real power output, etc.) or fixed and switched capacitors, or a combination of the two. For all wind-powered and other non-synchronous generation facilities entering the New Service Queue on or after May 1, 2015, and before November 1, 2016, the power factor requirement shall be measured at the generator’s terminals. For new generation resources of more than 20 MW, other than wind- powered and other non-synchronous Generating Facilities, the power factor requirement shall be measured at the generator’s terminals. For new generation resources of 20 MW or less, and all wind-powered and other non-synchronous generation facilities entering the New Service Queue prior to May 1, 2015, the power factor requirement shall be measured at the Point of Interconnection. Any different reactive power design criteria that Transmission Provider determines to be appropriate for a wind-powered or other non-synchronous generation facility shall be stated in the Interconnection Service Agreement. A Transmission Interconnection Customer interconnecting Merchant D.C. Transmission Facilities and/ or Controllable A.C. Merchant Transmission Facilities shall design its Customer Facility to maintain a power factor at the Point of Interconnection of at least 0.95 leading and 0.95 lagging, when the Customer Facility is operating at any level within its approved operating range.

  • Existing Facilities Each of the Existing Facilities shall be repaid in full and terminated and all collateral security therefor shall be released, and the Administrative Agent shall have received pay-off letters in form and substance satisfactory to it evidencing such repayment, termination and release.

  • PROJECT 3.01. The Recipient declares its commitment to the objectives of the Project. To this end, the Recipient shall carry out the Project in accordance with the provisions of Article IV of the General Conditions.

Time is Money Join Law Insider Premium to draft better contracts faster.