LEAP Provisioning. Contractor shall use the same method to provision LEAP as is currently used daily to create Bulk Data Downloads (BDDs). In order to build a BDD, a script currently is run against a copy of the NPAC/SMS database stored on a disk that is created daily located on a NeuStar server that is not associated with the NPAC/SMS. Contractor maintains an FTP site with “folders” for each User. If a User requests a BDD file, then the BDD file is placed on the requester’s folder on the FTP site. The FTP site is located on a NeuStar server that is not associated with the NPAC/SMS. The script to derive data from the copy of the NPAC/SMS database to provision LEAP is different from a BDD script in terms of the data retrieved, but the process involved is the same. The LEAP script obtains only data that are defined as LEA Data Elements in accordance with Section 15.8. When the LEAP script is run, the resulting data are placed in the FTP folder assigned to LEAP. The data in the LEAP folder on the FTP site then is loaded into LEAP where it becomes available for queries by Qualified LEAs under the LEAP Service. SOW: þ No o Yes
AutoNDA by SimpleDocs

Related to LEAP Provisioning

  • Provisioning 2.4.1 BellSouth shall provision services during its regular working hours. To the extent OneTone requests provisioning of service to be performed outside BellSouth’s regular working hours, or the work so requested requires BellSouth’s technicians or project managers to work outside of regular working hours, overtime charges set forth in BellSouth’s intrastate Access Services Tariff, Section E13.2, shall apply. Notwithstanding the foregoing, if such work is performed outside of regular working hours by a BellSouth technician or project manager during his or her scheduled shift and BellSouth does not incur any overtime charges in performing the work on behalf of OneTone, BellSouth will not assess OneTone additional charges beyond the rates and charges specified in this Agreement. 2.4.2 In the event BellSouth must dispatch to the End User’s location more than once due to incorrect or incomplete information provided by OneTone (e.g., incomplete address, incorrect contact name/number, etc.), BellSouth will xxxx OneTone for each additional dispatch required to provision the circuit due to the incorrect/incomplete information provided. BellSouth will assess the applicable Maintenance of Service rates from BellSouth’s XXX Xx. 0 Xxxxxx, Xxxxxxx 13.3.1.

  • Maintenance Scheduling The NTO shall schedule maintenance of its facilities designated as NTO Transmission Facilities Under ISO Operational Control and schedule any outages (other than forced transmission outages) of said transmission system facilities in accordance with outage schedules approved by the ISO. The NTO shall comply with maintenance schedules coordinated by the ISO, pursuant to this Agreement, for NTO Transmission Facilities Under ISO Operational Control. The NTO shall be responsible for providing notification of maintenance schedules to the ISO for NTO Transmission Facilities Requiring ISO Notification. The NTO shall provide notification of maintenance schedules to affected Transmission Owners for NTO Transmission Facilities Requiring ISO Notification and Local Area Transmission Facilities pursuant to Section 3.5.3 of the ISO Services Tariff.

  • Start-Up and Synchronization Consistent with the mutually acceptable procedures of the Developer and Connecting Transmission Owner, the Developer is responsible for the proper synchronization of the Large Generating Facility to the New York State Transmission System in accordance with NYISO and Connecting Transmission Owner procedures and requirements.

  • Provisioning Line Splitting and Splitter Space 3.8.1 The Data LEC, Voice CLEC or BellSouth may provide the splitter. When Southern Telecom or its authorized agent owns the splitter, Line Splitting requires the following: a non-designed analog Loop from the serving wire center to the NID at the End User’s location; a collocation cross connection connecting the Loop to the collocation space; a second collocation cross connection from the collocation space connected to a voice port; the high frequency spectrum line activation, and a splitter. The Loop and port cannot be a Loop and port combination (i.e. UNE-P), but must be individual stand-alone Network Elements. When BellSouth owns the splitter, Line Splitting requires the following: a non designed analog Loop from the serving wire center to the NID at the End User’s location with CFA and splitter port assignments, and a collocation cross connection from the collocation space connected to a voice port. 3.8.2 An unloaded 2-wire copper Loop must serve the End User. The meet point for the Voice CLEC and the Data LEC is the point of termination on the MDF for the Data LEC's cable and pairs. 3.8.3 The foregoing procedures are applicable to migration to Line Splitting Service from a UNE-P arrangement, BellSouth Retail Voice Service, BellSouth High Frequency Spectrum (CO Based) Line Sharing. 3.8.4 For other migration scenarios to line splitting, BellSouth will work cooperatively with CLECs to develop methods and procedures to develop a process whereby a Voice CLEC and a Data LEC may provide services over the same Loop.

  • Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Xxxx has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Xxxx. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Xxxx (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Xxxx, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Xxxx will then have the option of paying the one-time SC rates to place the Loop.

  • Maintenance Programme (i) The Contractor shall prepare a monthly maintenance programme (the “Maintenance Programme”) in consultation with the Authority’s Engineer and submit the same to the Authority’s Engineer not later than 10 (ten) days prior to the commencement of the month in which the Maintenance is to be carried out. For this purpose a joint monthly inspection by the Contractor and the Authority’s Engineer shall be undertaken. The Maintenance Programme shall contain the following: (a) The condition of the road in the format prescribed by the Authority’s Engineer; (b) the proposed maintenance Works; and (c) deployment of resources for maintenance Works.

  • Ordering and Provisioning 53.3.1 CenturyLink will provide necessary ordering and provisioning business process support as well as those technical and systems interfaces as may be required to enable CLEC to provide resale services, including the functions, features, and capabilities of such services, and Unbundled Network Elements. If CenturyLink deploys any enhanced electronic capability CenturyLink will notify CLEC of availability and CLEC shall use the processes for performing transaction(s) to the extent practicable and the use of any other interface or process will be discontinued. 53.3.2 The Parties agree that orders for services under this Agreement will not be submitted or accepted until thirty (30) Days after the completion of all account establishment activities, including but not limited to, the documents and information subscribed in Section 45.1, unless the Parties mutually agree upon a different date based on the specific circumstances of the Parties’ relationship. 53.3.3 Except as specifically provided otherwise in this Agreement, pre- ordering, ordering and provisioning of resold services shall be governed in accordance with CenturyLink’s Standard Practices. 53.3.4 CenturyLink will provide provisioning intervals and procedures for design and complex services on a nondiscriminatory basis. Complex Service Order charges pursuant to Tariff terms may apply. 53.3.5 Where Technically Feasible, the NEAC will coordinate support for all designed and/or complex services provided to CLEC. 53.3.6 To the extent required by Applicable Law, and upon request from CLEC, employing CenturyLink’s LSR, CenturyLink will provide blocking of 700, 900, and 976 services, or other services of similar type as may now exist or be developed in the future, and shall provide Billed Number Screening (BNS), including required LIDB updates, or equivalent service for blocking completion of bill-to-third party and collect calls, on a line, PBX, or individual service basis. Blocking shall be provided to the extent (a) it is an available option for the Telecommunications Service resold by CLEC, or (b) it is Technically Feasible when requested by CLEC as a function of Unbundled Network Elements. 53.3.7 When ordering a resale service via an LSR Service Order, CLEC may order separate interLATA and IintraLATA service providers (i.e., two PICs) on a line or trunk basis, and CLEC agrees to pay the applicable Service Order and PIC charges associated with such order. CenturyLink will accept PIC change orders for IntraLATA toll and long distance services through the service provisioning process. 53.3.8 The standard Service Order charges as listed in the Table 1 of this Agreement shall apply to all orders.

  • Scope of Interconnection Service 1.3.1 The NYISO will provide Energy Resource Interconnection Service and Capacity Resource Interconnection Service to Interconnection Customer at the Point of Interconnection. 1.3.2 This Agreement does not constitute an agreement to purchase or deliver the Interconnection Customer’s power. The purchase or delivery of power and other services that the Interconnection Customer may require will be covered under separate agreements, if any, or applicable provisions of NYISO’s or Connecting Transmission Owner’s tariffs. The Interconnection Customer will be responsible for separately making all necessary arrangements (including scheduling) for delivery of electricity in accordance with the applicable provisions of the ISO OATT and Connecting Transmission Owner’s tariff. The execution of this Agreement does not constitute a request for, nor agreement to, provide Energy, any Ancillary Services or Installed Capacity under the NYISO Services Tariff or any Connecting Transmission Owner’s tariff. If Interconnection Customer wishes to supply or purchase Energy, Installed Capacity or Ancillary Services, then Interconnection Customer will make application to do so in accordance with the NYISO Services Tariff or Connecting Transmission Owner’s tariff.

  • Maintenance Manual No later than 60 (sixty) days prior to the Project Completion Date, the Contractor shall, in consultation with the Authority’s Engineer, evolve a maintenance manual (the “Maintenance Manual”) for the regular and preventive maintenance of the Project Highway in conformity with the Specifications and Standards, safety requirements and Good Industry Practice, and shall provide 5 (five) copies thereof to the Authority’s Engineer. The Authority’s Engineer shall review the Maintenance Manual within 15 (fifteen) days of its receipt and communicate its comments to the Contractor for necessary modifications, if any.

  • Installation, Maintenance, Testing and Repair Unless otherwise agreed in writing by the Parties, to the extent required by Applicable Law, Interconnection provided by a Party shall be equal in quality to that provided by such Party to itself, any subsidiary, affiliates or third party. If either Party is unable to fulfill its obligations under this Section 14.2, it shall notify the other Party of its inability to do so and will negotiate alternative intervals in good faith. The Parties agree that to the extent required by Applicable Law, the standards to be used by a Party for isolating and clearing any disconnections and/or other outages or troubles shall be at parity with standards used by such Party with respect to itself, any subsidiary, affiliate or third party.