Modes for Fault Tolerant Systems Sample Clauses

Modes for Fault Tolerant Systems. The use of modes together with a refinement approach, as introduced in the previous sections, offers suitable abstractions to modelling and reasoning about fault tolerant systems, as discussed in the following. Due to the use of a state-based approach, state representation, manipulation and reasoning becomes natural. The support provided by modes allows to partition the state space into normal and erroneous: mode assumptions allow this separation to be declared and erroneous states made explicit. Refinement allows further definition of erroneous states into more specific ones. Assumptions on normal and erroneous states can be suitably associated to modes in charge of performing normal system operation and fault tolerance measures, respectively. In general, a recovery mode should be associated with a particular normal mode, which it recovers, and mode switching is in some sense reminiscent to calling an exception handler in pro- gramming languages. Error detection is immediate, embedded in the erroneous state assumption of a recovery mode. As soon as a state transition leads to the characterization of an erroneous state, the recovery mode is enabled. A more concrete view is to consider the existence of a detec- tion mechanism, which is active during normal operation. In such case the detection mechanism affects the state used in the assumptions of normal and recovery modes. By refinement one could start with the first and reach the second, more detailed model. Any of the possibilities allow switching to recovery mode from any normal mode state. For reasoning purposes, one can intro- duce the possibility of fault occurrences in parallel with the model. In an event based formalism this takes the form of an enabled event that affects the state to satisfy the erroneous state assump- tion. The recovery mode has access to the state of the respective normal mode. Analogously to assumptions, guarantees associated to normal or recovery modes assist to define properties of the system in absence or presence of errors, respectively. Depending on the severity of the detected error, the mode system may assert that the recovery procedure: (i) successfully recovers the state and thus switches back to normal mode to proceed execution (Figure 1(B) or (C)); (ii) provides degraded service in cases where full functionality is not recoverable (Figure 1(D)); (iii) fails to recover, in which case measures to stop safely may be taken (Figure 1(A) and part of (D)). Normal Fail−safe ...
AutoNDA by SimpleDocs
Modes for Fault Tolerant Systems. The use of modes together with a refinement approach, as introduced in the previous sections, offers suitable abstractions to modelling and reasoning about fault tolerant systems, as discussed in the following. Due to the use of a state-based approach, state representa- tion, manipulation and reasoning becomes natural. The support provided by modes allows to partition the state space into normal and erroneous: mode assumptions allow this separation to be declared and erroneous states made explicit. Refinement allows further definition of erroneous states into more specific A2(u)/G2(u, u ) iff I(v) ∧ J(v, u) ∧ A(v) ⇒ A1(u) ∨ A2(u) I(v) ∧ J(v, u) ∧ G1(u, uj) ∨ G2(u, uj) ⇒ G(v, vj)

Related to Modes for Fault Tolerant Systems

  • Access Rights for implementation Access Rights to Results and Background Needed for the performance of the own work of a Party under the Project shall be granted on a royalty-free basis, unless otherwise agreed for Background in Attachment 1.

  • Benchmarks for Measuring Accessibility For the purposes of this Agreement, the accessibility of online content and functionality will be measured according to the W3C’s Web Content Accessibility Guidelines (WCAG) 2.0 Level AA and the Web Accessibility Initiative Accessible Rich Internet Applications Suite (WAI-ARIA) 1.0 for web content, which are incorporated by reference. Adherence to these accessible technology standards is one way to ensure compliance with the College’s underlying legal obligations to ensure that people with disabilities are able to acquire the same information, engage in the same interactions, and enjoy the same benefits and services within the same timeframe as their nondisabled peers, with substantially equivalent ease of use; that they are not excluded from participation in, denied the benefits of, or otherwise subjected to discrimination in any College programs, services, and activities delivered online, as required by Section 504 and the ADA and their implementing regulations; and that they receive effective communication of the College’s programs, services, and activities delivered online.

  • Technical Requirements for SCPs/Databases 10.5.3.1 BellSouth shall provide physical access to SCPs through the SS7 network and protocols with TCAP as the application layer protocol.

  • Joint Network Implementation and Grooming Process Upon request of either Party, the Parties shall jointly develop an implementation and grooming process (the “Joint Grooming Process” or “Joint Process”) which may define and detail, inter alia:

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Linking to the Website and Social Media Features You may link to our homepage, provided you do so in a way that is fair and legal and does not damage our reputation or take advantage of it, but you must not establish a link in such a way as to suggest any form of association, approval, or endorsement on our part. This Website may provide certain social media features that enable you to: • Link from your own or certain third-party websites to certain content on this Website. • Send emails or other communications with certain content, or links to certain content, on this Website. • Cause limited portions of content on this Website to be displayed or appear to be displayed on your own or certain third-party websites. You may use these features solely as they are provided by us, and solely with respect to the content they are displayed with, and otherwise in accordance with any additional terms and conditions we provide with respect to such features. Subject to the foregoing, you must not: • Establish a link from any website that is not owned by you. • Cause the Website or portions of it to be displayed on, or appear to be displayed by, any other site, for example, framing, deep linking, or in-line linking. • Link to any part of the Website other than the homepage. • Otherwise take any action with respect to the materials on this Website that is inconsistent with any other provision of these Terms of Use. The website from which you are linking, or on which you make certain content available, must comply in all respects with the Content Standards set out in these Terms of Use. You agree to cooperate with us in causing any unauthorized framing or linking immediately to stop. We reserve the right to withdraw linking permission without notice. We may disable all or any social media features and any links at any time without notice in our discretion.

  • Technical Safeguards 1. USAC and the Department will process the data matched and any data created by the match under the immediate supervision and control of authorized personnel to protect the confidentiality of the data, so unauthorized persons cannot retrieve any data by computer, remote terminal, or other means.

  • Innovative Scheduling Schedules which are inconsistent with the Collective Agreement provisions may be developed in order to improve quality of working life, support continuity of resident care, ensure adequate staffing resources, and support cost-efficiency. The parties agree that such innovative schedules may be determined locally by the Home and the Union subject to the following principles:

  • Technical Standards Applicable to a Wind Generating Plant i. Low Voltage Ride-Through (LVRT) Capability A wind generating plant shall be able to remain online during voltage disturbances up to the time periods and associated voltage levels set forth in the standard below. The LVRT standard provides for a transition period standard and a post-transition period standard.

  • Technical Specifications The Technical Specifications furnished on the CD are intended to establish the standards for quality, performance and technical requirements for all labor, workmanship, material, methods and equipment necessary to complete the Work. When specifications and drawings are provided or referenced by the County, these are to be considered part of the Scope of Work, and to be specifically documented in the Detailed Scope of Work. For convenience, the County supplied specifications, if any, and the Technical Specifications furnished on the CD.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!