Monitoring Systems and Adjustment of the Array Sample Clauses

Monitoring Systems and Adjustment of the Array. A description of the proposed current and phase monitoring system, including the electrical components and physical design details with a specific evaluation of the ultimate accuracy of the system in detecting changes in current amplitudes or phase relationships, specifically, that the phase/current sampling lines for the antenna monitor have identical physical and electrical characteristics, a low temperature/phase coefficient and have equal lengths subject to the same environmental conditions is required. In particular, the manufacturer, model number, resolution, and accuracy of the antenna monitor shall be specified. Sample current devices used to feed the antenna monitor shall be installed at or near the current maximum of each tower of the array. A statement should be included specifying the tolerance limits within which the operation parameters (amplitude and phase) will be maintained. An analysis to determine what levels of system deviation would cause radiation to exceed notified values in any direction toward the other country must be submitted. The monitoring system must be capable of detecting system deviations equal to or less than half of those which would result in radiation which would exceed the proposed or notified values. The proposed procedure for monitoring the radiation pattern in the field shall be described and the location of the monitoring points shall be specified. Monitoring points shall be located mainly at azimuths of minimum radiation (nulls) and shall have to adequately monitor the actual radiation pattern of the proposed station toward the other country. Based on the proof of performance, maximum limits of measured field strengths at these monitoring points should be established to assure maintenance of the actual radiation pattern within notified radiation limits toward the other country. The frequency of measurements at these monitoring points shall be at least weekly during the first month of station operation and at least monthly thereafter. When monitoring point field strength or operating parameter values in excess of the tolerance limits described above are observed, the station concerned shall immediately reduce power or readjust the array to restore radiation to within authorized limits. Except for emergency operation, testing, maintenance or other temporary operation, full power operation shall not resume until the array has been properly readjusted.
AutoNDA by SimpleDocs

Related to Monitoring Systems and Adjustment of the Array

  • Monitoring and Adjusting Forecasts Verizon will, for ninety (90) days, monitor traffic on each trunk group that it establishes at ECI’s suggestion or request pursuant to the procedures identified in Section 14.2 of this Attachment. At the end of such ninety-(90) day period, Verizon may disconnect trunks that, based on reasonable engineering criteria and capacity constraints, are not warranted by the actual traffic volume experienced. If, after such initial ninety (90) day period for a trunk group, Verizon determines that any trunks in the trunk group in excess of two (2) DS1s are not warranted by actual traffic volumes (considering engineering criteria for busy Centium Call Second (Hundred Call Second) and blocking percentages), then Verizon may hold ECI financially responsible for the excess facilities and disconnect such excess facilities.

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

  • Program Monitoring and Evaluation (c) The Recipient shall prepare, or cause to be prepared, and furnish to the Association not later than six months after the Closing Date, a report of such scope and in such detail as the Association shall reasonably request, on the execution of the Program, the performance by the Recipient and the Association of their respective obligations under the Legal Agreements and the accomplishment of the purposes of the Financing.”

  • Project Monitoring Reporting Evaluation A. The Project Implementing Entity shall monitor and evaluate the progress of its activities under the Project and prepare Project Reports in accordance with the provisions of Section 5.08(b) of the General Conditions and on the basis of indicators agreed with the Bank. Each such report shall cover the period of one

  • Project Monitoring Reporting and Evaluation The Recipient shall furnish to the Association each Project Report not later than forty-five (45) days after the end of each calendar semester, covering the calendar semester.

  • Implementation of the Agreement Regulations of this Agreement relating to investments who investors of one Contracting Party realized before or after the entry into force of this Agreement, with what shall apply from the moment of its entry into force, provided that such investments conducted in accordance with the laws of that Party Contracting.

  • Long Term Cost Evaluation Criterion # 4. READ CAREFULLY and see in the RFP document under "Proposal Scoring and Evaluation". Points will be assigned to this criterion based on your answer to this Attribute. Points are awarded if you agree not i ncrease your catalog prices (as defined herein) more than X% annually over the previous year for years two and thr ee and potentially year four, unless an exigent circumstance exists in the marketplace and the excess price increase which exceeds X% annually is supported by documentation provided by you and your suppliers and shared with TIP S, if requested. If you agree NOT to increase prices more than 5%, except when justified by supporting documentati on, you are awarded 10 points; if 6% to 14%, except when justified by supporting documentation, you receive 1 to 9 points incrementally. Price increases 14% or greater, except when justified by supporting documentation, receive 0 points. increases will be 5% or less annually per question Required Confidentiality Claim Form Required Confidentiality Claim Form This completed form is required by TIPS. By submitting a response to this solicitation you agree to download from th e “Attachments” section, complete according to the instructions on the form, then uploading the completed form, wit h any confidential attachments, if applicable, to the “Response Attachments” section titled “Confidentiality Form” in order to provide to TIPS the completed form titled, “CONFIDENTIALITY CLAIM FORM”. By completing this process, you provide us with the information we require to comply with the open record laws of the State of Texas as they ma y apply to your proposal submission. If you do not provide the form with your proposal, an award will not be made if your proposal is qualified for an award, until TIPS has an accurate, completed form from you. Read the form carefully before completing and if you have any questions, email Xxxx Xxxxxx at TIPS at xxxx.xxxxxx@t xxx-xxx.xxx Choice of Law clauses with TIPS Members If the vendor is awarded a contract with TIPS under this solicitation, the vendor agrees to make any Choice of Law c lauses in any contract or agreement entered into between the awarded vendor and with a TIPS member entity to re ad as follows: "Choice of law shall be the laws of the state where the customer resides" or words to that effect. 5 Agreed Venue of dispute resolution with a TIPS Member In the event of litigation or use of any dispute resolution model when resolving disputes with a TIPS member entity a s a result of a transaction between the vendor and TIPS or the TIPS member entity, the Venue for any litigation or ot her agreed upon model shall be in the state and county where the customer resides unless otherwise agreed by the parties at the time the dispute resolution model is decided by the parties. Agreed

  • Implementation of the Report 1. The Panel report shall be final and binding on the disputing Parties. 2. If the report issued by the Panel determines that a Party has not conformed with its obligations under this Agreement, the Party complained against shall eliminate the non- conformity. 3. The Party complained against shall comply with the recommendation of the Panel promptly or, if not practicable, within a reasonable period of time. The Parties shall agree on reasonable period of time within 30 days of the notification of the report of the Panel. In any case, such reasonable period of time shall not exceed 300 calendar days after the release of the report.

  • Technical Standards Applicable to a Wind Generating Plant i. Low Voltage Ride-Through (LVRT) Capability A wind generating plant shall be able to remain online during voltage disturbances up to the time periods and associated voltage levels set forth in the standard below. The LVRT standard provides for a transition period standard and a post-transition period standard.

  • Number Resources, Rate Center Areas and Routing Points 13.1 Nothing in this Agreement shall be construed to limit or otherwise adversely affect in any manner either Party’s right to employ or to request and be assigned any Central Office Codes (“NXX”) pursuant to the Central Office Code Assignment Guidelines and any relevant FCC or Commission orders, as may be amended from time to time, or to establish, by Tariff or otherwise, Rate Center Areas and Routing Points corresponding to such NXX codes.

Time is Money Join Law Insider Premium to draft better contracts faster.