MSP Trading Location Sample Clauses

MSP Trading Location. Product Specification for Balance-of-Day Physical Gas for Delivery at the MSP Trading Location MAP Trading Location Product Specification for Weekly Physical Gas for Delivery at the MAP Trading Location
AutoNDA by SimpleDocs
MSP Trading Location. In accordance with Australian Standard AS 4564-2005 – Specification for general purpose natural gas.
MSP Trading Location. As notified by the Transporter to MSP gas shippers from time to time, but no greater than 9,600 kPa. Schedule 4: Product Specifications for Daily Gas (Wallumbilla) Commodity Gas complying with the Gas Specification. Last Trading Date 27 March 2017 Gas Day commencement 8:00am AEST Delivery Period One Gas Day. Delivery Point The RBP Trading Location, at the Delivery Point specified in the Order, being one of the following: Run 3 Run 4 Run 7 RBP In Pipe Trade Point, as defined in schedule 2 for the RBP Trading Location. Trading Window For Gas Day D, Trading Hours on each of Gas Day D-7 to Gas Day D-2. For a Pre-matched Trade where the Trading Participants have specified that Delivery Netting is not to apply, the Trading Window for Gas Day D are Trading Hours on each of Gas Day D-30 to Gas Day D-2. Parcel Size 1000 GJ (1 TJ) Price The price is to be expressed in dollars per GJ. Product Limits Minimum Price: $-100/GJ Maximum Price $999/GJ Maximum Quantity 50,000 GJ (50 TJ) Unit GJ Admission to trade Automatic Gas Specification The gas specification applicable to the Delivery Point as determined in accordance with schedule 2. Flow Rate Even flow rate through the Delivery Period. Pressure The pressure range applicable to the Delivery Point as determined in accordance with schedule 2. Partial acceptance of Orders Permitted if specified in the Order. Minimum Transaction Quantity 1000 GJ (1 TJ) unless a larger number is specified in the Order. Expiry Time Unless an earlier time is specified in the Order, an Order for Gas Day D expires at the end of the Trading Window. Automatic withdrawal Applicable to open Orders at the end of each trading day after 5:00pm. Order Quantity to be displayed The whole of the Order Quantity will be displayed unless otherwise specified in the Order. Delivery Netting Applicable Pre-matched Trades Permitted. Trading Participants may specify that Delivery Netting is not to apply to a Pre-matched Trade (see clause 13.2(a2) of this agreement). If the Trading Participants have specified that Delivery Netting is not to apply to the Pre-matched Trade, the Trading Participants may also specify that the delivery point for the Pre-matched Trade is a delivery point agreed between the Trading Participants that is not specified in a Product Specification (alternate delivery point). If the Trading Participants have specified that Delivery Netting is not to apply to the Pre-matched Trade, the Parcel Size and the Minimum Transaction Quantity is 100GJ. Sp...
MSP Trading Location. Product Specification for On-the-Day Physical Gas for Delivery at the MSP Trading Location Product Specification for Day Ahead Netted Physical Gas Spread Product (SEQ-Wallumbilla) Product Specification for Day Ahead Non-Netted Physical Gas Spread Product (SEQ-Wallumbilla) Product Specification for Day-Ahead Netted Gas Spread Product (Moomba-Wallumbilla) Product Specification for Day Ahead Non-Netted Physical Gas Spread Product (Moomba-Wallumbilla)
MSP Trading Location. Product Specification for On-the-Day Physical Gas for Delivery at the MSP Trading Location

Related to MSP Trading Location

  • Shares Listed on Trading Market The Shares shall have been listed and admitted and authorized for trading on the Trading Market, and satisfactory evidence of such actions shall have been provided to the Manager.

  • Signaling Link Transport 9.2.1 Signaling Link Transport is a set of two or four dedicated 56 kbps transmission paths between Global Connection-designated Signaling Points of Interconnection that provide appropriate physical diversity.

  • Originating Switched Access Detail Usage Data A category 1101XX record as defined in the EMI Telcordia Practice BR-010-200- 010.

  • Wire Unbundled DS1 Digital Loop This is a designed 4-wire Loop that is provisioned according to industry standards for DS1 or Primary Rate ISDN services and will come standard with a test point, OC, and a DLR. A DS1 Loop may be provisioned over a variety of loop transmission technologies including copper, HDSL-based technology or fiber optic transport systems. It will include a 4-Wire DS1 Network Interface at the End User’s location.

  • Trading Facilities Most open-outcry and electronic trading facilities are supported by computer-based component systems for the order-routing, execution, matching, registration or clearing of trades. As with all facilities and systems, they are vulnerable to temporary disruption or failure. Your ability to recover certain losses may be subject to limits on liability imposed by the system provider, the market, the clearing house and/or member firms. Such limits may vary; you should ask the firm with which you deal for details in this respect.

  • Unbundled Digital Loops 2.3.1 BellSouth will offer Unbundled Digital Loops (UDL). UDLs are service specific, will be designed, will be provisioned with test points (where appropriate), and will come standard with OC and a DLR. The various UDLs are intended to support a specific digital transmission scheme or service. 2.3.2 BellSouth shall make available the following UDLs, subject to restrictions set forth herein:

  • Unbundled Copper Loop – Non-Designed (UCL-ND 2.4.3.1 The UCL–ND is provisioned as a dedicated 2-wire metallic transmission facility from BellSouth’s Main Distribution Frame to a customer’s premises (including the NID). The UCL-ND will be a “dry copper” facility in that it will not have any intervening equipment such as load coils, repeaters, or digital access main lines (“DAMLs”), and may have up to 6,000 feet of bridged tap between the end user’s premises and the serving wire center. The UCL-ND typically will be 1300 Ohms resistance and in most cases will not exceed 18,000 feet in length, although the UCL-ND will not have a specific length limitation. For loops less than 18,000 feet and with less than 1300 Ohms resistance, the loop will provide a voice grade transmission channel suitable for loop start signaling and the transport of analog voice grade signals. The UCL-ND will not be designed and will not be provisioned with either a DLR or a test point. 2.4.3.2 The UCL-ND facilities may be mechanically assigned using BellSouth’s assignment systems. Therefore, the Loop Make Up process is not required to order and provision the UCL-ND. However, Lightyear can request Loop Make Up for which additional charges would apply. 2.4.3.3 At an additional charge, BellSouth also will make available Loop Testing so that Lightyear may request further testing on the UCL-ND. Rates for Loop Testing are as set forth in Exhibit B of this Attachment. 2.4.3.4 UCL-ND loops are not intended to support any particular service and may be utilized by Lightyear to provide a wide-range of telecommunications services so long as those services do not adversely affect BellSouth’s network. The UCL-ND will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the loop to the customer’s inside wire. 2.4.3.5 Order Coordination (OC) will be provided as a chargeable option and may be utilized when the UCL-ND provisioning is associated with the reuse of BellSouth facilities. Order Coordination -Time Specific (OC-TS) does not apply to this product. 2.4.3.6 Lightyear may use BellSouth’s Unbundled Loop Modification (ULM) offering to remove bridge tap and/or load coils from any loop within the BellSouth network. Therefore, some loops that would not qualify as UCL-ND could be transformed into loops that do qualify, using the ULM process.

  • Trading Cushion The Selling Period for any previous Issuance Notice shall have expired.

  • Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Xxxx has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Xxxx. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Xxxx (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Xxxx, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Xxxx will then have the option of paying the one-time SC rates to place the Loop.

  • TRADING HOURS In accordance with the valid customs for trading Crypto Assets, there are no restrictions on trading hours in the Crypto Transactions at Trade Republic, except for blocking periods due to maintenance work. During the respective periods of maintenance work, trading of Crypto Assets is not possible. The maintenance periods are shown in the Application. Therefore, the Customer must be aware that trading cannot be guaranteed continuously. The trading hours with Crypto Assets have no influence on the trading hours of other asset classes at Trade Republic, which can be retrieved on the Trade Republic Website or in the Application.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!