Overshots Sample Clauses

Overshots. Quantity 1 Make/Type NOV-Xxxxx S-150 Overshot OD 11.750” To catch size (Max Catch Spiral Grapple) 10 1/8” To catch size (Max Catch Size Basket Grapple) 9 3/8” To catch size Overshot guide OD 11.750” & 17.50” Extension sub length 36” Extension sub length 48” Lipped guide (oversize, regular) Oversize & Regular Grapples (spiral, basket, both) yes/no: Both Pack offs Yes Top sub connection type 6 5/8” API Reg Box Quantity 1 Make/Type NOV-Xxxxx S-150 Overshot OD 8.125 To catch size (Max Catch Spiral Grapple) 6 1/2” To catch size (Max Catch Size Basket Grapple) 5 3/4” To catch size Overshot guide OD 8 1/8” Extension sub length 36” Lipped guide (oversize, regular) Regular Grapples (spiral, basket, both) Both Pack offs Yes Top sub connection type 4 1/2” IF Box Quantity 1 Make/Type NOV-Xxxxx S-150 Overshot OD 8.125 To catch size (Max Catch Spiral Grapple) 7” To catch size (Max Catch Size Basket Grapple) 6 3/8” To catch size Overshot guide OD 8 1/8” Extension sub length 42” Extension sub length 36” Lipped guide (oversize, regular) Regular Grapples (spiral, basket, both) Both Pack offs Yes Top sub connection type 4 1/2” IF Box
AutoNDA by SimpleDocs
Overshots. Quantity: no. 1 Make/type: Xxxxx 150 FS Overshot OD: in 11 ¾ To catch size: in 4 7/8 to 10 1/8 Overshot guide OD: in 11 ¾ Extension sub length: in 36 , 60 Lipped guide (oversize, Regular): 15” , 22” Grapples (spiral, basket, both): To fish contractor’s new + used tubelars Pack offs: yes/no Yes Top sub connection type: 6 5/8” Reg Box Quantity: no. 1 Make/type: Xxxxx 150 FS Overshot OD: in 9 5/8 To catch size: in 4 7/8 to 8 Overshot guide OD: in 9 5/8 Extension sub length: in 36 , 48 Lipped guide (oversize, Regular): 15” Grapples (spiral, basket, both): To fish contractor’s new + used tubelars Pack offs: yes/no yes Top sub connection type: 6 5/8 Reg Box Quantity: no. 1 Make/type: Xxxxx 150 SH Overshot OD: in 8 1/8 To catch size: in 4 7/8 to 7 Overshot guide OD: in 8 1/8 Extension sub length: in 42 Lipped guide (oversize, Regular): Standard 8 1/8” Grapples (spiral, basket, both): Spiral 7”, 6 7/8”, 6 ¾”, 6 5/8” Pack offs: yes/no Yes Top sub connection type: 4 ½ IF Box Quantity: no. 1 Make/type: Xxxxx 150 FS Overshot OD: in 7 7/8 reinforced to 8 1/8 ( FS) To catch size: in 4 7/8 to 6 3/4 Overshot guide OD: in 8 1/8 Extension sub length: in 42 Lipped guide (oversize, Regular): Grapples (spiral, basket, both): To fish contractor’s new + used tubelars Pack offs: yes/no Yes Top sub connection type: 4 ½ IF Box
Overshots. Quantity: no. 1 Make/type: Xxxxx 150 FS Overshot OD: in 11 3/4” To catch size: in 4 7/8” to 10 1/8 “ Overshot guide OD: in 11 3/4” Extension sub length: ft 3 ft , 4ft, 5 ft Lipped guide (oversize, regular): 15” , 21” , 42” Grapples (spiral, basket, both): Both Pack offs: yes/no Yes Top sub connection type: 6 5/8” REG Quantity: no. 1 Make/type: Xxxxx 150 FS Overshot OD: in 9 5/8” To catch size: in 4 7/8” to 8” Overshot guide OD: in 9 5/8” CONFIDENTIAL TREATMENT REQUESTED. INFORMATION FOR WHICH CONFIDENTIAL TREATMENT HAS BEEN REQUESTED IS OMITTED AND MARKED WITH “[***]”. AN UNREDACTED VERSION OF THE DOCUMENT HAS ALSO BEEN FURNISHED SEPARATELY TO THE SECURITIES AND EXCHANGE COMMISSION AS REQUIRED BY RULE 24B-2 UNDER THE SECURITIES EXCHANGE ACT OF 1934, AS AMENDED. Extension sub length: ft 3 ft, 4 ft, 5 ft Lipped guide (oversize, regular): 11” , 15” 21” Grapples (spiral, basket, both): Both Pack offs: yes/no Yes Top sub connection type: 6 5/8” REG
Overshots. Quantity no.: 1 Make/Type : F.S Top sub connection type : 6 5/8 Reg Overshot OD inch: 11 3/4” Max catch size inch: 9 1/2” To catch size Spiral grapple inch: 9.1/2 9 3/8,8 1/2,8 3/8,8 1/4,8 1/8,7 1/4,7 1/8,7, 6 7/8, 6 5/8,6 To catch size Basket grapple Control rings Extension sub length inch: ft: 1/2, 6 3/8, 5 1/2, 5 For above grapples 2.5 Lipped guide (oversize, regular) “: 113/4,15, 21 Quantity no.: 1 Make/Type : TBA S.H Series 150 Top sub connection type : 4 IF Overshot OD inch: 8.3/8 Max catch size inch: 7 1/4” To catch size Spiral grapple inch: 7 1/4, 7 1/8, 7, 6 7/8, To catch size Basket grapple Control rings Extension sub length inch: ft: 6 5/8, 6 1/2, 6 3/8, 5 1/2, 5 For above grapples 2.5 Lipped guide (oversize, regular) : 8 3/8, 11,

Related to Overshots

  • Design At no cost to SCE, Seller shall be responsible for:

  • Configuration The configuration for the Purchase Right Aircraft will be the Detail Specification for Model 767-3S2F aircraft at the revision level in effect at the time of the Supplemental Agreement. Such Detail Specification will be revised to include (i) changes required to obtain required regulatory certificates and (ii) other changes as mutually agreed upon by Boeing and Customer.

  • Compatibility 1. Any unresolved issue arising from a mutual agreement procedure case otherwise within the scope of the arbitration process provided for in this Article and Articles 25A to 25G shall not be submitted to arbitration if the issue falls within the scope of a case with respect to which an arbitration panel or similar body has previously been set up in accordance with a bilateral or multilateral convention that provides for mandatory binding arbitration of unresolved issues arising from a mutual agreement procedure case.

  • Programming (a) Pursuant to Section 624 of the Cable Act, the Licensee shall maintain the mix, quality and broad categories of Programming set forth in Exhibit 4, attached hereto and made a part hereof. Pursuant to applicable federal law, all Programming decisions, including the Programming listed in Exhibit 4, attached hereto, shall be at the sole discretion of the Licensee.

  • XXXREAS the Trust is registered under the Investment Company Act of 1940, as amended, (the "1940 Act") as an open-end, series management investment company; and

  • Interfaces Bellcore’s GR-446-CORE defines the interface between the administration system and LIDB including specific message formats. (Bellcore’s TR-NWP-000029, Section 10)

  • Commissioning Commissioning tests of the Interconnection Customer's installed equipment shall be performed pursuant to applicable codes and standards. If the Interconnection Customer is not proceeding under Section 2.3.2, the Utility must be given at least ten (10) Business Days written notice, or as otherwise mutually agreed to by the Parties, of the tests and may be present to witness the commissioning tests.

  • Sprinkler System If there now is or shall be installed in the Building a "sprinkler system", and such system or any of its appliances shall be damaged or injured or not in proper working order by reason of any act or omission of Tenant, Tenant's agents, servants, employees, licensees or visitors, Tenant shall forthwith restore the same to good working condition at its own expense; and if the New York Board of Fire Underwriters or the New York Fire Insurance Rating Organization or any bureau, department or official of the state or city government, shall require or recommend that any changes, modifications, alterations or additional sprinkler heads or other equipment be made or supplied by reason of Tenant's business, or the location of the partitions, trade fixtures, or other contents of the Premises, Tenant shall, at Tenant's expense, promptly make and supply such changes, modifications, alterations, additional sprinkler heads or other equipment.

  • Engineering Forest Service completed survey and design for Specified Roads prior to timber sale advertisement, unless otherwise shown in A8 or Purchaser survey and design are specified in A7. On those roads for which Forest Service completes the design during the contract, the design quantities shall be used as the basis for revising estimated costs stated in the Schedule of Items and adjusting Timber Sale Account. Forest Service engineering shall be completed according to the schedule in A8. Should Forest Service be unable to perform the designated survey and design by the completion date or other agreed to time, upon written agreement, Purchaser shall assume responsibility for such work. In such event, Contracting Officer shall revise:

  • Site Lands or areas indicated in the Contract Documents as being furnished by the Owner upon which the Work is to be performed, including rights-of-way and easements for access thereto, and such other lands furnished by the Owner that are designated for the use of the Contractor. Also referred to as Project Site, Job Site and Premises.